  1. Protection of Multi-Terminal HVDC Grids

    This thesis introduces four novel protection schemes for multi-terminal HVDC grids: primary protection, fault location identification, and breaker/relay failure backup protection schemes. The proposed single-ended primary protection scheme employs Hilbert-Huang Transform (HHT) to extract two …

    waterloo Repository record for Protection of Multi-Terminal HVDC Grids (opens in a new tab)

  2. Hidden Failures in Protection Systems and its Impact on Power System Wide-area Disturbances

    This document explores Hidden Failures in protection systems, which have been identified as key contributors in the degradation of Power System wide-area disturbances. The Hidden Failure Modes in which the protection systems may fail to operate correctly and their consequences are identified in a …

    vt Repository record for Hidden Failures in Protection Systems and its Impact on Power System Wide-area Disturbances (opens in a new tab)

  3. Proteção de sobrecorrente direcional utilizando transformada wavelet

    Traditionally, the primary protection used in low voltage power systems, as distribution systems, is the overcurrent protection due to its simplicity and low cost. However, in these recent years, the number of distributed generation connected to the system has been growing, which changes the …

    brazil-ufrn Repository record for Proteção de sobrecorrente direcional utilizando transformada wavelet (opens in a new tab)

  4. DEVELOPMENT OF AN IMPROVED COMBINED NUMERICAL DISTANCE AND OVERCURRENT RELAY

    Distance protection schemes are widely used for the protection of high voltage transmission lines. This form of protection is of the high speed and can provide both primary and back-up facilities in a single scheme. To meet the rapid development of the power systems and the large amount of the …

    nus Repository record for DEVELOPMENT OF AN IMPROVED COMBINED NUMERICAL DISTANCE AND OVERCURRENT RELAY (opens in a new tab) Download file for DEVELOPMENT OF AN IMPROVED COMBINED NUMERICAL DISTANCE AND OVERCURRENT RELAY (opens in a new tab)

  5. Teisės į kūno neliečiamumą ir vientisumą gynimo lyginamieji aspektai Lietuvos Respublikoje ir Jungtinėje Karalystėje /

    … the analysis of the comparative aspects of the protection of the person’s right to the bodily inviolability and integrity in different law systems – the Republic of Lithuania and the United Kingdom. Moreover, the aim of the present research is to analyse when and how the person’s right to the …

    vilnius Repository record for Teisės į kūno neliečiamumą ir vientisumą gynimo lyginamieji aspektai Lietuvos Respublikoje ir Jungtinėje Karalystėje / (opens in a new tab)

  6. An economic analysis and operations research of wildfire management

    … as positively correlated. Third, suppression and primary protection are incorrectly modeled as negatively correlated. These errors are shown to be perpetuated by the contemporary C+NVC model, and to have serious implications for the model's capacity to correctly identify the most efficient level …

    colostate Repository record for An economic analysis and operations research of wildfire management (opens in a new tab)

  7. Protection of traffic in IP-over-WDM networks using loop-free alternates

    … Fast Reroute (MPLS FRR) can also provide protection, but it involves installing and maintaining an additional network layer on top of IP. A simple and commercially available mechanism to protect high priority traffic in the IP layer is Loop-free Alternates (LFA). However, a network …

    hawaii Repository record for Protection of traffic in IP-over-WDM networks using loop-free alternates (opens in a new tab)

  8. Otimização da parametrização de relés em sistemas radiais de distribuição de energia elétrica com utilização do algoritmo genético

    … by the National Electric Energy Agency. The protection of electrical systems plays a fundamental role in the maintenance of this system and in the control of its indicators. Distribution systems have several physical and technical characteristics, such as the operating time of the devices, …

    brazil-ufrn Repository record for Otimização da parametrização de relés em sistemas radiais de distribuição de energia elétrica com utilização do algoritmo genético (opens in a new tab)

  9. Protection System Design and Engineering for Safe and Reliable Transmission System Operation

    … response. The work also included, in large part, protection and control engineering across a wide range of equipment (e.g., transmission lines, buses, transformers, reactors, capacitor banks, and generators)), together with the study of key power-system phenomena such as ferroresonance, …

    utk-theses Repository record for Protection System Design and Engineering for Safe and Reliable Transmission System Operation (opens in a new tab)

