Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 114 for “"Protein separation"”.

  1. Protein separation with mathematical modeling for chromatographic operation

    … columns used for liquid phase chromatographic separations of proteins with impulse input of feed solutions. These models can now be used to describe the relationships between the elution characteristics (peak height, peak position, and shapes) and the operating conditions (flow rate and buffer …

    njit Repository record for Protein separation with mathematical modeling for chromatographic operation (opens in a new tab)

  2. PAMAM Dendrimer Modified Microporous PVDF Membranes for Protein Separation

    In this PhD thesis, the process of protein separation using PAMAM dendrimer-modified PVDF membranes was systematically studied. By selecting different KOH alkaline solutions, PAMAM was immobilized either on the surface of the PVDF membrane (treated with KOH aqueous solution) or simultaneously on …

    ottawa-retro Repository record for PAMAM Dendrimer Modified Microporous PVDF Membranes for Protein Separation (opens in a new tab)

  3. Planar electrochromotography and electromembrane protein separation using nanoporous alumina materials

    … and on-line planar electrochromatography protein separation. Protein separation condition was optimized by varying alumina pore size, pore depth, surface properties as well as the pH value of buffer solution. The mechanism of planar electrochromatography protein separation was studied. …

    nus Repository record for Planar electrochromotography and electromembrane protein separation using nanoporous alumina materials (opens in a new tab) Download file for Planar electrochromotography and electromembrane protein separation using nanoporous alumina materials (opens in a new tab)

  4. Protein Separation and Label-Free Detection on Supported Lipid Bilayers

    Membrane-bound proteins and charged lipids are separated based on their charge-to-size ratio by electrophoretic-electroosmotic focusing (EEF) method on supported lipid bilayers (SLBs). EEF uses opposing electrophoretic and electroosmotic forces to focus and separate proteins and lipids into narrow …

    tamu Repository record for Protein Separation and Label-Free Detection on Supported Lipid Bilayers (opens in a new tab)

  5. Genetically engineered charge modifications to enhance protein separation in aqueous two-phase systems

    … engineered charge modifications on the separation behavior of proteins in aqueous two-phase extraction. The proteins used in this study included: [beta]-galactosidase, modified by the fusion of positively--or negatively--charged peptide tails to the carboxy terminus of the enzyme, and …

    iastate Repository record for Genetically engineered charge modifications to enhance protein separation in aqueous two-phase systems (opens in a new tab)

  6. Protein separation in ion-exchange membrane partitioned free -flow isoelectric focusing (IEM-FFIEF) system

    … Isoelectric Focusing (IEM-FFIEF) is an emerging separation process combining both membrane technologies and electrophoresis technologies in a series of separated chambers. Driven by electric field, IEM-FFIEF allows charged species freely migrate in bulk solutions, selectively cross the membranes …

    nus Repository record for Protein separation in ion-exchange membrane partitioned free -flow isoelectric focusing (IEM-FFIEF) system (opens in a new tab) Download file for Protein separation in ion-exchange membrane partitioned free -flow isoelectric focusing (IEM-FFIEF) system (opens in a new tab)

  7. Monolithic and perfusive packings: A study of surface chemistry and mass transfer in protein separation

    Both the monolithic and perfusive chromatographic media have bimodal pore size distribution which contributes to higher column throughput and higher column efficiencies compared to conventional particulate stationary phases. In this research, a systematic comparative study on these two types of …

    nus Repository record for Monolithic and perfusive packings: A study of surface chemistry and mass transfer in protein separation (opens in a new tab) Download file for Monolithic and perfusive packings: A study of surface chemistry and mass transfer in protein separation (opens in a new tab)

  8. Proteomics-based, multivariate, random forest method for prediction of protein separation behavior during downstream purification

    … in part because of a lack of knowledge of the separation behavior of the host cell proteins (HCP), which are the most problematic class of impurity to remove due to similarities in separation behavior with the target. The process of selecting the DSP method(s) as well as the host cell can …

    iastate Repository record for Proteomics-based, multivariate, random forest method for prediction of protein separation behavior during downstream purification (opens in a new tab)

