Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 25 for “"Protection Coordination"”.

  1. Protection coordination study in bhutan transmission network

    … one of the most important requirements of protection system is to isolate and disconnect faulted parts of the system selectively and quickly. This purpose can be achieved by proper coordination of protective devices. One of the aims of this thesis was to make a general guideline from which …

    chalmers Repository record for Protection coordination study in bhutan transmission network (opens in a new tab)

  2. Distribution Systems Optimal Power Outage Restoration Enhancement through the Application of State Estimation and Protection Coordination Analysis

    … SE to then perform fault location and isolation, protection miscoordination detection and correction, optimal restoration, and restoration switching sequence. Even though compounded by time-consuming features, the solution is designed to present time efficiency while also accounting for …

    ttu Repository record for Distribution Systems Optimal Power Outage Restoration Enhancement through the Application of State Estimation and Protection Coordination Analysis (opens in a new tab)

  3. Analysis of Protection Coordination in Substations of SPEC’s Distribution System and the Renewable Energy Sources Integration Impact

    The protection coordination in distribution networks can be achieved by applying the appropriate coordination techniques to the protective device of concern. Fuses, reclosers, and relays are the most common devices utilized in overcurrent-based protection schemes that are part of the main circuits …

    ttu Repository record for Analysis of Protection Coordination in Substations of SPEC’s Distribution System and the Renewable Energy Sources Integration Impact (opens in a new tab)

  4. Impacts of Solar Photovoltaic on the Protection System of Distribution Networks - A case of the CIGRE low voltage network and a typical medium voltage distribution network in Sweden

    … from the supply to the customer end. Overcurrent protection coordination for passive radial networks is based upon single direction power flow. When distributed generation (DG) is present in these networks, the current flows from the customer end as well. This current flow distorts the original …

    chalmers Repository record for Impacts of Solar Photovoltaic on the Protection System of Distribution Networks - A case of the CIGRE low voltage network and a typical medium voltage distribution network in Sweden (opens in a new tab)

  5. Modeling and Analysis of Cal Poly Microgrid

    … microgrid. Additionally, an ETAP power system protection tutorial is created to aid students entering the power industry. Microprocessor-based relays are heavily utilized in both the ETAP model and hardware implementation of the system. Case studies in this project investigate electric power …

    calpoly Repository record for Modeling and Analysis of Cal Poly Microgrid (opens in a new tab)

  6. An Investigation of the Utilization of Smart Meter Data to Adapt Overcurrent Protection for Radial Distribution Systems with a High Penetration of Distributed Generation

    … systems and the major philosophies of their protection, namely, selectivity and sensitivity, were easily achieved. Settings for overcurrent protective devices (OCPDs) were static and based on the maximum load downstream of its location, with little concern of major configuration changes. …

    tamu Repository record for An Investigation of the Utilization of Smart Meter Data to Adapt Overcurrent Protection for Radial Distribution Systems with a High Penetration of Distributed Generation (opens in a new tab)

  7. Active, Controllable Overvoltage and Overcurrent Protection Devices for Power Systems with High Inverter-Based Resource Domination

    … significant challenges to modern power system protection devices. For OCP, the fault current magnitude is significantly limited and variable due to the inherent current limiting of inverters and the diversity of IBR connectivity during a fault. As a result, OCP devices must intelligently detect …

    gatech Repository record for Active, Controllable Overvoltage and Overcurrent Protection Devices for Power Systems with High Inverter-Based Resource Domination (opens in a new tab)

  8. Protection of distribution networks with distributed generation

    … voltage regulation, power system stability and protection coordination can be affected due to connection of DG to DNs. The purpose of this dissertation is to investigate the potential impact of DG on the protection setup of DNs and to suggest solutions to solve these problems for safe …

    soton Download PDF for Protection of distribution networks with distributed generation (opens in a new tab)

  9. Modeling and Analysis of a Hybrid AC/DC Green Seaport Power System with Photovoltaic Generation and Battery Energy Storage Systems

    … energy storage systems (BESS), and coordinated protection within a hybrid AC/DC framework. The work improves a previously established model, enhancing it with detailed protection studies and simultaneous AC/DC power flow analysis using EasyPower software. The system was evaluated under a wide …

    calpoly Repository record for Modeling and Analysis of a Hybrid AC/DC Green Seaport Power System with Photovoltaic Generation and Battery Energy Storage Systems (opens in a new tab)

