Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 43 for “"Prosthetic Heart Valves"”.

  1. Hydrodynamic performance of mechanical and biological prosthetic heart valves

    … been the ability to replace severely diseased heart valves with prosthetic ones. The option of using prosthetic heart valves for the treatment of valvular diseases has improved and prolonged many lives. This is reflected in around 120,000 heart valve replacement operations carried out every …

    ubc Repository record for Hydrodynamic performance of mechanical and biological prosthetic heart valves (opens in a new tab) Download PDF for Hydrodynamic performance of mechanical and biological prosthetic heart valves (opens in a new tab)

  2. Magnetic retrieval of prosthetic heart valves for redo-TAVI

    … life expectancy and the low durability of bioprosthetic valve replacements, the number of patients requiring multiple redo aortic valve replacements are on the rise. For patients unable to undergo open heart surgery, the only current option for redo valve replacement is the Valve-in-Valve …

    soton Repository record for Magnetic retrieval of prosthetic heart valves for redo-TAVI (opens in a new tab) Download PDF for Magnetic retrieval of prosthetic heart valves for redo-TAVI (opens in a new tab)

  3. Computer vision based performance analysis of prosthetic heart valves

    Prosthetic heart valves (PHVs) are routinely used to replace defective native heart valves in patients suffering from valvular heart diseases. While PHVs are life-saving, they have limitations in performance and durability. Therefore, it is crucial to rigorously test and evaluate their designs …

    uvic Repository record for Computer vision based performance analysis of prosthetic heart valves (opens in a new tab)

  4. Innovative non-isocyanate polyurethanes for customized prosthetic heart valves

    … non-isocyanate polyurethanes for customized prosthetic heart valves, began with the primary goal of developing new polymeric heart valve prostheses, a need that has been identified over the past few years. Indeed, the effective treatment for most patients with heart valve disease is valve …

    liege Repository record for Innovative non-isocyanate polyurethanes for customized prosthetic heart valves (opens in a new tab) Restricted access

  5. A minimally invasive system for the evaluation of prosthetic heart valves

    … for detecting [single-leg separation of the heart valve strut] failures. The feasibility of the method is investigated using three-dimensional finite element analysis techniques.

    msu Repository record for A minimally invasive system for the evaluation of prosthetic heart valves (opens in a new tab)

  6. An intelligent computerized pulse-duplicator for the in-vitro evaluation of prosthetic heart valves

    … determination of the hydrodynamic performance of prosthetic heart valves. High speed data acquisition and ensemble averaging techniques are employed to minimize error and provide a standard for data collection and analysis across a wide range of simulated physiologic conditions. Processing …

    njit Repository record for An intelligent computerized pulse-duplicator for the in-vitro evaluation of prosthetic heart valves (opens in a new tab)

  7. An In Vitro Investigation of the Flow Fields Through Bileaflet and Polymeric Prosthetic Heart Valves

    Current designs of bileaflet mechanical heart valves (BMHVs) and trileaflet polymeric heart valves(TPHVs) are plagued by unacceptable levels of hemolysis and thrombus formation in critical areas thereby producing mediocre clinical performance. The objective of this study is: (1) to investigate the …

    gatech Repository record for An In Vitro Investigation of the Flow Fields Through Bileaflet and Polymeric Prosthetic Heart Valves (opens in a new tab)

  8. The use of multi-level modelling to investigate the hydrodynamic function of polyurethane prosthetic heart valves

    … here is the statistical comparison of prosthetic valve hydrodynamic function data. Such data has, until now, been presented in a subjective way, with selection of valves for demonstration of the desired behaviour. Few attempts have been made at objective analysis of such data. The data …

    glasgow Download PDF for The use of multi-level modelling to investigate the hydrodynamic function of polyurethane prosthetic heart valves (opens in a new tab)

  9. In vitro fluid dynamics of the Bjork-Shiley monostrust mitral disc valve using laser doppler anemometry

    In recent decades, several different types of prosthetic devices have been introduced in clinical practice to replace the diseased natural heart valves. In Canada alone, around 10,000 operations aimed at treatment of valvular diseases are carried out every year. Although evolution of prosthetic …

    ubc Repository record for In vitro fluid dynamics of the Bjork-Shiley monostrust mitral disc valve using laser doppler anemometry (opens in a new tab) Download PDF for In vitro fluid dynamics of the Bjork-Shiley monostrust mitral disc valve using laser doppler anemometry (opens in a new tab)

  10. Optimizing bioprosthetic heart valves using isogeometric analysis and surrogate modeling

    … analyze the aortic valvular disease and develop prosthetic heart valves. Optimization is an efficient solution to improve prosthetic heart valve performance. This thesis aims to optimize the bioprosthetic heart valve design to increase the coaptation area during the diastole and the orifice area …

    iastate Repository record for Optimizing bioprosthetic heart valves using isogeometric analysis and surrogate modeling (opens in a new tab)

  11. Development, testing, and evaluation of the central-flow, double- leaflet heart valve

    A review of the literature revealed that 1) all prosthetic heart valves to date are plagued by certain problems, 2) all prosthetic valves in current clinical use are central-occlusion valves which do not effectively simulate natural valve action, and 3) the development of a true central-flow valve …

    vt Repository record for Development, testing, and evaluation of the central-flow, double- leaflet heart valve (opens in a new tab)

  12. Early prototyping and testing of a model of an expandable heart valve apparatus for paediatric deployment

    Valvular heart disease is any abnormal condition which involves one or more of the heart valves - the aortic and mitral valves on the left and the pulmonary and tricuspid valves on the right. Valves diseases in infants are congenital and their effect is to burden the heart with an increased work to …

    strathclyde Repository record for Early prototyping and testing of a model of an expandable heart valve apparatus for paediatric deployment (opens in a new tab)

  13. Use of Affimers for Targeting S. aureus Biofilms

    … is an infection of the lining of the native or prosthetic heart valves. These infections can be debilitating, even life-threatening, and are often difficult to diagnose clinically. S. aureus grows on the surfaces of medical devices and natural tissues as a biofilm. Bacteria in biofilms can be …

    whiterose Download PDF for Use of Affimers for Targeting S. aureus Biofilms (opens in a new tab)

  14. Towards a 3D printed patient clone: Application to the effect of aortic regurgitation on the flow in the left ventricle

    Heart disease is the leading cause of death in the world. Amongst the many cardiovascular diseases, heart valve failure is a common reoccurrence. Patient safety has risen to being a top priority focus for every field of medicine therefore heart simulators are implemented and expected to contribute …

    concordia Download PDF for Towards a 3D printed patient clone: Application to the effect of aortic regurgitation on the flow in the left ventricle (opens in a new tab)

Page 1 of 3