Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 33 for “"Prestressed concrete structures"”.

  1. FINITE ELEMENT METHOD FOR POST-TENSIONED PRESTRESSED CONCRETE STRUCTURES

    … approaches for modeling post-tensioned (PT) prestressed concrete structures via the finite element method (FEM). The challenge of modeling PT prestressed concrete structures lies in the treatment of the interface between the concrete and prestressing tendons. The generic modeling techniques …

    oklahoma-thes Repository record for FINITE ELEMENT METHOD FOR POST-TENSIONED PRESTRESSED CONCRETE STRUCTURES (opens in a new tab)

  2. Modelling Reinforced and Prestressed Concrete Structures Subjected to Shear and Torsion

    In the design and analysis of reinforced and prestressed concrete structures, engineers are often faced with complex loading conditions that require the assessment of members subjected to shear and torsion. To develop a better understanding of the behaviour of such structures, twelve shell element …

    toronto-retro Repository record for Modelling Reinforced and Prestressed Concrete Structures Subjected to Shear and Torsion (opens in a new tab)

  3. Nondestructive testing of reinforced and prestressed concrete structures using acoustic waveguides

    … testing techniques for reinforced and prestressed concrete structures using acoustic waveguides. The first technique introduces a two-dimensional surface waveguide to enlarge the acoustic emission (AE) monitoring area of a reinforced concrete structure. A two-dimensional steel wire …

    wvu Repository record for Nondestructive testing of reinforced and prestressed concrete structures using acoustic waveguides (opens in a new tab)

  4. Optical fibre sensors for monitoring prestressed concrete structures in nuclear power plants

    … integrity, particularly of the reactors' prestressed concrete pressure vessels and containments is of prime concern. Currently, a lift-off inspection of a 1 % random sample of prestressing tendons is performed at 18 month to 5 year intervals to ensure adequate prestress is present in these …

    strathclyde Repository record for Optical fibre sensors for monitoring prestressed concrete structures in nuclear power plants (opens in a new tab)

  5. Optimum elastic design of prestressed concrete structures : with particular reference to statical indeterminacy

    <p>The thesis illustrates a general study for prestressed concrete structures. The main object is to develop an optimum solution for statically indeterminate prestressed concrete structures and provide an improved approach for the design engineer. A quadratic programming method is used to develop …

    soton Download PDF for Optimum elastic design of prestressed concrete structures : with particular reference to statical indeterminacy (opens in a new tab)

  6. Monitoring of prestressed concrete structures in a nuclear power plant with fibre Bragg grating systems

    Monitoring the prestress level of nuclear prestressed concrete containments and prestressed concrete pressure vessels is an important maintenance activity on a nuclear site. Adequate prestress level ensures the containment or vessel is able to withstand internal pressure and contain radioactive …

    strathclyde Repository record for Monitoring of prestressed concrete structures in a nuclear power plant with fibre Bragg grating systems (opens in a new tab)

  7. Time-Dependent Behavior of Noncomposite and Composite Prestressed Concrete Structures Under Field and Laboratory Conditions

    Made available in DSpace on 2014-12-10T22:21:51Z (GMT). No. of bitstreams: 1 7219887.pdf: 16377342 bytes, checksum: 6e6ca1f0882272319c45ac1385a0f2fc (MD5) Previous issue date: 1972

    uiuc Repository record for Time-Dependent Behavior of Noncomposite and Composite Prestressed Concrete Structures Under Field and Laboratory Conditions (opens in a new tab)

  8. Time-dependent analysis of continuous precast prestressed concrete beams.

    … of construction, analysis and design of precast prestressed concrete beams made continuous has been conducted from which various methods of achieving continuity between the precast units have been identified. A need to re-evaluate the analysis and design of such structures has been established …

    whiterose Download PDF for Time-dependent analysis of continuous precast prestressed concrete beams. (opens in a new tab)

