Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 15 of 15 for “"Prosthetic Joints"”.

  1. Tribology of prosthetic joints : validation of wear simulation methods

    In hip and knee arthroplasty, loosening of prosthetic components is the principal reason for expensive and complicated reoperations. Loosening is believed to be caused mainly by tissue reactions to wear particles removed from ultrahigh molecular weight polyethylene bearing surfaces. The tissue …

    aalto Repository record for Tribology of prosthetic joints : validation of wear simulation methods (opens in a new tab)

  2. Mediators of localised pathological bone loss / Tania N. Crotti.

    … bone loss, with the focus on bone loss around prosthetic joints in periodontal disease and rheumatoid arthritis. It explores the possibility that bone resorption that is not balanced by bone formation is caused by an abnormal expression of factors that regulate osteoclast formation and activity …

    adelaide Repository record for Mediators of localised pathological bone loss / Tania N. Crotti. (opens in a new tab)

  3. Highly functional biomaterial coatings for the prevention of medical device-associated infections

    … and vascular catheters, endotracheal tubes and prosthetic joints are essential in modern healthcare for patient management, but by bypassing natural defence barriers, they increase the risk of device-associated infections such as catheter-associated urinary tract infections, central …

    qu-belfast Repository record for Highly functional biomaterial coatings for the prevention of medical device-associated infections (opens in a new tab) Embargoed until 2031-12-31

  4. Morphological Characterization of Irradiated Ultra High Molecular Weight Polyethylene (UHMWPE)

    … Weight Polyethylene (UHMWPE) is studied for prosthetic joints and for radiation shielding for manned space missions. The first section of the dissertation will cover gamma radiation effects on UHMWPE by means of solubility, hardness, three-phase model, crystallite thickness, and molecular …

    utk-theses Repository record for Morphological Characterization of Irradiated Ultra High Molecular Weight Polyethylene (UHMWPE) (opens in a new tab)

  5. Design and Evaluation of a Microprocessor-Controlled Powered Hip Prosthesis

    … create ambulation difficulties and current prosthetic solutions are limited. Powered prosthetic joints have successfully improved lower limb amputee gait; however, no powered hip joints are available on the market. This thesis presents the design and evaluation of a microprocessor-controlled …

    ottawa-retro Repository record for Design and Evaluation of a Microprocessor-Controlled Powered Hip Prosthesis (opens in a new tab)

  6. Developing Implantable Hydrogel-Based Sensors to Measure Biomarkers in Synovial Joint Fluid Using Plain Radiography

    … surgeries are generally successful, about 1% of prosthetic hips become infected. If the infections are not detected and treated promptly with antibiotics and surgical debridement, device removal is almost always required to treat the infections. Therefore, it’s important to detect post-surgery …

    clemson Repository record for Developing Implantable Hydrogel-Based Sensors to Measure Biomarkers in Synovial Joint Fluid Using Plain Radiography (opens in a new tab)

  7. Online Parameter Adaptation of LQR Controllers via RLS for Prosthetic Joint Control: Experimental Validation on a Quanser Qube-Servo 2 Platform

    … Quadratic Regulator (LQR) control method for prosthetic joint systems using Recursive Least Squares (RLS)-based real-time parameter estimation on the Quanser QUBE-Servo 2 platform. Traditional LQR controllers assume a fxed system model, which limits adaptability and results in reduced tracking …

    columbus-state Repository record for Online Parameter Adaptation of LQR Controllers via RLS for Prosthetic Joint Control: Experimental Validation on a Quanser Qube-Servo 2 Platform (opens in a new tab)

  8. The Effect of Antibiotic Prophylaxis on Infection Rates in Mohs Micrographic Surgery: A Single-institution Retrospective Study

    … in preventing surgical site infection, prosthetic joint infection, infective endocarditis, and specifics regarding administration. OBJECTIVE: The objective of this study is to describe the effect of antibiotic prophylaxis (AP) in Mohs micrographic surgery (MMS) on infective endocarditis, …

    utswmed Repository record for The Effect of Antibiotic Prophylaxis on Infection Rates in Mohs Micrographic Surgery: A Single-institution Retrospective Study (opens in a new tab)

