Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 59 for “"Prosthesis control"”
-
Image Sensor Classification System for Prosthesis Control
… an image sensor classification system into the control scheme for prosthetic limbs. The goal is to minimize the mental strain experienced by brain-computer interface (BCI) users when performing routine tasks. In particular, the focus is to investigate the capabilities of image classification as …
-
Recognition of objects to grasp and Neuro-Prosthesis control
L'objectif de la recherche doctorale est de fournir une assistance aux amputés des membres supérieurs portant des prothèses robotisés. Le contrôle myoélectrique classique des neuro-prothèses est limité en cas d'amputation sévère. L'approche de la vision par ordinateur et les informations sur le …
-
Gaze2Grasp: Vision-based system for pre-grasp prosthesis control
… often forced to deal with the limitations of the prosthesis by employing compensation strategies, like "overhanging toe" in stair descent and shoulder compensations in grasping tasks. My research aims to ease the burden placed on prosthetic limb users by using the learning capabilities from …
-
Non–invasive electromyography–based sensing for proportional prosthesis control
… human motivation suggests self-actualisation and control of one's own situation being most needed. The psychological implications of any disability are described in Maslow's theory of human motivation, based on human hierarchy of needs. "Self-actualisation" is placed on top of all needs. By having …
-
Prosthesis control using a nearest neighbor electromyographic pattern classifier
A prosthesis control strategy using a nearest neighbor electromyographic pattern classifier was investigated with both a real time microprocessor-based controller and offline computational facilities. Four active electrodes for myoelectric signal amplitude detection were interfaced with a …
-
Investigations on upper limb prosthesis control with an active elbow
Les progrès de la mécatronique ont permis d’améliorer les prothèses du membre supérieur en augmentant le catalogue des mouvements prothétiques. Cependant, un fossé se creuse entre les capacités technologiques de la prothèse et leur méthode de contrôle. La commande myoélectrique, qui est la méthode …
-
Surface myoelectric signal analysis and enhancement for improved prosthesis control
… are presented in the field of myoelectric control. Specifically, algorithms for activity detection, noise identification and noise reduction are introduced, evaluated and discussed. The ultimate aim has been to develop algorithms to improve the performance of prosthetic control systems that …
-
REGENERATIVE BIONICS: INCORPORATING REINNERVATED MUSCLE INTO BIONIC SYSTEMS FOR PROSTHESIS CONTROL
… muscle as a component in bionic systems for prosthesis control. Its popularity is due mainly to the pain relief benefits of muscle reinnervation, but it also offers the bio-amplification of nerve signals if the reinnervated muscle can be recorded from long-term. There are many varieties of …
-
Bayesian nonparametric methods for dynamics identification and segmentation for powered prosthesis control
… in particular: their user. This is an adaptive control problem which speaks of the need for powered prostheses to have anthropomorphic adaptive capabilities. However, it is inconceivable that all possible movements, dynamics and tasks can be preprogrammed into such a system. Prostheses, like …
-
Incorporating User Feedback in Supervised Machine Learning for Long-term Prosthesis Control
… devices are available on the market, but the control strategies offered with these prostheses fall short of both their true capabilities and the users’ expectations. Contemporary research in control strategies is focused around pattern recognition which is a machine learning based method, …
-
Improving hand prosthesis control with advanced single-finger proportional decoding and robotic shared control
… allow users to recover lost functionality by controlling a robotic device with their remaining muscle activity. Commercial devices usually use a two-recording-channel system placed on specific muscles to control a single degree of freedom, i.e. one sEMG channel for flexion and one for …
-
Development of a Conformal Textile Electrode Liner for the Purpose of Myoelectric Prosthesis Control
… and electrode shift, resulting in weaker control or loss of control of the prosthesis. The work in this thesis focuses on the development of an alternative electrode interface that we will refer to as the ``MyoLiner". The MyoLiner comprises textile electrodes embedded directly into a …
-
Transfemoral Prosthesis Control for Inclined Walking Using Impedance Control and Bezier Polynomial Based Optimization
A powered transfemoral prosthesis is an assistive device for patients with above knee amputation. For these patients, walking on various sloped surfaces is one of the most challenging tasks in their daily lives. Designing prostheses that can effectively adapt to varying terrain remains an ordeal to …
-
An implantable micro-system for neural prosthesis control and sensory feedback restoration in amputees
… the Peripheral Nervous System (PNS) and a neuro-controlled hand prosthesis is presented. The system is composed of two Integrated Circuits (ICs): a standard CMOS device for neural recording and a High Voltage (HV) CMOS device for neural stimulation. The integrated circuits have been realized in …
-
Data and Sensor Fusion Using FMG, sEMG and IMU Sensors for Upper Limb Prosthesis Control
… more functionality, but the methods available to control these prostheses restrict their use to simple actions, and are part of the reason why users often reject prosthetic technologies. Using multiple myography modalities has been a promising approach to address these control limitations; …
-
Flexible Electronics for High-Density EMG Based Signal Acquisition for Upper Limb Myoelectric Prosthesis Control
… developing flexible electrodes for high-density control of an upper limb myoelectric prosthesis. Different flexible dry electrode materials (made from doped traditionally non-conductive substrates) were used and compared to titanium (which is the industry standard for EMG electrodes). We …
-
User- and Speed-Adaptability Enhancement of User Gait Phase Estimation for Robotic Transfemoral Prosthesis Control
… interacting factor. Because the user and the prosthesis should be treated as a coupled system, synchronized prosthesis control is required for stable walking and proper assistance. Researchers attempted to estimate user gait progression based on heel-strike, but this method is not adaptable to …
Page 1 of 3