  10. Optimum coordination of directional overcurrent relays in a distribution network with distributed generation

    The conventional relay protection coordination method is mainly used in the industry to calculate the protective overcurrent relay settings. The conventional method requires many inputs and does not produce the best relay coordination results. When there are multiple sources, the calculation …

    nwu-za Repository record for Optimum coordination of directional overcurrent relays in a distribution network with distributed generation (opens in a new tab)

  11. Distributed Electric Aircraft Propulsion Architectures with Fault Protection Strategy

    … research in this thesis is the development of a protection coordination strategy for the DEAP system that includes, current limiting and I2t based strategies. DEAP systems utilize the DC bus system at higher voltage levels than conventional systems ranging from +/- 0.5 kV to +/-5 kV. In addition …

    houston Repository record for Distributed Electric Aircraft Propulsion Architectures with Fault Protection Strategy (opens in a new tab)

  12. New methods for protection of future power networks incorporating high penetrations of distributed generation

    … the system can affect the operation of network protection, and with the continuing increase in generation, the impact on protection operation is expected to grow. In this thesis, the growing impact of inverter-interfaced generation on distribution network protection is investigated. Initially, …

    strathclyde Repository record for New methods for protection of future power networks incorporating high penetrations of distributed generation (opens in a new tab)

  13. MITIGATION OF SYNCHRONOUS MACHINE BASED DISTRIBUTED GENERATION INFLUENCES ON FUSE-RECLOSER PROTECTION SYSTEMS IN RADIAL DISTRIBUTION NETWORKS USING SUPERCONDUCTING FAULT CURRENT LIMITERS

    … effects on existing radial fuse-recloser protection infrastructure. The mitigation method provides a comparative analysis of the utilization of resistive (R), inductive (L) and resonant (LC) type superconducting fault current limiters (FCLs) for prevention of excessive fault current …

    sask Repository record for MITIGATION OF SYNCHRONOUS MACHINE BASED DISTRIBUTED GENERATION INFLUENCES ON FUSE-RECLOSER PROTECTION SYSTEMS IN RADIAL DISTRIBUTION NETWORKS USING SUPERCONDUCTING FAULT CURRENT LIMITERS (opens in a new tab)

  14. Asymmetrical operation of EHV transmission lines

    … converter capacity, control functionality, protection coordination, operational procedures, and techno-economic justification. Therefore, the contribution of this thesis is not to establish immediate practical deployment of AO, but to provide a physically grounded simulation framework and …

    strathclyde Repository record for Asymmetrical operation of EHV transmission lines (opens in a new tab)

  15. Voltage Management Of Distribution Networks With High Penetration Of Distributed Photovoltaic Generation Sources

    … electrical systems. Issues such as voltage rise, protection coordination, islanding detection, harmonics, increased or changed short-circuit levels, etc., need to be carefully addressed before we can see a wide adoption of this environmentally friendly technology. Voltage rise or overvoltage …

    wayne-thes Repository record for Voltage Management Of Distribution Networks With High Penetration Of Distributed Photovoltaic Generation Sources (opens in a new tab)

  16. Development of a current limiting solid-state circuit breaker based on wide-band gap power semiconductor devices for 400V DC microgrid protection

    … this trend is the lack of effective DC fault protection devices/circuits. Although conventional electromechanical circuit breakers work well in AC systems, they are not suitable for DC systems due to their long response time (ranging from tens of milliseconds to hundreds of milliseconds). Such …

    whiterose Download PDF for Development of a current limiting solid-state circuit breaker based on wide-band gap power semiconductor devices for 400V DC microgrid protection (opens in a new tab)

  17. Short circuit modeling of wind turbine generators

    … equipment ratings and to provide data for protection coordination. The plethora of different factors that influence the response of wind farms to short circuits makes short circuit modeling of wind farms an interesting, complex, and challenging task. Low voltage ride through (LVRT) …

    sask Repository record for Short circuit modeling of wind turbine generators (opens in a new tab)

  18. Fault Aware Soft Restart of an Islanded Microgrid Using an Inverter Coupled Energy Storage System

    … without the need to re-engineer the existing protection coordination in the distribution system. Fault detection based on voltage measurements from the inverter terminals are used to detect a fault and isolate the energy storage-powered facility with negligible power feed into the fault. The …

    south-carolina Repository record for Fault Aware Soft Restart of an Islanded Microgrid Using an Inverter Coupled Energy Storage System (opens in a new tab)

Page 1 of 2