  9. The Invisible Force: Optimizing Novel Approaches in Anesthesiology and Infectious Diseases

    … S. aureus grown on steel washers to simulate prosthetic joints, we were able to intermittently deliver 3s pulses for 15, 30, or 60 minutes to reduce bacterial load. Combined treatment with AMF and ceftriaxone (or linezolid) showed a 5-log decrease in bacterial load after 24 hours, whereas …

    utswmed Repository record for The Invisible Force: Optimizing Novel Approaches in Anesthesiology and Infectious Diseases (opens in a new tab)

  10. Numerical modeling of chiral and achiral liquid crystals in confined geometries

    … their lubricating properties to develop advanced prosthetic joints. Overall, the thesis significantly advances the theoretical understanding of LC flow in various confined geometries. These contributions enhance fundamental knowledge and have profound practical implications for multiple …

    ubc Repository record for Numerical modeling of chiral and achiral liquid crystals in confined geometries (opens in a new tab) Download PDF for Numerical modeling of chiral and achiral liquid crystals in confined geometries (opens in a new tab)

  11. Design and Evaluation of Walking, Sit-To-Stand, and Stand-To-Sit Control Strategies for a Hip-Knee-Ankle-Foot Prosthesis with Motorized Hip Joint

    … effective use. Despite advancements in motorized prosthetic joints for the knee and ankle, innovation for HKAF prostheses has stagnated. This thesis addresses this gap by developing and evaluating adaptive control strategies for a motorized HKAF prosthesis to enhance mobility for HD amputees. …

    ottawa-retro Repository record for Design and Evaluation of Walking, Sit-To-Stand, and Stand-To-Sit Control Strategies for a Hip-Knee-Ankle-Foot Prosthesis with Motorized Hip Joint (opens in a new tab)

  12. Periprosthetic Joint Infections. Clinical and Epidemiological Aspects.

    … or enterococci in sterile cultures from prosthetic joints were included and data from the medical records were reviewed retrospectively. The aim was to describe the affected populations, surgical and antimicrobial treatments and treatment outcome. Paper I showed that streptococcal PJIs …

    lund Repository record for Periprosthetic Joint Infections. Clinical and Epidemiological Aspects. (opens in a new tab) Download PDF for Periprosthetic Joint Infections. Clinical and Epidemiological Aspects. (opens in a new tab)

  13. Development and Evaluation of Anti-Bacterial Surfaces and Coatings for Medical Devices and Implants

    … such as fracture fixators, urinary catheters, prosthetic heart valves and prosthetic joints are intensively used in hospitals nowadays. However, medical devices and implants suffer from biofilm problem, which may result in serious complications and expensive care burden. According to the …

    dundee Repository record for Development and Evaluation of Anti-Bacterial Surfaces and Coatings for Medical Devices and Implants (opens in a new tab) Download PDF for Development and Evaluation of Anti-Bacterial Surfaces and Coatings for Medical Devices and Implants (opens in a new tab)

  14. Effect of Composition on Periprosthetic Fluid Rheology and Friction in Total Knee Arthroplasty

    The present thesis investigates the friction properties of total knee replacement components using lubricating fluids of different composition and rheology. The first stage of the thesis involves characterization of the rheological properties of hyaluronic acid (HA)/bovine calf serum (BCS) …

    queens Repository record for Effect of Composition on Periprosthetic Fluid Rheology and Friction in Total Knee Arthroplasty (opens in a new tab)

  15. The effects of prosthetic alignment on the stability of the knee in above knee amputees

    … measuring system were used for measuring the prosthetic alignment accurately. Three TV cameras and two Kistler force plates were operated simultaneously and synchronously at a rate I of 50 Hz to acquire the displacements of the body segments and the ground reaction forces. All angular …

    strathclyde Repository record for The effects of prosthetic alignment on the stability of the knee in above knee amputees (opens in a new tab)