Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 68 for “"Pressure Estimation"”.
-
Cuffless Blood Pressure Estimation Using Cardiovascular Dynamics
Blood pressure (BP) monitoring is an important tool for management of hypertension, which is a significant risk for cardiovascular disease and premature death. Since cuff-based BP measurement can be uncomfortable and does not provide continuous readings, several cuffless methods that are typically …
-
Blood Pressure Estimation Using Oscillometric Pulse Morphology
… presents the analysis of Oscillometric blood pressure pulse waveform under different pressure points (Systolic, Mean Arterial, and Diastolic Pressures). Pulse waveforms' characteristics were determined from the waveforms at three different pressures and are compared for subjects at three …
-
Ratio-Independent Arterial Stiffness-Based Blood Pressure Estimation
Blood pressure is one of the crucial vital signs that still lacks measurement accuracy in clinical environments. It is reported by physicians that automated non-invasive blood pressure measurement devices, which are usually based on the oscillometric method, do not provide accurate estimation of …
-
Cuff-free blood pressure estimation using signal processing techniques
Since blood pressure is a significant parameter to examine people's physical attributes and it is useful to indicate cardiovascular diseases, the measurement/estimation of blood pressure has gained increasing attention. The continuous, cuff-less and non-invasive blood pressure estimation is …
-
Non-invasive relative pressure estimation using 4D PC-MRI
… work demand of the heart. In this scenario, the pressure drop through a vascular obstruction is a biomarker adopted in clinical guidelines for the management of several disease conditions, such as aortic coarctation and valvular stenosis. While extensively used clinically, current methods and …
-
A General Model for Continuous Noninvasive Pulmonary Artery Pressure Estimation
Elevated pulmonary artery pressure (PAP) is a significant healthcare risk. Continuous monitoring for patients with elevated PAP is crucial for effective treatment, yet the most accurate method is invasive and expensive, and cannot be performed repeatedly. Noninvasive methods exist but are …
-
Towards Accurate Cuffless Blood Pressure Estimation with Reduced Calibration Requirements
Cuffless Blood Pressure (BP) estimation using Electrocardiogram (ECG) and Photoplethysmogram (PPG) features is a promising alternative to cuff-based devices for continuous BP monitoring. However, its practical deployment faces several critical challenges: Respiration Modulation (RM) introduces …
-
A Modeling Approach for Coefficient-Free Oscillometric Blood Pressure Estimation
… measurement method used in automatic blood pressure (BP) monitors. However, most of the oscillometric algorithms are without physiological and theoretical foundation, and rely on empirically derived coefficients for systolic and diastolic pressure evaluation which affects the reliability of …
-
Improving Algorithms for Oscillometric Blood Pressure Estimation by Suppressing Breathing Effects
Blood pressure estimation by the oscillometry is a practice growing in popularity. Algorithms for blood pressure estimation are diverse, however little effort has been put forth to assess their performance. This thesis first surveys and assesses the algorithms used for oscillometric blood pressure …
-
Linear regression model for continuous non-invasive blood pressure estimation for an ICU setting
Continuous blood pressure (BP) monitoring in critically ill patients is crucially important for clinicians. The gold standard intra-arterial method is complicated and contraindicated. Current pulse transit time (PTT)-based BP estimation methods are validated on healthy subjects using intermittent …
-
Deep Learning Applications in Health Informatics: Cuffless Blood Pressure Estimation and Synthetic Melanoma Image Generation
… clinical applications: cuffless blood pressure monitoring from photoplethysmography (PPG) and synthetic melanoma image generation to address class imbalance in skin cancer detection. The first study introduces the Normal Blood Pressure Database (NBPDB), a curated benchmarking subset of …
-
An Integrated Compensation System Based on Empirical Mode Decomposition for Robust Noninvasive Blood Pressure Estimation
… accuracy is not a choice. Accuracy in blood pressure (BP) estimation is essential for proper diagnosis and management of hypertension. An error of 5 mmHg is so serious, it can be responsible for doubling or halving number of patients diagnosed with hypertension. Motion artifacts are external …
-
Investigation of Machine-Learning Techniques for Pulmonary Artery Pressure Estimation from Electrical Impedance Tomography Images
Pulmonary artery pressure (PAP) is measured for the diagnosis and monitoring of pathologies such as congestive heart failure. Unfortunately, current modalities used for PAP measurements have disadvantages which reduce their use. One proposal to address these issues is the measurement of PAP using a …
-
Blood Pressure Estimation through Photoplethysmography using Deep Learning in Clinical Setting: Critical Survey and Solutions
Current solutions for blood pressure monitoring can be classified as invasive or non-invasive, both with drawbacks. Invasive blood pressure monitoring can lead to complications. Non-invasive blood pressure monitoring is intermittent which leads to missed episodes of hypertension and hy- potension, …
-
Deep water Gulf of Mexico pore pressure estimation utilizing P-SV waves from multicomponent seismic in Atlantis Field
Overpressure, or abnormally low effective pressures, is hazardous in drilling operations and construction of sea-bottom facilities in deepwater environments. Estimation of the locations of overpressure can improve safety in these operations and significantly reduce overall project costs. …
-
From Morphology to Physiology: Limits of Data-Driven Learning and Physics-Informed Neural Networks for Cuffless Blood Pressure Estimation
L'abstract è presente nell'allegato / the abstract is in the attachment
Page 1 of 4