  9. Understanding the Role of Materials in the Durability of Prestressed Concrete in Marine Environments

    The durability of prestressed concrete structures in marine environments is of increasing concern. Traditionally, emphasis of research on this topic has been placed on the chloride diffusivity and permeability of the cement paste in order to increase the service life of prestressed concrete …

    gatech Repository record for Understanding the Role of Materials in the Durability of Prestressed Concrete in Marine Environments (opens in a new tab)

  10. Estimation of beam prestress by deflection and strain measurements

    Laboratory test of reinforced and prestressed concrete structures have been used widely to explore the behavior of reinforced and prestressed concrete components and structures; Such tests are often time-consuming and costly. However, numerical models have been shown to compare favorably with …

    texas Repository record for Estimation of beam prestress by deflection and strain measurements (opens in a new tab)

  11. Development of Multifunctional Carbon Nanofiber Aggregate for Concrete Structural Health Monitoring

    Fiber research in concrete construction is an ongoing field and the use of carbon nanofibers (CNFs) will be examined in this study. Short-fiber composites are a class of strain sensor based on the concept of short electrically conducting fiber pull-out that accompanies slight and reversible crack …

    houston Repository record for Development of Multifunctional Carbon Nanofiber Aggregate for Concrete Structural Health Monitoring (opens in a new tab)

  12. Load Testing Deteriorated Spans of the Hampton Roads Bridge-Tunnel for Load Rating Recommendations

    … Hampton Roads Bridge-Tunnel is one of the oldest prestressed concrete structures in the United States. The 3.5 mile long twin structure includes the world's first underwater tunnel between two man-made islands. Throughout its 60 years in service, the harsh environment along the Virginia coast has …

    vt Repository record for Load Testing Deteriorated Spans of the Hampton Roads Bridge-Tunnel for Load Rating Recommendations (opens in a new tab)

  13. CFRP Tendons For The Repair Of Post-Tensioned, Ubonded Concrete Buildings

    The deterioration of prestressed concrete structures due to corrosion is a costly problem. This problem is accelerated in cold weather climates where de-icing salts are used. These salts accelerate the corrosion of the steel tendons greatly reducing the service life of the structures and leading to …

    queens Repository record for CFRP Tendons For The Repair Of Post-Tensioned, Ubonded Concrete Buildings (opens in a new tab)

  14. Investigation of Wire Ropes and Cables Using Ultrasound

    … tension. Some of the highly efficient cable structures include suspension bridges, prestressed concrete structures, and cable-stayed roofs. However, there is always a chance of damage in structures even if designed perfectly. To ensure the safety and serviceability of the structures, …

    tamu Repository record for Investigation of Wire Ropes and Cables Using Ultrasound (opens in a new tab)

  15. Evaluation of Post-tensioned Concrete Structures by Fiber Sensors: A study to develop sensor driven methods for evaluation of PRC elements, determine remaining prestressing force and assess key performance indicators.

    Prestressed concrete structures have numerous advantages over conventionally re inforced concrete, though the usage of post-tensioned structures has declined over the last decades. Structural health monitoring (SHM) have potential to change thistrend and by implementing this technique in civil …

    chalmers Repository record for Evaluation of Post-tensioned Concrete Structures by Fiber Sensors: A study to develop sensor driven methods for evaluation of PRC elements, determine remaining prestressing force and assess key performance indicators. (opens in a new tab)

  16. Effects of Accelerated Curing on the Time-Dependent Properties of Concrete

    The long-term creep and shrinkage behaviors of concrete can greatly affect the serviceability and constructability of prestressed concrete structures. To account for these effects, it is necessary to reliably predict the deformations of the concrete through time. These calculations are particularly …

    washington Repository record for Effects of Accelerated Curing on the Time-Dependent Properties of Concrete (opens in a new tab)

  17. Simplified Analytical Tools for Impact and Impulsive Loading Analysis of Reinforced Concrete Structures

    The analysis of reinforced and prestressed concrete elements under blast and impact loading is drawing the interest of many researchers due to increasing number of natural or human-made hazards that require attention. The analysis methods used are mainly based on either simplified single …

    toronto-retro Repository record for Simplified Analytical Tools for Impact and Impulsive Loading Analysis of Reinforced Concrete Structures (opens in a new tab)

Page 1 of 2