  10. CHARACTERIZATION OF NOVEL CYP26B1-INHIBITOR, DX314, FOR THE TREATMENT OF KERATINIZATION DISORDERS

    … provided by the epidermis, functions as our primary protection from the harsh environment. It protects us from dangerous pathogens, allergens, ultraviolet radiation, and mechanical injury, as well as playing a major role in fluid and thermal regulation. Disruption of skin functions can lead …

    montana-tech Repository record for CHARACTERIZATION OF NOVEL CYP26B1-INHIBITOR, DX314, FOR THE TREATMENT OF KERATINIZATION DISORDERS (opens in a new tab)

  11. CHARACTERIZATION OF NOVEL CYP26B1-INHIBITOR, DX314, FOR THE TREATMENT OF KERATINIZATION DISORDERS

    … provided by the epidermis, functions as our primary protection from the harsh environment. It protects us from dangerous pathogens, allergens, ultraviolet radiation, and mechanical injury, as well as playing a major role in fluid and thermal regulation. Disruption of skin functions can lead …

    montana Repository record for CHARACTERIZATION OF NOVEL CYP26B1-INHIBITOR, DX314, FOR THE TREATMENT OF KERATINIZATION DISORDERS (opens in a new tab)

  12. Optimizing the planning of remote construction sites to minimize the consequences of explosive attacks

    … of remote construction sites utilize three primary protection measures that are designed to: (i) increase the standoff distances between site facilities and the potential location of an explosive device; (ii) construct perimeter walls to mitigate blast loads on facilities; and (iii) harden …

    uiuc Repository record for Optimizing the planning of remote construction sites to minimize the consequences of explosive attacks (opens in a new tab)

  13. Βελτιστοποίηση ρυθμίσεων στοιχείων υπερέντασης σε προσαρμοστικά ή μη συστήματα προστασίας σύγχρονων δικτύων διανομής και συστημάτων μεταφοράς

    … novel methods, regarding the concept of adaptive protection systems in modern distribution networks and the automated calculation of optimal relay setting values for the overcurrent elements of adaptive or non-adaptive protection systems. The latter method is appropriate for distribution networks, …

    greece Repository record for Βελτιστοποίηση ρυθμίσεων στοιχείων υπερέντασης σε προσαρμοστικά ή μη συστήματα προστασίας σύγχρονων δικτύων διανομής και συστημάτων μεταφοράς (opens in a new tab)

  14. Resilient power and propulsion system design for eVTOL aircraft

    … failure interdependencies and EPS protection methodology to ensure a reliable EPS Therefore, the main research contributions of this thesis include the development of a novel design methodology to capture a certification-compliant EPS architecture for an eVTOL at the preliminary …

    strathclyde Repository record for Resilient power and propulsion system design for eVTOL aircraft (opens in a new tab)

  15. Protection of Microgrids: A Scalable and Topology Agnostic Scheme With Self-Healing Dynamic Reconfiguration

    … against disturbances and faults are the primary focus. For the proper functioning of these microgrids, there is a need for grid-forming inverters that can enable acceptable performance and coexist with conventional grid-following inverters that supply only positive-sequence currents. In …

    clemson Repository record for Protection of Microgrids: A Scalable and Topology Agnostic Scheme With Self-Healing Dynamic Reconfiguration (opens in a new tab)

  16. A Modular Multilevel Converter that Integrates Artificial Intelligence for Fault Locating and Protection

    … the inability of the converter to offer DC fault protection, since conventional control schemes always struggle to achieve converter energy balance and DC Fault Ride Through (DC-FRT) capability due to the unbalanced system parameters. Reviewing this research gap, a novel control structure has been …

    auckland-tech Repository record for A Modular Multilevel Converter that Integrates Artificial Intelligence for Fault Locating and Protection (opens in a new tab)

  17. Protection of multi-terminal direct current transmission systems

    … is to develop a complete approach towards the protection of Multi-Terminal Direct Current (MTDC) systems. Firstly, to understand the propagation of faults on the DC transmission network, an in-depth analysis of fault characteristics has been performed. This analysis enables optimal sizing of DC …

    gatech Repository record for Protection of multi-terminal direct current transmission systems (opens in a new tab)

  18. Studium možností ochrany zdiva v záplavových oblastech

    Práce se věnuje možnostem primární a sekundární ochrany zdiva v oblasti spodní stavby v záplavových oblastech. Náplní práce je provedení literární rešerše v oblasti zatížení zdiva při povodních a řešení konstrukce tak aby nedocházelo k jeho degradaci a destrukci. Práce se dále věnuje návrhu …

    brno-tech Repository record for Studium možností ochrany zdiva v záplavových oblastech (opens in a new tab)