Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 52 for “"Pressure gauge"”
-
Extension of the range of the Moser and Poltz McLeod gauge from 10 ⁻¹⁰ to 10⁻² Torr
Two McLeod gauges of the Moser and Poltz type have been designed, assembled and used in experiments. The primary gauge constants (K) are: low pressure gauge (lpg) 7.66 x 10"^, medium pressure gauge (mpg) I .45 x I 0"?. With a limit for h of approximately 6 x 10“ mm, the theoretical low Iimit of the …
-
The Effect of particle shape on just-suspended speed of mixtures of solids at high concentrations
… experimentally by visual observation or pressure gauge measurement method. If the mixing system is at the design stage or if it is not possible to apply experimental methods, the correlations in literature are used to predict Njs. Most of the studies on this subject have been done with …
-
Pressure measurements during one-sided heating of concrete
… The spalling may be caused by increasing vapor pressures in the pores of the concrete. The experiments discussed in this report are the first to combine temperature and pressure measurements with 1D-moisture profiles, during the heating of concrete. For this, cylindrical concrete (W/C=0.54) …
-
Analysis of water level measurements using GPS
… including the use of different types of gauges (e.g., water level gauge or tide gauge, and bottom pressure gauge), as well as GPS and satellite altimetry. The GPS water level measurements from a buoy or a vessel are presented and utilized in this study along with other techniques to …
-
An investigation into the effect of the gilding jacket on 12.7 mm armour-piercing projectile penetration of armour materials
… The results of these experiments, backed by a pressure-gauge based impact technique, were validated via numerical modelling. It was observed that the jacket appears to serve three inter-linked functions: pre-damage of the target; cushioning of the AP core and confinement of the core. Modifying …
-
The comparison of gaseous densities by the method of balancing columns, with applications.
… as in fig. 1 (Drovision being made that the pressure is the same at the tops of the two columns), then the difference in density of the gases will produce a difference in the hydrostatic pressure at the bases of the columns. Or, conversely, we can say that the reading of a suitable pressure …
-
A Hydrostatic Pressure Perfusion System for Biological Systems
A hydrostatic pressure perfusion system with two closed fluid reservoirs has been constructed and characterized. The system utilizes two stainless steel pressure generators connected to gearheads. Stepper motors are connected to the gearheads and are used to provide constant fluid flow throughout …
-
Case study of a flowfield using a pentode
<p>A pentode vacuum-tube, used as a fast-response pressure-gauge, was found to be well suited for measuring gas pulses into a vacuum chamber through a sonic orifice. Static and dynamic calibration curves with fitted equations are presented for nitrogen and carbon dioxide. Placement of a skimmer …
-
Comparison of measured and transformed directional wave spectra using linear refraction model.
… spectra are compared with measured spectra using pressure gauge arrays in shallow water at Marina and Santa Cruz. Refraction (Kr) , shoaling (Ks) and Jacobian (J) transfer functions are computed. The modeling results and measured wave data at Marina are in good agreement for easterly waves at high …
-
Pressure induced phase transitions in copper (I) oxide and copper (II) oxide.
We have studied samples of CuO and Cu$\sb2$O to pressures of 60 GPa and 35 GPa, respectively, using energy dispersive X-ray diffraction. Samples were studied using a gasketed diamond anvil cell, energy dispersive X-ray diffraction at the Cornell High Energy Synchrotron Source, with a Mo or …
-
Examination of laser-produced pressure pulses in a gallium arsenide solar cell.
Pressure pulses caused by irradiation of a model gallium arsenide solar cell with a Carbon Dioxide TEA Laser were examined using power densities of the order of 10 7 watts/cm2 . The pressure pulses were monitored with a Sandia type quartz pressure gauge. It was discovered that the relatively low …
-
Estimação e compensação da influência da temperatura do gás manométrico em um sensor de pressão: um estudo de caso usando sensor piezoresistivo
… with the need for temperature compensation in a pressure sensor. One motivation for this work is the cheap of pressure sensors as secondary standards instead of a more expensive the Digital Pressure Gauge (DPG). The output of such sensors, however, are influenced by the manometric gas …
-
Diseño y construcción de un marco de carga metálico para ensayos de flexión en vigas de concreto y tensión diagonal en muretes de mampostería
… The tests are demonstrative in nature, since the pressure-gauge readings are indicative in the absence of a load cell. The outcome is a safe, versatile and low-cost apparatus for teaching and applied research.
-
Fabrication and study of micro-bubble generator
… head were significant parameters while pressure and orifice diameter did not have major impact at the given range. Further observations show that the pressure inputs were out of range, and a better pressure gauge was required for future experiments. It was found that there was a critical …
-
Estimating ocean wave directional spectra from measurements of water particle motion by a surface buoy acoustic ranging system
… data obtained from a commercial bottom mounted pressure gauge serve as a reference for comparing water particle displacement measurements recorded by the instrumentation system. Similarly, aerial photographs taken of the wave field in the study area during the experiment were used as a reference …
-
The dielectric constant of disulfur decafluoride, and high pressure instrumentation at high temperatures.
… stable non polar dielectric. Part II - High Pressure Instrumentation At High Temperatures. Four reliable instruments for P-V-T measurements on gases at 100 atmospheres and 1500ºc. have been developed: i - A furnace temperature controller for the range 150 to 1500ºc., accurate to 0.1ºc.; ii - …
-
Comparison of measured and transformed directional wave spectra using a linear refraction model
… spectra are compared with measured spectra using pressure gauge arrays in shallow waters at Marina and Santa Cruz. The classical Longuet-Higgins et al. (1963) method of computing directional wave spectra and a new exact Founrier coefficients representation method (Grauzinis, 1989) are used to …
-
Investigation of Blast–related Fluid Cavitation using a Novel Polymeric Hopkinson Bar–Confinement Chamber Apparatus
… exposure studies is the negative intracranial pressure occurring at the opposite site of initial blast wave transmission. This observation resulted in the hypothesis of intracranial cavitation of cerebrospinal fluid (CSF), due to the negative pressures generated, as a potential brain injury …
-
Pressures exerted by elastic wraps applied by beginning and advanced student athletic trainers to the ankle and the thigh with and without an ice pack.
… and without ice, to study the application of pressure and consistency of application. Subjects were 23 beginning and 23 advanced student athletic trainers (12 males, 11 females in each group). Pressures exerted over the anterior thigh and the anterior talc-fibular ligament were measured with a …
-
Some molecular-beam measurements with a Pirani detector
… With a circular entrance channel of pressure-accumulation factor 28, at room temperature a one-microvolt signal was produced for a helium beam intensity of 5.4 x 10¹² atoms/sec/cm² . At liquid-nitrogen temperature, the sensitivity increased almost four times. This detector was used to …
Page 1 of 3