Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 41 for “"Prosthetic Sockets"”

  1. Prosthetic Sockets: Assessment of Thermal Conductivity

    Current commercially available prosthetic liners and sockets insulate the residual limb, causing the temperature of the residual limb to increase. As a result, the residual limb sweats excessively, leading to numerous dermatologic conditions. These skin problems can impart physical and …

    ohiolink Repository record for Prosthetic Sockets: Assessment of Thermal Conductivity (opens in a new tab)

  2. The computer-aided design of below-knee prosthetic sockets.

    … which was developed at UCL to design below-knee prosthetic sockets. The first objective in the system's development was to provide an automated facility capable of taking surface measurements of a residual limb and manipulating these data to produce a socket shape using conventional design …

    ucl Repository record for The computer-aided design of below-knee prosthetic sockets. (opens in a new tab)

  3. The computer aided design of below-knee prosthetic sockets

    … which was developed at UCL to design below-knee prosthetic sockets. The first objective in the system's development was to provide an automated facility capable of taking surface measurements of a residual limb and manipulating these data to produce a socket shape using conventional design …

    ucl Repository record for The computer aided design of below-knee prosthetic sockets (opens in a new tab)

  4. Stiffness-Tailored Digital Materials for Additively Manufactured Prosthetic Sockets

    … methods for tuning mechanical properties in prosthetic sockets for improving patient comfort. One such technology, multi-material 3-D printing, enables the manufacturing of complex multi-material structures. By discretizing a structure into voxels, material placement can be digitally defined, …

    carleton Repository record for Stiffness-Tailored Digital Materials for Additively Manufactured Prosthetic Sockets (opens in a new tab)

  5. Advanced prototyping of variable impedance prosthetic sockets for trans-tibial amputees : polyjet matrix 3D printing of comfortable prosthetic sockets using digital anatomical data

    … evaluates the design of a Variable Impedance Prosthetic (VIPr) socket for a transtibial amputee using computer-aided design and manufacturing (CAD/CAM). Compliant features are seamlessly integrated into a 3D printed socket to achieve lower interface peak pressures over bony protuberances by …

    mit Repository record for Advanced prototyping of variable impedance prosthetic sockets for trans-tibial amputees : polyjet matrix 3D printing of comfortable prosthetic sockets using digital anatomical data (opens in a new tab)

  6. Modeling and fabrication of prosthetic sockets using selective laser sintering

    … amputees involves effective fitting of prosthetic components. However, conventional techniques used to produce sockets with suitable characteristics are labor intensive and expensive, and depend on the work of skilled prosthetists that are relatively scarce compared to the number of …

    texas Repository record for Modeling and fabrication of prosthetic sockets using selective laser sintering (opens in a new tab)

  7. Design and Optimisation of Transtibial Prosthetic Sockets to Reduce Tissue Damage

    … diabetes, this number is expected to increase. Prosthetics offer a means of rehabilitation for those who have suffered an amputation. Current efforts prioritise the development of these technologies to improve comfort and reduce costs. This thesis presents a multidisciplinary framework for …

    bristol Repository record for Design and Optimisation of Transtibial Prosthetic Sockets to Reduce Tissue Damage (opens in a new tab)

  8. Fluidic Flexible Matrix Composite Wafers for Volume Management in Prosthetic Sockets

    … goal of this research is to develop smart prosthetic sockets that can accommodate for volume fluctuations in the residual limb. In this research, fluidic flexible matrix composite wafers (f2mc) are integrated into the prosthetic socket for volume regulation. The f2mc's are flexible tubular …

    vt Repository record for Fluidic Flexible Matrix Composite Wafers for Volume Management in Prosthetic Sockets (opens in a new tab)

  9. Development Of A Verified Distal End For 3D-Printed Transtibial Prosthetic Sockets

    Background: An ideal lower limb prosthetic socket should be comfortable and durable while minimizing weight; optimizing socket designs for these goals can prove difficult due to the bespoke nature of definitive sockets. ISO 10328 is designed to verify the strength and durability of engineered …

    umn Repository record for Development Of A Verified Distal End For 3D-Printed Transtibial Prosthetic Sockets (opens in a new tab)

  10. Modeling and design of perforated prosthetic sockets ARCHM to increase heat transfer of residual limbs

    Heat build-up in prosthetic sockets is a significant problem experienced by many amputees in America, with no central solution in sight. Heat and discomfort accounts for over 70% of problems experienced by lower limb amputees in America. Although there have been advances in prosthetics in the …

    mit Repository record for Modeling and design of perforated prosthetic sockets ARCHM to increase heat transfer of residual limbs (opens in a new tab)

