  1. Multiwire proportional counters

    … first, to develop a multilayered multiwire proportional chamber which would be useful as a position-sensitive detector in tracking the path of a beam of elementary particles and identifying the particles by their energies; and second, to measure the operating characteristics of such a …

    ubc Repository record for Multiwire proportional counters (opens in a new tab) Download PDF for Multiwire proportional counters (opens in a new tab)

  2. A study of parallel plate proportional counters

    … the construction and study of a parallel plate proportional counter (PPPC). The PPPC was found to be essentially 100% efficient in the detection of 3 MeV protons. Gas gains near 104 were obtained in the pressure range between 177-355 torr. The rise time of the PPPC pulse for a plate separation …

    rice Repository record for A study of parallel plate proportional counters (opens in a new tab)

  3. Studies of orbital electron capture using proportional counters

    … but it is pointed out that the development of proportional counter techniques for studying low energy radiations has made better measurements possible. These techniques are discussed in the following chapter, with particular emphasis on the use of gaseous sources. The material of this …

    glasgow Repository record for Studies of orbital electron capture using proportional counters (opens in a new tab) Download PDF for Studies of orbital electron capture using proportional counters (opens in a new tab)

  4. Position-sensitive proportional counters using resistance-capacitance position encoding

    … photons, neutrons, or charged particles in proportional counters by using the distributed RC line characteristics of these counters. The signal processing is described and guidelines for the design and operation of these position sensitive proportional counters (PSPCs) are given.</p><p>Using …

    ut-knoxville Repository record for Position-sensitive proportional counters using resistance-capacitance position encoding (opens in a new tab)

  5. The study of beta-gamma decay schemes using proportional counters

    After a short introductory chapter, a critical summary of previous work is contained in chapter 2, and the need for coincidence methods in dealing with more complex decay schemes is discussed. The contents of these chapters are drawn mainly from original papers although use has been made of …

    glasgow Download PDF for The study of beta-gamma decay schemes using proportional counters (opens in a new tab)

  6. Characterization of mixed linear energy transfer environments utilizing tissue-equivalent proportional counters

    … transfer (LET) environment. A tissue equivalent proportional counter (TEPC) was used to produce dose-equivalent measurements and quantify neutron exposures. Three neutron sources were used to simulate high energy, mixed LET environments: californium-252, a plutonium-beryllium source, and a …

    colostate Repository record for Characterization of mixed linear energy transfer environments utilizing tissue-equivalent proportional counters (opens in a new tab)

  7. Monte Carlo Simulations of Grid Walled Proportional Counters with Different Site Sizes for HZE Radiation

    Tissue-equivalent proportional counters are frequently used to measure dose and dose equivalent in cosmic radiation fields that include high-Z, high-energy (HZE) particles. The fact that particles with different stopping powers can produce the same energy deposition in the same detector means that …

    tamu Repository record for Monte Carlo Simulations of Grid Walled Proportional Counters with Different Site Sizes for HZE Radiation (opens in a new tab)

  8. Monte Carlo simulations of solid walled proportional counters with different site size for HZE radiation

    … to astronauts. Low pressure, tissue equivalent proportional counters (TEPC) are routinely used to evaluate radiation exposures in space. A multiple detector system composed of three TEPC of different sizes was simulated using the Monte-Carlo software toolkit GEANT4. The ability of the set of …

    tamu Repository record for Monte Carlo simulations of solid walled proportional counters with different site size for HZE radiation (opens in a new tab)

  9. Design and characterization of next-generation tissue equivalent proportional counters for use in low energy neutron fields

    Tissue Equivalent Proportional Counters (TEPCs) are devices that can measure the radiation dose levels for the mixed neutron and gamma ray fields that are encountered in nuclear facilities. TEPC designs typically consist of a low density gas sensitive volume surrounded by a solid wall, each of …

    uoit Repository record for Design and characterization of next-generation tissue equivalent proportional counters for use in low energy neutron fields (opens in a new tab)

  10. Investigation and use of dual (twin) low pressure proportional counters for active neutron-gamma mixed field dosimetry

    … dose-rate measurements. Tissue equivalent proportional counters (TEPCs) have been used, but their accuracy is limited. In this study, a custom-built Cylindrical Graphite Proportional Counter (Cy-GPC) along with a twin Cylindrical TEPC (Cy-TEPC) has been extensively investigated for n-γ …

    uoit Repository record for Investigation and use of dual (twin) low pressure proportional counters for active neutron-gamma mixed field dosimetry (opens in a new tab)

  11. A measurement of the diffraction scattering of pions and protons from complex nuclei using multiwire proportional counters

    … with the development and testing of mu1tiwire proportional counters. The second part involves the use of a proportional counter system in an experiment to study the diffraction scattering of protons and positive pions from various complex nuclei. A good precision experiment is made considerably …

    uiuc Repository record for A measurement of the diffraction scattering of pions and protons from complex nuclei using multiwire proportional counters (opens in a new tab)

  12. Cylindrical Detector and Preamplifier Design for Detecting Neutrons

    Tissue equivalent proportional counters are frequently used to measure dose and dose equivalent in mixed radiation fields that include neutrons; however, detectors simulating sites 1?m in diameter underestimate the quality factor, Q, for low energy neutrons because the recoil protons do not cross …

    tamu Repository record for Cylindrical Detector and Preamplifier Design for Detecting Neutrons (opens in a new tab)

  13. HALO-1kT prototype He-3 counters: background studies

    … of backgrounds is the planned 4.3 km of helium-3 proportional counters. My research tested the prototype proportional counters to ensure their backgrounds are low enough to avoid regular false positives. The first way of testing them was to take the 4 counters underground at SNOLAB to collect 3-4 …

    laurentian Repository record for HALO-1kT prototype He-3 counters: background studies (opens in a new tab)

  14. An Analysis of the 3-He Proportional Counter Data from the Sudbury Neutrino Observatory Using Pulse Shape Discrimination

    … analysis of the data from 3-He-filled proportional counters from the third phase of the Sudbury Neutrino Observatory (SNO) data. These counters were deployed in SNO's heavy water to independently detect neutrons produced by the neutral current interaction of 8-B solar neutrinos with …

    queens Repository record for An Analysis of the 3-He Proportional Counter Data from the Sudbury Neutrino Observatory Using Pulse Shape Discrimination (opens in a new tab)

  15. An investigation of some techniques for the localisation of ionizing radiation

    … the development and study of position sensitive proportional counters and was initiated by Dr. R.W.P, Drever. The first chapter of this thesis is a discussion of the type of experimental problems which require the spatial distribution of ionizing radiation to be investigated and of the different …

    glasgow Download PDF for An investigation of some techniques for the localisation of ionizing radiation (opens in a new tab)

  16. Design, construction and implementation of spherical tissue equivalent proportional counter

    Tissue equivalent proportional counters (TEPC) are used for medical and space activities whenever a combination of high and low LET (lineal energy transfer) radiations are present. With the frequency and duration of space activities increasing, exposure to fast heavy ions from galactic cosmic …

    tamu Repository record for Design, construction and implementation of spherical tissue equivalent proportional counter (opens in a new tab)