Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 107 for “"Proximal tibia"”.

  1. A BIOMECHANICAL AND COMPUTATIONAL INVESTIGATION OF PROXIMAL TIBIA BONE GRAFTING

    … BONE GRAFTING WITH DONOR MATERIAL FROM THE PROXIMAL TIBIA IS AN INCREASINGLY POPULAR CLINICAL OPTION. DESPITE THIS, THERE EXISTS SOME DISAGREEMENT IN THE SURGICAL TECHNIQUE USED. TRADEOFFS BETWEEN THE AMOUNT OF BONE GRAFT HARVESTED AND TIBIAL STABILITY NEED TO BE QUANTIFIED. MECHNICCAL …

    nus Repository record for A BIOMECHANICAL AND COMPUTATIONAL INVESTIGATION OF PROXIMAL TIBIA BONE GRAFTING (opens in a new tab) Download file for A BIOMECHANICAL AND COMPUTATIONAL INVESTIGATION OF PROXIMAL TIBIA BONE GRAFTING (opens in a new tab)

  2. Sexual dimorphism at the proximal tibia: a geometric morphometric analysis

    … a geometric morphometric analysis of the proximal tibia in a modern Caucasian American population was conducted using a sample of 100 male and 100 female tibiae from the William M. Bass Donated Skeletal Collection at the University of Tennessee at Knoxville. The proximal tibia's …

    bu Repository record for Sexual dimorphism at the proximal tibia: a geometric morphometric analysis (opens in a new tab)

  3. Compressive behavior of trabecular bone in the proximal tibia using a cellular solid model

    In this study, trabecular architecture is considered as a cellular solid structure, including both intact and damaged bone models. ??Intact?? bone models were constructed based on ideal versions of 25, 60 and 80-year-old specimens with varying trabecular lengths and orientations to 5%, and 10% …

    tamu Repository record for Compressive behavior of trabecular bone in the proximal tibia using a cellular solid model (opens in a new tab)

  4. Difference of the Mechanical Strength of Proximal Tibia according to Resection Distance from Joint Surface

    … out to evaluate the mechanical strength of proximal tibia according to resection distance from joint surface and to use this data for total knee arthroplasty. MATERIALS AND METHODS: 20 cases of knee computed tomography images were obtained from knee osteoarthritis patients undergoing total …

    ajou Repository record for Difference of the Mechanical Strength of Proximal Tibia according to Resection Distance from Joint Surface (opens in a new tab) Embargoed until 9999-12-31

  5. ADDRESSING PARTIAL VOLUME ARTIFACTS WITH QUANTITATIVE COMPUTED TOMOGRAPHY-BASED FINITE ELEMENT MODELING OF THE HUMAN PROXIMAL TIBIA

    … of QCT-FE predictions of stiffness at the proximal tibial subchondral surface. For Study #1, QCT-FE models of the human proximal tibia were developed by (1) separate modeling of cortical and trabecular bone (SM), and (2) continuum models (CM). QCT-FE models with SM and CM explained 76%-81% …

    sask Repository record for ADDRESSING PARTIAL VOLUME ARTIFACTS WITH QUANTITATIVE COMPUTED TOMOGRAPHY-BASED FINITE ELEMENT MODELING OF THE HUMAN PROXIMAL TIBIA (opens in a new tab)

  6. Biomechanical Testing of Salter-Harris Fractures Type I and II in the Distal Femur and Proximal Tibia

    Salter-Harris fractures of the proximal tibia and distal femur are common in pediatric patients that present to orthopedic surgeons. Salter-Harris type I fractures are characterized by breaks that extend only through the physis while Salter-Harris II fractures are the most common, accounting for …

    clemson Repository record for Biomechanical Testing of Salter-Harris Fractures Type I and II in the Distal Femur and Proximal Tibia (opens in a new tab)

  7. Ιntramedullary nailing versus plate fixation for the treatment of proximal tibia extra-articular fractures, a meta-analysis

    Εισαγωγή: Η επίπτωση των εξωαρθρικών καταγμάτων της εγγύς κνήμης είναι αρκετά συχνή στον γενικό πληθυσμό και αντιστοιχεί περίπου στο 5-11% όλων των καταγμάτων της κνήμης. Η βέλτιστη μέθοδος αντιμετώπισης αυτών των καταγμάτων παραμένει αμφιλεγόμενη και μέχρι σήμερα δεν υπάρχει ευρεία συναίνεση …

    athens Repository record for Ιntramedullary nailing versus plate fixation for the treatment of proximal tibia extra-articular fractures, a meta-analysis (opens in a new tab)

  8. Functional morphology of the hominin knee: locomotor signals in the trabecular structure of the distal femur and proximal tibia in extant and extinct hominoids

    … between the trabecular bone architecture of the proximal tibia in these primates. Furthermore, the third aim is to infer locomotor activities of certain extinct hominins based on their trabecular bone patterns. To achieve this, we analysed the trabecular structure of the distal femur in …

    kent Download PDF for Functional morphology of the hominin knee: locomotor signals in the trabecular structure of the distal femur and proximal tibia in extant and extinct hominoids (opens in a new tab)

