Results 1 to 17 of 17 for “"Prior Image"”
-
On-board Image Augmentation Using Prior Image and Deep Learning for Image-guided Radiation Therapy
… Tomography (CBCT) has been widely used in image-guided radiation therapy for target localization. 3D CBCT has been developed for localizing static targets, while 4D CBCT has been developed for localizing moving targets. Although CBCT has been used as the gold standard in current clinical …
-
Penalized maximum likelihood method for reducing limited-angle artifacts in image reconstructions for a dual-panel high-spatial-resolution pet system
… plane leads to distortions in reconstructed images. In this work, we study a penalized maximum likelihood (PML) image reconstruction method for reducing the limited-angle artifacts arising from the insufficient angular sampling. A prior image is pre-reconstructed from a whole-body …
-
Compressed Sensing Based Reconstruction Algorithm for X-ray Dose Reduction in Synchrotron Source Micro Computed Tomography
… angular projections to reconstruct tomographic images with high resolution for detailed and accurate diagnosis. However, this exposes the specimen to a large amount of x-ray radiation. Furthermore, this increases scan time and, consequently, the likelihood of involuntary specimen movements. One …
-
Cone-Beam Computed Tomography For Neuro-Angiographic Imaging
… that require timely diagnosis. However, image quality in CBCT scanners are potentially limited by slow rotation speed and are therefore challenged in the context of hemodynamic neurovascular imaging, as in CT Angiography (CTA) and CT Perfusion (CTP). This thesis details the advancement of …
-
Development of Handheld Optical Coherence Tomography Device for Imaging Oral Vasculature in Soft Tissues
… imaging technique that produces high-resolutionimages at shallow tissue depths of 1-2 mm. Optical Coherence Tomography Angiography (OCTA), creates 3-D angiograms to distinguish between structural tissue beds and blood flow, making OCT ideal for imaging dental vasculature. The Biophotonics and …
-
Impressions: Understanding Visual Semiotics and Aesthetic Impact
… through which to investigate the semiotics of images, and how specific visual features and design choices can elicit specific emotions, thoughts and beliefs. We posit that the impactfulness of an image extends beyond formal definitions of aesthetics, to its success as a communicative act, where …
-
Compressed Sensing Based Image Restoration Algorithm with Prior Information: Software and Hardware Implementations for Image Guided Therapy
… platform for developing a total-variation based image restoration algorithm by applying prior image information and free-form deformation fields for image guided therapy. The core algorithm we developed solves the image restoration problem for handling missing structures in one image set with …
-
Flexible Radial Data Acquisition and Image Reconstruction Strategies for Breast Magnetic Resonance Imaging
… from benign lesions can be improved by acquiring images of high spatial resolution for visualizing morphological features of tumours and those of high temporal resolution for characterizing contrast-kinetic curves. However, simultaneously achieving high spatial and temporal resolution is limited …
-
FORMAL BAYESIAN APPROACHES TO THE SENSE AND GRAPPA PARALLEL FMRI RECONSTRUCTION TECHNIQUES ALONG WITH THEIR COMBINATION
… is dependent on how quickly volume brain images are acquired. The sampling time for an array of spatial frequencies to reconstruct an image is the limiting factor in the fMRI process. Parallel imaging techniques Sensitivity Encoding (SENSE), which operates in the image space domain, and …
-
På Raets Brodd: Breaking the hermeneutic circle of tourism in peripheral landscapes
… are increasingly reduced to consumable images – a condition reinforced by what Urry and Larsen (2011) describe as the hermeneutic circle of tourism, where visitors arrive with pre-formed images derived from media and seek their confirmation in the landscape. Existing tourism …
-
Statistical Shape Analysis to Quantify Lung Structure-Function Relationships over the Adult Lifespan
… Thirdly, the model was used to derive a priori knowledge to robustly estimate the locations of pulmonary fissures on Computed Tomography (CT) imaging, aiding the current lobar segmentation algorithms. Lastly, a novel technique was developed to predict the lung shape of a new healthy human …
-
Joint PET-MR Image Reconstruction with Machine Learning
… It allows for more detailed and informative images than using separate modalities, exploiting both PET functional information and MRI high-resolution images of the body's anatomy. Shortcomings from each modality are compensated by the other. Joint PET-MR imaging is mainly applied for …
-
Model-Based Iterative Reconstruction in Cone-Beam Computed Tomography: Advanced Models of Imaging Physics and Prior Information
… that provides three-dimensional (3D) volumetric images with sub-millimeter spatial resolution and soft-tissue visibility from a single gantry rotation. CBCT tends to have small footprint, mechanical simplicity, open geometry, and low cost compared to conventional diagnostic CT. Because of these …
-
Entwicklung eines neuen vorwissensbasierten Bildrekonstruktionsalgorithmus für die Cone-Beam-CT Bildgebung in der Strahlentherapie
… vorhandene Vorwissensbilder verwendet, ist der Prior-Image- Constrained-Compressed-Sensing-Rekonstruktionsalgorithmus (PICCS). Die Rekonstruktionsergebnisse des PICCS-Verfahrens übertreffen die Ergebnisse des auf den konventionellen Feldkamp-Davis-Kress-Algorithmus (FDK) basierenden Verfahrens, …
-
Robust Coil Combination for bSSFP MRI and the Ordering Problem for Compressed Sensing
… rate and its application is natural in MR where images are often sparse under common linear transforms. An extension of this framework is the ordering problem for CS, first introduced in 2008. Although the assumption is made in CS that images are sparse in some specified transform domain, it …
-
Optimization of Image Guided Radiation Therapy for Lung Cancer Using Limited-angle Projections
… limited-angle on-board x-ray projections for image guidance. The limited-angle acquisition enables scan time and imaging dose reduction and improves the mechanical clearance of imaging.</p><p>First of all, the dissertation developed a phase-matched digital tomosynthesis (DTS) technique using …
-
Volumetric Cine Imaging for On-board Target Localization in Radiation Therapy
… moving targets for on-board localization cannot image full volumetric information in real-time. The purposes of this dissertation research are to do the following. (1) Develop a real-time quasi-cine CBCT reconstruction method for on-board CBCT-guided target verification; (2) Develop a volumetric …