Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 355 for “"Pressure Transducers"”.

  1. Fiber optic and laser digital pressure transducers.

    The theory and response of fiber optic pressure transducers were investigated in a continuation of previous research. A 0.125 inch diameter transducer was built and statically tested. A probe consisting of two concentric glass fiber bundles was used to transmit light to and from the transducer …

    nps Repository record for Fiber optic and laser digital pressure transducers. (opens in a new tab)

  2. Using Pressure Transducers for Noninvasive Heart and Respiratory Monitoring

    … heart and respiratory monitor (HARMONI). It uses pressure transducers and medical tubing placed on a person's chest. The tubing is plugged off at one end, and then attached to a pressure transducer at the other end. The transducer sees spikes in voltage whenever the pressure inside the tubing …

    vt Repository record for Using Pressure Transducers for Noninvasive Heart and Respiratory Monitoring (opens in a new tab)

  3. Dynamic response testing of transient pressure transducers for liquid propellant rocket combustion chambers

    … of the dynamic response of transient pressure transducers intended for use in liquid propel lant rocket combustion chambers was undertaken. Shock tube testing included optimization of operating techniques especially the tailored interface and the effects of ground shock and other …

    nps Repository record for Dynamic response testing of transient pressure transducers for liquid propellant rocket combustion chambers (opens in a new tab)

  4. Overcoming Thermal Challenges to Acquire Absolute Pressure Measurements in Rotating Detonation Engines Using Piezoresistive Pressure Transducers

    Presently, piezoelectric (PE) pressure transducers in a recessed configuration are used to acquire the time-varying pressure in rotating detonation engines (RDEs). In addition, the capillary tube averaged pressure (CTAP) configuration with a low-frequency transducer is used to obtain the …

    alabama Repository record for Overcoming Thermal Challenges to Acquire Absolute Pressure Measurements in Rotating Detonation Engines Using Piezoresistive Pressure Transducers (opens in a new tab)

  5. CHARACTERIZING THE HYDROGEOLOGIC PROPERTIES OF THICK CLAYSTONE AQUITARDS IN THE WILLISTON BASIN USING GROUTED-IN PRESSURE TRANSDUCERS

    … the measurement and interpretation of pore pressure responses recorded by grouted-in vibrating wire pressure transducers (VWPs). Ten VWPs were installed in one borehole to a total depth of 325 m BG near the northeastern portion of the Williston Basin (Site 1). The loading efficiency (γ) was …

    sask Repository record for CHARACTERIZING THE HYDROGEOLOGIC PROPERTIES OF THICK CLAYSTONE AQUITARDS IN THE WILLISTON BASIN USING GROUTED-IN PRESSURE TRANSDUCERS (opens in a new tab)

  6. Laboratory investigation of dense non-aqueous phase liquid migration and remediation in mixed wettability soils monitored by pressure transducers

    … via a waterflood followed by a surfactant flush. Pressure data recorded during the experiments confirmed that DNAPL will be drawn into NAPL-wet lenses and result in negative capillary pressures. The waterflood had little impact on the NAPL distribution. The surfactant flush did reduce the …

    carleton Repository record for Laboratory investigation of dense non-aqueous phase liquid migration and remediation in mixed wettability soils monitored by pressure transducers (opens in a new tab)

  7. Void fraction measurements in large (0.3 m) diameter bubble column using Wire Mesh Sensor and Pressure transducers- Effect of sparger

    … using Wire Mesh Sensor (WMS) tomography and Pressure Transducers. Pair of WMS sensors, with a 64×64 wire configuration of each sensor, were installed which are separated by a distance along the axis of the bubble column. Wire Mesh Sensors and PTs Data were collected for time-averaged and …

    cuny Repository record for Void fraction measurements in large (0.3 m) diameter bubble column using Wire Mesh Sensor and Pressure transducers- Effect of sparger (opens in a new tab)

  8. Void fraction measurements in a large (0.3 m) diameter bubble column using Wire Mesh Sensors and Pressure Transducers: Effect of Spargers