  9. An experimental study of comparison between pH-parametric pumping and pH-cycling zone adsorption process on protein separation

    … and the pH-cycling zone adsorption process on protein separation.</p> <p>The model system studied was hemoglobin-water. on CM-Sepharose CL-6B (cation) exchanger in a single-column system. Various modes of operation were tried on both the pH-parametric pumping and the pH-cycling zone adsorption …

    njit Repository record for An experimental study of comparison between pH-parametric pumping and pH-cycling zone adsorption process on protein separation (opens in a new tab)

  10. Development of a Novel Capillary Based pH Gradient Elution Moving Boundary Electrophoresis Method and Electrolysis Free Device for Protein Separation and Concentration

    Proteins are the raw material input required for a number of biomedical purposes. In order to keep pace with the exponential demand for protein consumption from research institutions and biopharmaceutical companies, new developments in methods to isolate and collect proteins will be necessary. On …

    waterloo Repository record for Development of a Novel Capillary Based pH Gradient Elution Moving Boundary Electrophoresis Method and Electrolysis Free Device for Protein Separation and Concentration (opens in a new tab)

  11. Surface Modifications of Capillary-Channeled Polymer (C-CP) Fiber Stationary Phases for Protein Separations

    … most important and commonly used techniques for protein separation and purification. Stationary phase is the most important component of HPLC since it is where the separation takes place. Traditional HPLC columns that are packed with highly porous micro-particular silica beads suffered from …

    clemson Repository record for Surface Modifications of Capillary-Channeled Polymer (C-CP) Fiber Stationary Phases for Protein Separations (opens in a new tab)

  12. Microfluidic Processes for Protein Separations

    Microfluidic continuous-flow separation techniques offer advantages to conventional batch-based methods. In this thesis, microfluidic continuous magnetophoretic protein separation and aqueous two-phase microdroplets for protein partitioning are explored. For microfluidic continuous magnetophoretic …

    nus Repository record for Microfluidic Processes for Protein Separations (opens in a new tab) Download file for Microfluidic Processes for Protein Separations (opens in a new tab)

  13. Nano kolonėlių pakavimo optimizavimas ir taikymas sveikiems baltymams atskirti /

    … Nano Column Packing and Application for Intact Protein Separation.

    vilnius Repository record for Nano kolonėlių pakavimo optimizavimas ir taikymas sveikiems baltymams atskirti / (opens in a new tab)

  14. Hydrocyclone fractionation of chickpea flour and measurement of physical and functional properties of flour and starch and protein fractions

    … contains a high amount of starch and valuable protein. Many grain legumes (pulses) can be processed by pin milling and air classification with high separation efficiency. However, chickpea exhibits low separation efficiency because it has a relatively high fat content compared to other pulses. …

    sask Repository record for Hydrocyclone fractionation of chickpea flour and measurement of physical and functional properties of flour and starch and protein fractions (opens in a new tab)

  15. Design and Application of Task-Specific GUMBOS and NanoGUMBOS for Sensing and Separation

    … employs task-specific materials for sensing and protein separation applications. These materials were derived from a group of uniform materials based on organic salts (GUMBOS). GUMBOS are organic salts similar to ionic liquids, but have melting points ranging from 25 to 250 °C. As with ionic …

    lsu-thes Repository record for Design and Application of Task-Specific GUMBOS and NanoGUMBOS for Sensing and Separation (opens in a new tab)

  16. Improved Protein Characterizations using Ionic Liquids: PAGE and MALDI-MS

    Protein separation by polyacrylamide gel electrophoresis (PAGE) and identification by matrix assisted laser desorption ionization-mass spectrometry (MALDI-MS) are primary tools of protein analysis. In these techniques, surfactants are used in protein sample preparation in order to enhance the …

    lsu-thes Repository record for Improved Protein Characterizations using Ionic Liquids: PAGE and MALDI-MS (opens in a new tab)

Page 1 of 6