Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 20 for “"Primary Frequency Response"”.

  1. Methods to ensure the adequate primary frequency response of low inertia power systems

    … systems with lower inertia and reduced governor response. The expected continuation of this decline motivates research on economical methods to ensure primary frequency response (PFR) adequacy and prevent frequency-related emergency actions. This dissertation describes both demand-side and …

    uiuc Repository record for Methods to ensure the adequate primary frequency response of low inertia power systems (opens in a new tab)

  2. Control Paradigms For Distributed Energy Resources (Ders) To Engineer Inertial And Primary Frequency Response In Power Grids

    … a variety of disturbances that affect system frequency, and the problem is compounded with the increasing integration of intermittent renewable generation. Following a large-signal generation or load disturbance, system frequency is arrested, leveraging primary frequency control provided by …

    umn Repository record for Control Paradigms For Distributed Energy Resources (Ders) To Engineer Inertial And Primary Frequency Response In Power Grids (opens in a new tab)

  3. Measurement-Based Monitoring and Control in Power Systems with High Renewable Penetrations

    … study that keeps track of the inertial response and primary frequency response is conducted on the Eastern Interconnection (EI) for the past decade with field data. Whereas the inertia declined by at least 10%, the primary frequency response experienced an unexpected increase. The …

    utk-theses Repository record for Measurement-Based Monitoring and Control in Power Systems with High Renewable Penetrations (opens in a new tab)

  4. OPTIMAL OPERATION AND PLANNING OF MICROGRIDS CONSIDERING FREQUENCY STABILITY

    … of renewable plants weakens the grid’s frequency control capability. The frequency of a power system is an important indicator of any load-generation imbalance. If proper measures are not taken, the frequency-related events as a result of the contingencies might have devastating …

    sask Repository record for OPTIMAL OPERATION AND PLANNING OF MICROGRIDS CONSIDERING FREQUENCY STABILITY (opens in a new tab)

  5. Scalable modeling of future-grids under high penetration of distributed energy resources through multi-timescale T&D co-simulation

    … (PV), battery storage, electric vehicles, demand response with flexible loads, utility scale renewables, etc. These changes in the power grid are challenging the assumptions usually made for bulk power system analysis, especially that the distribution systems are passive consumers leading to …

    iastate Repository record for Scalable modeling of future-grids under high penetration of distributed energy resources through multi-timescale T&D co-simulation (opens in a new tab)

  6. Wind farm simulation modelling and control

    … farm controller design with the objectives of primary frequency response and power optimisation has also been investigated.

    strathclyde Repository record for Wind farm simulation modelling and control (opens in a new tab)

  7. An experimental and analytical method for assessing the integration of electric vehicles into the bulk power system

    … Texas, to analyze real-world behavior of EVs in response to control signals. The diverse group of participating vehicles provided rapid response between 1/6 and 1/2 second, suggesting a strong capacity for providing grid reliability services. Successful real-world tests of primary frequency …

    texas Repository record for An experimental and analytical method for assessing the integration of electric vehicles into the bulk power system (opens in a new tab)

  8. Impact of high renewable energy penetration on ERCOT’s frequency response reliability

    … can affect grid reliability during disturbances; frequency response time is affected by the generation and storage technologies active at the time. As less grid power comes from generators with synchronized rotating machines (e.g., coal, natural gas, nuclear), possibly due to increasing use of …

    texas Repository record for Impact of high renewable energy penetration on ERCOT’s frequency response reliability (opens in a new tab)

  9. A Comprehensive Frequency Control Framework for High Penetration of Wind

    … will have significant impact on power system frequency response and brings new challenge to traditional power system frequency framework. With converter interface, the wind unit's rotor inertia is effectively decoupled from the system, causing a reduction in inertial response. Moreover, the …

    utk-theses Repository record for A Comprehensive Frequency Control Framework for High Penetration of Wind (opens in a new tab)

  10. Dynamic Modeling and Renewable Integration Studies on the U.S. Power Grids

    … U.S. EI system in year 2030. The second project, Frequency Response Assessment and Improvement of Three Major North American Interconnections due to High Penetrations of Photovoltaic Generation, concentrates on the influence of high solar penetration on primary frequency response.</p> <p>This …

    utk-theses Repository record for Dynamic Modeling and Renewable Integration Studies on the U.S. Power Grids (opens in a new tab)

