Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 5 of 5 for “"Pull-off testing"”.

  1. Methods to Improve Bond on FRP Wrapped Piles

    … These methods are compared using 3 types of testing, both nondestructive and otherwise: acoustic analysis, infrared thermography, and pull-off testing. Therefore not only FRP bond improvement techniques are compared but also the techniques for bond evaluation. Findings have shown a definite …

    usf Repository record for Methods to Improve Bond on FRP Wrapped Piles (opens in a new tab)

  2. Feasibility of Epoxy Bond Enhancement on High-Strength Concrete

    … active pulse thermography, and tensile pull-off testing was performed. Results indicate that lower-viscosity epoxies and vacuum exposure does not increase bond strength, and surface preparation by wet jetting may improve bond quality as compared to preparation by sand blasting, however …

    usf Repository record for Feasibility of Epoxy Bond Enhancement on High-Strength Concrete (opens in a new tab)

  3. Evaluating CFRP-Masonry Bond Using Thermal Imaging

    This study presents results from non-destructive testing to evaluate the degradation of the CFRP-masonry bond using thermal imaging. The goal of the research was to identify locations where there was evidence of bond deterioration that could subsequently be verified through destructive pull-off …

    usf Repository record for Evaluating CFRP-Masonry Bond Using Thermal Imaging (opens in a new tab)

  4. Performance evaluations of latex-modified and silica fume modified concrete overlays for bridge decks

    … on one slab and SFMC overlay on the other. Pull-Off testing was conducted at different ages for assessing the bond performance of the overlays. The differential length change and differential temperature developed at the interface were continuously monitored using concrete embedment gages …

    wvu Repository record for Performance evaluations of latex-modified and silica fume modified concrete overlays for bridge decks (opens in a new tab)

  5. Advancing Performance-Based Design for Concrete Bridge Overlays: A Field-Scale Evaluation

    … was evaluated at three months using ASTM C1583 pull-off testing. Substrate carbonation depth was measured before overlay placement using the phenolphthalein indicator method. Early-age strain development was monitored continuously for 28 days using Geokon Model 4200 vibrating-wire strain gauges …

    texas-state Repository record for Advancing Performance-Based Design for Concrete Bridge Overlays: A Field-Scale Evaluation (opens in a new tab)