Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 81 for “"Pressure Signals"”.
-
Understanding Peripheral Blood Pressure Signals: A Statistical Learning Approach
… human and animal subjects using peripheral blood pressure (PBP) signals. Peripheral venous pressure (PVP) and peripheral arterial pressure (PAP) signals have been investigated in this research. Both PVP and PAP signals are PBP signals. A dataset of PVP signals was collected using standard …
-
Signal quality measures for pulse oximetry and blood pressure signals acquired in unsupervised home telecare environments
… errors can degrade the quality of the recorded signals and ultimately degrade the performance of the DSS system which is aiding the clinician in their management of the patient. This thesis focuses the development of algorithms capable of automatically assessing the quality of two physiological …
-
Characterization of the fluidization behavior of different solid types based on chaotic time series analysis of pressure signals
… to show that chaotic time series analysis of pressure-drop measurements can be used to distinguish the behavior patterns of four different fluidizing solids belonging to groups A, B, and D. The fluidizing solids included fluidizing cracking catalyst (group A), 35x100 mesh stainless steel …
-
From the classical analysis of the center of pressure signals to a novel approach: study of rotational components.
… body sway during upright standing. The Center-of-Pressure (CoP) signal is recorded by a force platform and analyzed according to different techniques. Traditional approaches decompose the CoP signal into antero-posterior (AP) and medio-lateral (ML) time series and extrapolate geometrical, …
-
Internal leakage diagnosis in valve controlled actuation systems and electrohydrostatic actuation systems
… based on the ratio of metric lengths of pressure signals, autocorrelation of pressure signal, cross correlation between chamber pressure signals, and cross correlation between control signal and piston displacement is employed for internal leakage diagnosis. For the VCA, autocorrelation …
-
Pressure Monitoring for Subsurface Leakage Characterization
… can remain undetected for a long period. Pressure monitoring is a dynamic method that can be used for leakage detection and characterization. The pressure signals are affected by the hydraulic characteristics of the reservoir media and leakage pathways. Consequently, the pressure data can …
-
Real-time Pipeline Burst Detection and Estimation using the Damping of Fluid Transients
… in the whole frequency range of the transient pressure signals that are measured by one sensor alone. Earlier research has shown that a pipeline leak can cause additional damping of the transient pressure signals. The additional damping exists in burst problems. Additionally, according to the …
-
Effect of Transducer Size on the Statistical Properties of a Simulated Turbulent Wall Pressure Field
The root mean square pressure was calculated with synthetically generated pressure signals for transducers of different size. The transducer diameters were in the range of 0.02 < s*of 12,250. The lower limit of the diameter simulated here was much smaller than diameters reported previously by other …
-
Experimental study on the hydrodynamics in the riser of a circulating fluidized bed.
… In this work, a pair of dual-stem differential pressure probes have been developed for the measurements of the differential pressure fluctuation in the axial direction of a dense, vertical gas-solid two phase pipe flow. The application of the statistical analysis to the differential pressure …
-
Proposta de algoritmo para detecção de vazamentos em oleodutos utilizando análise freqüencial de sinais de pressão
… obtained from frequency spectrum analysis of pressure signals from pipelines in several flowing conditions like normal flowing, leakages, pump switching, etc. The results show that is possible to distinguish between the frequency spectra of those different flowing conditions, allowing …
-
Bioengineering technologies to monitor movements in supported postures: a potential strategy to prevent pressure ulcers
… vulnerable areas, leading to the development of pressure ulcers (PUs). For several decades, interface pressure measuring systems have been employed to assess the magnitudes of pressures at the support surface interface of individuals at risk of developing PUs, typically to evaluate the short-term …
-
Aerodynamic performance of turbine rim sealing flows
… ex- amined rotor disc rotation, mainstream pressure asymmetries and unsteady structures in the cavity as main drivers. The facility underwent major modifications to allow different annulus flow configurations, higher resolution in the low and high bandwidth pressure instrumentation and the …
-
Hidden Markov approach for screenout detection in unconventional reservoirs, A
… pre-screenout patterns in the simulated surface pressure signals. The classification system consists of two Gaussian Hidden Markov Models (screenout and non-screenout), each of which is fitted and optimized by its respective training set. Both Hidden Markov Models are assigned with two 1D …
-
Extracting Cardiac Information From the Pressure Sensors of a Dialysis Machine
… using the built-in extracorporeal blood pressure sensors of a hemodialysis machine. Patients treated with hemodialysis often suffer from cardiovascular disease. Despite this, cardiac monitoring is not routinely performed during dialysis treatment, since external devises required for such …
-
Acoustic characteristics of Pyroclastic Density Currents : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Earth Science at Massey University, Palmerston North, New Zealand
… of understanding of how and where the infrasound signals recorded from PDCs are generated and what properties they are linked to. This thesis covers the use of large-scale analog experimental PDCs at the PELE facility (the Pyroclastic flow Eruption Large-scale Experiment) to constrain PDC …
-
Specialised Non-Invasive Blood Pressure Measurement Algorithm
Blood pressure is one of the fundamental clinical measures. For more than 100 years, clinicians and researchers have used the mercury sphygmomanometer for blood pressure measurement. Environmental concern about mercury contamination has highlighted the need to find a replacement for traditional …
-
Stall precursor determination of an LM-2500 gas turbine
… Specifically, the time series of three separate pressure signals located at stages 3, 6, and 15 were analyzed utilizing fast Fourier transform, power spectral density, and an autocorrelation technique to determine the best and most reliable indicator to stall. The spectral analyses performed …
-
Experimental investigation of unsteady fan flow interaction with downstream struts
Pressure signals were taken on a rotor blade surface of a single-stage, low-speed axial flow compressor. The data showed unsteady, stationary pressure perturbations that correlated with the locations of five large downstream support struts. In the present work, these data are thoroughly analysed. …
-
Understanding effect and diagnosis of internal leakage in hydrostatic actuation systems
… for detecting internal leakage. The original pressure signals at either side of the cylinder are decomposed using Wavelet transform to detect internal leakage which is clearly identified. Results obtained through the use of Wavelet transform prove that this method is fast and …
-
Efficient Detection of Road Surface Disruptions for Off-Road Mining Trucks
… for detecting road disruptions using truck strut pressure signals from multi-task sensors. By analyzing data from the vehicle controller, the method identifies maintenance needs and evaluates pothole dimensions and damage severity. A multi-platform application and human-machine interface are …
Page 1 of 5