  11. Design and verification of a finite element analysis model for predicting deflection of actively actuated prosthetic sockets

    … to secure the pylon to the socket, and a prosthetic foot. For the prosthesis to be effective, the socket must be comfortable, functional and aesthetically appealing, usually in that order. Lack of comfort and fit can cause movement problems and health issues. The residual limb of the …

    texas Repository record for Design and verification of a finite element analysis model for predicting deflection of actively actuated prosthetic sockets (opens in a new tab)

  12. Characterization of 3D Printed Lattice Structures Used in the Design of Modified Compression Release Stabilized Transhumeral Prosthetic Sockets

    Abstract A prosthetic socket is the critical interface between a person and their prosthetic device. Pressure, shear, and friction experienced by the residual limb from wearing a socket can damage soft tissue. While Compression Release Stabilized (CRS) style sockets are beneficial for enhancing …

    rit Repository record for Characterization of 3D Printed Lattice Structures Used in the Design of Modified Compression Release Stabilized Transhumeral Prosthetic Sockets (opens in a new tab)

  13. New filament deposition technique for high strength ductile 3D printed parts

    … and expertise. Current methods of lower limb prosthetic socket fitting and fabrication are too expensive, labor intensive, and dependent on highly skilled technicians, and thus are not suitable to properly serve patients in rural, impoverished areas, particularly in developing countries. …

    texas Repository record for New filament deposition technique for high strength ductile 3D printed parts (opens in a new tab)

  14. Modelling thermoregulation for prosthetic design

    Conventional manufacture of prosthetic sockets is artisanal, relying on limited objective data, which often leads to discomfort and tissue damage. Thermal discomfort is a key concern identified by amputees, particularly in hot climates. Despite this, it has had little research attention. This …

    oxford Repository record for Modelling thermoregulation for prosthetic design (opens in a new tab)

  15. Bending strength test and evaluation of a transtibial prosthetic socket fabricated by selective laser sintering

    Transtibial prosthetic sockets made using selective laser sintering (SLS) of Duraform (™) PA have no documented failure data. In order to produce prostheses with safe weight and usage limits, a non-standard bending test was needed to determine the maximimi safe loading of the socket and to …

    nps Repository record for Bending strength test and evaluation of a transtibial prosthetic socket fabricated by selective laser sintering (opens in a new tab)

  16. Socket Fit Matters: Development of a Novel Marker Model to Assess How Localised Adjustments in Transtibial Socket Shape Affect Prosthetic Coupling

    In lower-limb prosthetics, what produces a good-fitting prosthetic socket is loosely defined. Although common socket rectifications are known and the change in residuum volume to create a poor fit has been estimated, determining the quality of a prosthetic fit lies entirely in the hands of the …

    salford Repository record for Socket Fit Matters: Development of a Novel Marker Model to Assess How Localised Adjustments in Transtibial Socket Shape Affect Prosthetic Coupling (opens in a new tab)

  17. Socket Fit Matters: Development of a Novel Marker Model to Assess How Localised Adjustments in Transtibial Socket Shape Affect Prosthetic Coupling

    In lower-limb prosthetics, what produces a good-fitting prosthetic socket is loosely defined. Although common socket rectifications are known and the change in residuum volume to create a poor fit has been estimated, determining the quality of a prosthetic fit lies entirely in the hands of the …

    salford Repository record for Socket Fit Matters: Development of a Novel Marker Model to Assess How Localised Adjustments in Transtibial Socket Shape Affect Prosthetic Coupling (opens in a new tab)

  18. Adaptação eletrônica de um leitor mecânico de coto, investigação e desenvolvimento de interface CAD

    … processes of both transfemural and transtibial prosthetic sockets. The key point for this task is to customize these readings trying to be as faithful as possible to the real profile of each patient. Within this context, firstly two prototype versions (α and β) of a 3D mechanical scanner for …

    brazil-ufrn Repository record for Adaptação eletrônica de um leitor mecânico de coto, investigação e desenvolvimento de interface CAD (opens in a new tab)

  19. Probing the Spatial Acuity of the Thigh for Enhanced Sensory

    … Embedding tactile displays in transfemoral prosthetic sockets to convey movement cues through varied vibration patterns is seen as a promising avenue. To optimize the functionality of such displays, it is essential to determine the minimum distance required to discriminate between two …

    guelph Repository record for Probing the Spatial Acuity of the Thigh for Enhanced Sensory (opens in a new tab)

Page 1 of 3