  9. Validation of Subject Specific Computed Tomography-based Finite Element Models of the Human Proximal Tibia using Full-field Experimental Displacement Measurements from Digital Volume Correlation

    … strains/stiffness from QCT-FE models of the proximal tibia have been validated against experiment, yet it is unclear whether these models accurately predict internal bone mechanics (displacement). Digital volume correlation (DVC) can measure internal bone displacements and has been used to …

    sask Repository record for Validation of Subject Specific Computed Tomography-based Finite Element Models of the Human Proximal Tibia using Full-field Experimental Displacement Measurements from Digital Volume Correlation (opens in a new tab)

  10. Characterising spinal cord injury-induced osteoporosis in a rat model using micro computed-tomography and histology

    … in the trabecular bone-rich distal femur and proximal tibia during movements such as falls and transferring from bed to wheelchair. The occurrence of these fractures increases with time post-injury. Complications arising from these fractures decrease quality of life and increase morbidity and …

    strathclyde Repository record for Characterising spinal cord injury-induced osteoporosis in a rat model using micro computed-tomography and histology (opens in a new tab)

  11. Aging at the Bone-Cartilage Interface: A multimodal investigation of age-related changes in microstructural, material, and mechanical properties, and functional porosity in the mineralized cartilage and underlying bone of the proximal tibia

    … changes occurring at long bone extremities. The proximal tibia of adult and aged rats serves as a biological model, allowing isolation of aging effects in a mechanically demanding region frequently affected by osteoarthritis. Micro-computed tomography revealed subchondral plate thickening and …

    liege Repository record for Aging at the Bone-Cartilage Interface: A multimodal investigation of age-related changes in microstructural, material, and mechanical properties, and functional porosity in the mineralized cartilage and underlying bone of the proximal tibia (opens in a new tab)

  12. The role of surgery in early osteoarthritis of the knee

    … progression was driven by the alignment of the proximal tibia. Using semi-quantitive MRI analysis it was found that the increased structural progression seen in subjects with proximal tibia vara, was due to more full thickness cartilage loss in the central medial tibia. These are novel …

    oxford Repository record for The role of surgery in early osteoarthritis of the knee (opens in a new tab)

  13. Stiffness of the Proximal Tibial Bone in Normal and Osteoarthritic Conditions: A Parametric Finite Element Simulation Study

    … a parametric finite element (FE) model of the proximal tibia, the primary objective of this study was to determine the relative and combined effects of OA-related osteophyte formation, and morphological and mechanical alterations to subchondral and epiphyseal bone on overall bone stiffness. The …

    sask Repository record for Stiffness of the Proximal Tibial Bone in Normal and Osteoarthritic Conditions: A Parametric Finite Element Simulation Study (opens in a new tab)

  14. Precision analysis of site-specific dual-energy x-ray absorptiometry in persons with spinal cord injury and persons who are able-bodied

    … four DXA scans at sites of the distal femur, proximal tibia, and calcaneus were completed in 10 persons who are able-bodied and 10 persons with chronic SCI. Using forearm sub region analysis, we measured the BMD and calculated the precision error for a total of 7 ROI at these sites. Despite a …

    manitoba Repository record for Precision analysis of site-specific dual-energy x-ray absorptiometry in persons with spinal cord injury and persons who are able-bodied (opens in a new tab)

  15. Impact of Omega-3 Polyunsaturated Fatty Acids on Bone Adaptations to Simulated Resistance Training

    … Structural and densitometric properties of proximal tibia were measured using in vivo peripheral quantitative CT. Bone formation rate was quantified on the periosteal the surface by standard bone histomorphometry after intraperitoneal injections of calcein. There was a significant main …

    tamu Repository record for Impact of Omega-3 Polyunsaturated Fatty Acids on Bone Adaptations to Simulated Resistance Training (opens in a new tab)

  16. An analysis of sexual dimorphism using geometric morphometrics of the femur and tibia: the use of GM in assessing sex of fragmented remains

    … analyzes the sexual dimorphism of the femur and tibia using geometric morphometrics. The study sample includes 250 individuals of known sex and age at death with complete, non-damaged, non-pathological skeletal remains from the William M. Bass Donated Skeletal Collection at the University of …

    bu Repository record for An analysis of sexual dimorphism using geometric morphometrics of the femur and tibia: the use of GM in assessing sex of fragmented remains (opens in a new tab)

  17. Correlating mechanical properties of cancellous bone in the rat with various density measures

    … (RPC) testing of the cancellous bone of the proximal tibia. The objective of this study was to improve the current testing methods with an emphasis on the location of the RPC specimens, and to correlate the mechanical properties of the rodent cancellous bone with the various density measures. …

    tamu Repository record for Correlating mechanical properties of cancellous bone in the rat with various density measures (opens in a new tab)

Page 1 of 6