    … using Wire Mesh Sensor (WMS) tomography and Pressure Transducers. Pair of WMS sensors, with a 64×64 wire configuration of each sensor, were installed which are separated by a distance along the axis of the bubble column. Wire Mesh Sensors and PTs Data were collected for time-averaged and …

    cuny Repository record for Void fraction measurements in a large (0.3 m) diameter bubble column using Wire Mesh Sensors and Pressure Transducers: Effect of Spargers (opens in a new tab)

  9. The development of a controller for differential pressure calibrations

    <p>Pressure transducers are used to provide flight performance and tunnel conditions information during wind tunnel testing. All pressure transducers used during testing must have calibrations traceable to the National Institute of Standards and Technology (NIST); therefore, calibration is required …

    ut-knoxville Repository record for The development of a controller for differential pressure calibrations (opens in a new tab)

  10. Analysis of in-cylinder pressure transducer data quality utilizing a SIDI turbocharged engine

    In-cylinder pressure transducers have been used for decades to record combustion pressure inside a running engine. However, due to the extreme operating environment, transducer design and installation must be considered in order to minimize measurement error. One such error is caused by thermal …

    mtu Repository record for Analysis of in-cylinder pressure transducer data quality utilizing a SIDI turbocharged engine (opens in a new tab)

  11. Monitoring axial-flow compressors for rotating stall and surge

    … include, hot-wire anemometers, thermocouples, pressure transducers, strain gages, optical sensors, and acoustical sensors. Research is currently under way on using high response static pressure transducers to detect rotating stall before its inception, and shows some promise for the early …

    ut-knoxville Repository record for Monitoring axial-flow compressors for rotating stall and surge (opens in a new tab)

  12. Development of a data reduction method for a high frequency angle probe

    … tunnels. The probe measures time-resolved total pressure, static pressure, angle of attack, and yaw angle from readings of four pressure transducers. The unique feature of this probe, as compared to a conventional multi-hole directional probe, is that the four high frequency response silicon …

    vt Repository record for Development of a data reduction method for a high frequency angle probe (opens in a new tab)

  13. PRESSURE MEASUREMENTS INSIDE MULTIPLE CAVITIES OF A TORQUE CONVERTER AND CFD CORRELATION

    A torque converter was instrumented with 29 pressure transducers. The pressure transducers were located in multiple cavities. The instrumented cavities included, four transducers mounted on the impeller shell, on the channel between blades. Six transducers mounted on the pressure and suction sides …

    mtu Repository record for PRESSURE MEASUREMENTS INSIDE MULTIPLE CAVITIES OF A TORQUE CONVERTER AND CFD CORRELATION (opens in a new tab)

  14. Vacuum Integrity and Leak Localization in Polymer Composite Manufacturing

    … while the pump is operating, rather than from pressure measurements across the part. This thesis investigates whether a distributed array of pressure transducers installed beneath the vacuum film can localize a leak during the vacuum-drop test. Twenty pressure transducers recorded gauge …

    ottawa-retro Repository record for Vacuum Integrity and Leak Localization in Polymer Composite Manufacturing (opens in a new tab)

  15. Transient Maneuvers and Pressure Analysis on an Automotive Torque Converter

    … The fluid behavior is identified through 29 pressure transducers instrumented throughout the torus, acquired through IR Telemetrics multiplexed channels, and analyzed with custom MATLAB code. The main vehicle operating conditions studied in this research are back drive scenarios or low …

    mtu Repository record for Transient Maneuvers and Pressure Analysis on an Automotive Torque Converter (opens in a new tab)

  16. Measurement of synchronous forces and flow non-uniformity in an axial compressor

    Time resolved pressure measurements on a compressor case were acquired for several uniform and non-uniform tip clearances. High frequency response pressure transducers were placed at several axial locations near the second stage axial rotor on the outer casing of an Allison C-250 compressor. Data …

    nps Repository record for Measurement of synchronous forces and flow non-uniformity in an axial compressor (opens in a new tab)

Page 1 of 18