  11. Efficient Control Approaches for Guaranteed Frequency Performance in Power Systems

    … in power systems and degrading the grid frequency response. Synthetic inertia emulation and guaranteed primary frequency response is a challenging task. Still, there is high potential for application of highly controllable converter-interfaced devices to help performance. Renewable energy …

    utk-theses Repository record for Efficient Control Approaches for Guaranteed Frequency Performance in Power Systems (opens in a new tab)

  12. Wide-Area Synchrophasor Measurement Applications and Power System Dynamic Modeling

    … situation awareness and reliability improvement. Frequency Monitoring Network (FNET), as an academia-run synchrophasor measurement system, utilizes a large number of Internet-connected low-cost Frequency Disturbance Recorders (FDRs) installed at the distribution level to measure power system …

    utk-theses Repository record for Wide-Area Synchrophasor Measurement Applications and Power System Dynamic Modeling (opens in a new tab)

  13. Development and validation of improved electromagnetic transient simulation models for solar photovoltaic energy systems

    … is critical for maintaining system stability. Frequency measurement accuracy becomes especially important when PV plants participate in power-frequency control, as errors during transients can lead to maloperation. To address these challenges, two key enhancements are proposed to the Double …

    manitoba Repository record for Development and validation of improved electromagnetic transient simulation models for solar photovoltaic energy systems (opens in a new tab)

  14. Improving Grid Frequency Response using Wind Generation Resources

    … Electric Reliability Corporation (NERC) in response to the increasing mix of Wind Generation Resources and growing concerns of system stability and reliability in US interconnections (especially ERCOT region). This concern is due to lack of inertia, primary and secondary frequency response …

    ttu Repository record for Improving Grid Frequency Response using Wind Generation Resources (opens in a new tab)

  15. Provision of power system frequency response in the context of high wind penetration

    … that wind plant can contribute to power system frequency control and stability. These are important in the context of increasing wind penetration level into power systems and because variable speed wind turbines that are now the dominant technology do not directly contribute to system inertia, …

    strathclyde Repository record for Provision of power system frequency response in the context of high wind penetration (opens in a new tab)

  16. Valuing of inertia and fast-acting storage devices in interconnected power grids

    … result in: 1) less inertia and maybe worse primary frequency responses (from transient stability perspective of view); 2) stricter ramping requirement (from system operation perspective of view). Fast-acting storage devices can provide both energy and ancillary services through some specific …

    uiuc Repository record for Valuing of inertia and fast-acting storage devices in interconnected power grids (opens in a new tab)

  17. Non-convex myopic electricity markets : the AC transmission network and interdependent reserve types

    … simultaneously with a new definition of the primary frequency responsive reserve types considered in the market. One of these reserve types intends to accommodate standard droop control. Another of these reserve types is newly introduced and intends to facilitate participation of fast-acting …

    texas Repository record for Non-convex myopic electricity markets : the AC transmission network and interdependent reserve types (opens in a new tab)

  18. Droplet behavior on superhydrophobic surfaces: Interfaces, interactions, and transport

    The primary objective of the present work is to study droplet dynamics on smooth hydrophobic and textured superhydrophobic surfaces, and to understand the dependence of interfacial interaction mechanisms on surface morphology. ^ A detailed understanding of the dynamics of droplet response to an …

    purdue-thes Repository record for Droplet behavior on superhydrophobic surfaces: Interfaces, interactions, and transport (opens in a new tab)

  19. Analysis of frequency control and grid storage effectiveness for a west African interconnected transmission system

    … System (WAPPITS) has faced challenges with frequency control due to limited primary frequency control reserves (PFR). Battery Energy Storage Systems (BESS) have been identified as a possible solution to address frequency control challenges and to support growing levels of variable renewable …

    colostate Repository record for Analysis of frequency control and grid storage effectiveness for a west African interconnected transmission system (opens in a new tab)

  20. Frequency and Voltage Control of a Grid of Microgrids

    … interconnected ac and dc microgrids, and provide frequency support, voltage regulation, and virtual inertia for individual microgrids and the host grid as required, to improve both frequency and voltage dynamics for the overall system. Thus, a hierarchical distributed control technique is …

    waterloo Repository record for Frequency and Voltage Control of a Grid of Microgrids (opens in a new tab)