Showing 1 to 11 of 11 for “"Process bus"”.
-
Dynamic phasor estimation in electrical power systems based on IEC61850 Process-Bus.
… of Ethernet network communication. It uses a Process-Bus to link the equipment at switchyard and devices of protection and control at bay level. To enhance the phasor estimation and move from static to dynamic estimation, the high sampling rate of raw data provided by the Merging Unit as …
-
Performance Analysis of Sampled Values-Based Protection in IEC 61850 Process Bus Networks
As the IEC 61850 digital substation standard becomes progressively adopted by utilities throughout the world, entirely computerized methods will completely replace traditional strategies for monitoring the power system. Although newer techniques offer enhanced efficiency and controllability, their …
-
Automatizace rozvodny VN s využitím řídicího systému COM600 a standardu IEC61850
… IEC 61850-9-2 LE je spíše známá jako komunikace Process bus. V práci jsou popsány rozšiřující nástroje použité v řídicím systému COM 600 a jejich detailní konfigurace. Dále se práce zabývá konfigurací standardu IEC 61850- 9-2 LE v ochranných terminálech rodiny Relion a její následné implementaci …
-
Development of Protection Scheme for Non-Conventional Instrument Transformer (NCITs) Based on IEC 61850-9-2
… Values transmission over an Ethernet link called Process Bus. This thesis is mainly based on the development of the non Conventional Instrument Transformers (NCIT), analogue to digital data converter and power system protection.
-
A Security Evaluation of a Platform Intended for Critical Infrastructure - A Case Study for Sinusoidal Systems
… of traditional physical power meters by processing data directly from the IEC61850 process bus. This allows multiple virtual meters to operate efficiently on a single hardware unit. While the operational feasibility and precision of the DMP have been carefully tested, its cybersecurity …
-
A methodology for performance and compatibility evaluation of an all-digital substation protection system
… relays through a digital communication link (process bus). Due to their design, conventional instrument transformers introduce distortions to the current and voltage signal replicas. These distortions may cause protective relays to misoperate. On the other hand, non-conventional instrument …
-
Algorithms for the synchrophasor measurement in steady-state and dynamic conditions
… particular, a measurement architecture based on process bus and sampled values synchronized with IEEE 1588-2008 is proposed, so that voltage and current signals are acquired by a Merging Unit device, while the PMU signal processing is performed on a IED (Intelligent Electronic Device), in …
-
A digital relaying algorithm for integrated power system protection and control
… requirements of a digital relaying algorithm for processing samples that are sent across Ethernet-based communication channels. The work shows the shortcomings and unstable performance of widely used protective algorithms in accommodating data samples that are out of step from their proper …
-
Design and Development of Protection, Control and SCADA of Model Zone Substation Laboratory Based on The IEC61850 Communication Standard
… lines, two distribution transformers, bus couplers and feeders and their protection, control, measuring ang monitoring systems. For this SAS arrangements there are eight protection and control panels have been included to match the real-world scenario. Therefore, protection and control …
-
Aplikace senzorů a digitalizace podle IEC 61850 v sítích a rozvodnách vysokého napětí
Vzduchem izolované vysokonapěťové rozváděče jsou nedílnou součástí energetického distribučního řetězce a to jak v průmyslovém, tak ve veřejném sektoru. Hlavní funkcí rozváděče je ochrana pracovního personálu, rozpojování/odpojování a spínání, izolování, měření proudů a napětí, chránění a ovládání …
-
Analytical Hierarchy Process Evaluation of the Proposed Slim Modular Flexible Electric Bus Rapid Transit System
… proposed with the possible implementation of Bus Rapid Transit (BRT) system. Although BRT has gained popularity for its operational flexibility and efficiency, efforts have been put into developing a new concept vehicle that is better functioning and more cost-effective. Slim Modular Flexible …