The Design and Performance of a Fiber Optic Pressure Transducer
… diameters, thicknesses, source-detector distances, and source-detector arrangements are explored in static and dynamic testing. A 0.3125 inch diameter, 2 mil thick, H19 aluminum diaphragm operating at a probe distance of one inch was found to be the optimum configuration for this system …
-
Ανάπτυξη τομογραφικών γεωφυσικών τεχνικών για τη μελέτη γεωτεχνικών και περιβαλλοντικών προβλημάτων
… row is placed on the surface and another one is probed into the earth. This array is labeled as ‘surface-to-tunnel’ which has two rows of electrodes running parallel while the ‘interior’ row is placed inside a tunnel.This new array can ‘see’ the area in between the electrodes better in comparison …
-
Dynamics of spatial attention during motion tracking: Characterization and modeling as a function of motion predictability
… moving at varying predictability levels. A probe was flashed ahead or behind target motion (2° or 6°), and manual response times (MRT) to probes were collected to indicate attention level. To investigate the temporal dynamics of attentional bias, a second tracking task was performed where …
-
DIAGNOSTICS AND REAL-TIME MONITORING OF PULSED LASER ABLATION
… electric field is measured by a tiny metal probe. Signal analyses show that it is resulted from the contribution of an electric dipole formed at the early stage of laser ablation. Formation of the electric field is briefly modeled. Signal variation with laser fluence, probe distance, …
-
Toward Polymer Coating with Easy Ice Release
… of an ice cylinder from a polymer coating with a probe and the determination of peak removal force (Ps). To validate the test method, the strength of ice adhesion was determined for a prototypical glassy polymer, poly(methyl methacrylate). The distance of the probe from the PMMA surface has been …
-
Experimental and Numerical Investigations for an Advanced Modeling of Two-Phase Flow and Mass Transfer on Column Trays
… profiler comprising 776 dual-tip conductivity probes for simultaneous conductivity measurements was introduced for hydrodynamic characterization. The spatial resolution of the profiler based on the inter-probe distance was 21 mm × 24 mm, whereas the temporal resolution was 5000 Hz. The design …
-
Měření fyzikálních veličin na rotujících částech
Práce je věnována bezkontaktnímu měření malých vzdáleností na rotujíích částech elektrickcých strojů. Zvláště je pak věnována pozornost sledování tvarových úchylek komutátoru a kroužku elektrických strojů. Pro sledování malých vzdáleností jsou použity indukční snímací sondy vyvinutých na ÚVEE FEKT …