Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 53 for “"Protection Relay"”.
-
Software framework for protection relay testing
… comprehensive automated testing of power system protection relays. This application was implemented using a model protection system that was designed to simulate actual relaying operations performed in the electric power system. The implemented application provided automated testing functionality …
-
Effect of STATCOM Location on Distance Protection Relay Operation
… up some difficulties to conventional distance protection to meet basic requirements for protection schemes. This dissertation reviews FACTS concepts, and studies shunt-connected STATCOM and its modelling. Based on the dynamic behaviour of STATCOM in a two-machine system, where a distance …
-
Impacts of midpoint FACTS controllers on the coordiantion between generator phase backup protection and generator capability limits
… and SVC) on the generator distance phase backup protection in order to identify important issues that protection engineers need to consider when designing and setting a generator protection system. In addition, practical, feasible and simple solutions to mitigate the adverse impact of midpoint …
-
Development of a new pole–slip protection function for synchronous machines
… during a pole-slip condition. All pole-slip protection relays currently on the market use the impedance pole-slip protection method to detect a pole-slip. No commercial relay currently available can predict accurately when a generator is about to experience a damaging pole-slip. All the …
-
Adaptive Reconfiguration of Protection Relays to Accommodate Distributed
… (DGs) requires the reconfiguration of the protection system of the distribution network (DN) in place. Increased integration of DGs in the DN can cause incorrect tripping and false non-tripping of the overcurrent (OC) protection relays in the DN as well as increased possibilities of faults …
-
Real tIme simulation of a microgrid system with distributed energy resources
… required for studying the operation, control and protection issues related to microgrids. A real-time simulation model of a medium voltage microgrid with distributed energy re-sources (DERs) was developed using the RTDS real-time digital simulator. The DERs in this microgrid include a diesel …
-
Implementation of an IEC 61850 Sampled Values Based Line Protection IED with a New Transients-Based Hybrid Protection Algorithm
… an IEC 61850 sampled values based line protection Intelligent Electronics Device (IED) on a desktop computer. This IED is capable of subscribing, decoding and processing the sampled values published by a source to be used in line protection algorithms. The novel hybrid line protection …
-
Real-time modeling, simulation and analysis of a grid connected PV system with hardware-in-loop protection.
… Furthermore, the model is interfaced with protection relay testing equipment to simulate hardware-in-the-loop testing.
-
Microgrid Laboratory Wind Energy Integration
… laboratory with various generators, loads, and protection systems over the past several years. To improve and make the Cal Poly microgrid laboratory more realistic, this thesis outlines the process of improving the EE microgrid setup by adding a wind energy generation system via an induction …
-
GridFormer - A New Approach to Stabilize and Manage a Higher IBR Penetration Grid
… converter, a small energy storage unit, and a protection relay capable of handling high fault currents. It provides both series voltage and shunt current to stabilize frequency and voltage during grid events, offering improved reliability compared to traditional FACTS devices. A prototype of …
-
Computer aided design of protection systems for electrical drives
… aided design (CAD) may be applied to the protection systems of electrical drives, removing much of the repetitive procedures presently used in determining relay settings. To further this aim, a series of algorithms have been devised which allow exploitation of the concept. The areas chosen …
-
INSTRUMENTATION CHANNEL ERROR CORRECTION AND ITS EFFECTS ON PROTECTIVE RELAYS
… and to investigate its effects on protective relays. The physically-based high fidelity models of entire instrumentation channel are developed, which consist of the instrument transformer, the instrumentation cable and the burden resistor. A dynamic state estimation algorithm is constructed to …
-
IMPACT OF WIND ENERGY CONVERSION SYSTEMS ON GENERATOR DISTANCE PHASE BACKUP PROTECTION
… performance of generator distance phase backup protection (Relay (21)) and the generator capability curves. In this context, comprehensive studies are conducted on a sample power system incorporating large DFIG- and FFC-based wind farms tapped to the transmission system. The results of these …
-
Wide Area Measurement Applications for Improvement of Power System Protection
… that occur when the system is under stress, the protection systems are susceptible to mis-operation. It is under such severe situations that the network cannot afford to lose its critical elements like the main generation units and transmission corridors. In addition to the slow but steady …
-
Design and Implementation of Overcurrent Protection Relays Test Bench
… employed electromechanical and microprocessor protection relays, manual isolation and industrial circuit breakers, switches, variable autotransformer (VARIAC), voltmeters and ammeters. During the dismantling, a lot of equipment was retrieved for future possible use. This led to the idea of …
-
Using the IEEE C37.118 Protocol to Add Hardware in the Loop to the CYPRES Testbed
… protocol and output actual voltage signals to a relay protection system. In this way, the relay can be tested and perform actions as if it were connected to a full-scale power grid network. This was accomplished by utilizing PowerWorld Dynamic Studio (PWDS) for the power grid simulator, National …
-
110 kV Linijų distancinės apsaugos tyrimas /
Current productions of remote protection are set for simplification of its construction and amplification of reliability. Despite some shortcomings, remote protection is the best protection from interleg short circuits in order to protect lines of high voltage and still remain with the proper and …
-
A study of the effect of harmonics in the system on the performance of residual current-operated circuit-breakers and electromechanical overcurrent relays
… (RCCBs) have proved useful devices for the protection of both human beings against ventricular fibrillation and installations against fire. Although they work well with sinusoidal waveforms, there is little published information on their characteristics. Due to shunt connected non-linear …
Page 1 of 3