Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 81 for “"Pullout Test"”
-
Finite element simulation of single fiber pullout test
… 2 FEA models used to analyze the Single Fiber Pullout case. Since both the FBC ( Fixed Back Configuration) and the RTC ( Restrained Top Configuration ) cases were studied, two FEA models were developed, one for each test configuration. Two material sets: one with a high modulus matrix Em/Ef = …
-
Finite Element and Pullout Test Performance of Welded Wire Mats
This paper reports on the pullout test performance of welded-wire reinforcing mats. A 126-foot high mechanically stabilized earth wall was constructed at Kennecott Utah Copper. In the lower half of the wall, single lengths of 50-foot long welded-wire mats were used. In the top half of the wall, two …
-
Development of a pullout test method for adhesive applied roofing systems
… Roofing Systems (AARS). It was determined that a pullout test method -- a test in which the adhered components of roofing samples were subjected to tensile loading until failure -- could be used to quantify wind uplift performance. From the literature study, critical variables were extracted. …
-
Bond stress distribution in concrete beams and eccentric pullout specimens
… was used with minor alterations. An eccentric pullout specimen was used as the basic specimen for this investigation. A study of the correlation between the stress distribution in the pullout specimen and the stress distribution measured from a crack in a reinforced concrete beam was one of the …
-
Field performance of geosynthetics reinforced soil slope with residual soil
… residual soil is evaluated.Laboratory and field pullout test were conducted and the short and long term performance of a geosynthetics reinforced soil slope is monitored.
-
Estudo da aderência bambu-bioconcreto
… characterized by direct tensile and flexural tests and the bioconcretes were produced containing 25, 35 and 45% volumetric fractions of bamboo bioaggregates. Bioconcretes were mechanically characterized by direct tensile, uniaxial compression and diametral compression tensile tests. In order …
-
Monotonic and cyclic pullout resistance of geosynthetics
… repeated non-dynamic or cyclic, and dynamic. The test method best suited to model the anchorage behaviour is the pullout test. A large scale pullout apparatus was designed that accommodates a soil sample 1.30 m long x 0.64 m wide x 0.60 m thick. Samples of a uniformly-graded medium sand were …
-
A Comparison of the Bond Strength of Spun and Static Cast Concrete Specimens
The purpose of this study is to determine the pullout bond strength of seven wire steel strand in two types of concrete: spun and static cast. It is perceived that the spinning process used in the manufacturing of concrete poles introduces compaction forces that densifies the concrete and hence, …
-
Experimental and numerical investigations of axial pullout behavior of buried ductile iron pipe
… thesis presents the design of a new laboratory test facility developed for pullout testing of buried pipelines that investigate the behavior of pipelines subjected to axial ground movements. The test facility is first assessed using finite-element modelling to identify the effects of the size of …
-
Estudo do ensaio de destacamento (Pullout) para fibras vegetais inseridas em compósitos cimentícios
… of plant fibers in cementitious matrices is the pullout test. This test allows testing the effectiveness of the bond between the fiber and the matrix, as well as determining the critical length of the fiber, a crucial factor for evaluating the transmission of forces in the material when subjected …
-
Stress transfer between FRP reinforcement and concrete
… issues have been investigated. Firstly, a novel pullout test was developed to investigate the stress transfer mechanics and failure modes of near surface mounted (NSM) FRP strengthened RC blocks at a fundamental level. Secondly, the (FEA) was used to gain a detailed understanding of stress …
-
Numerical modeling and analysis of pullout tests of sheet and geogrid inclusions in sand
… studying the soil-inclusion interaction in the pullout test is by numerical modeling. Several of the numerical studies available in the literature lack the integration of consistent material characterization as input for the numerical model, resulting in little phenomenological description of …
-
A Relationship Between the Strengths of Type N Cubic Mortar Specimens and In-Situ Mortar
… determined using the American Societyfor Testing and Materials (ASTM) standard method using 2 inch cubes which are compressed tillfailure. There is however a disparity between the compressive strengths of mortar cubes, and insitumortar. This disparity is a result of the differences in …
-
Un-tensioned pullout tests to predict the bond quality of different prestressing reinforcements used in concrete railroad ties
An experimental testing program was conducted at Kansas State University (KSU) to test the bond characteristics of various 5.32-mm-diameter steel wires and smaller diameter (less than 0.5 in.) strands used in prestressed concrete railroad ties. A total of 13 wires and six strands produced by seven …
-
Avaliação do sistema de aderência entre argamassas colantes no assentamento de piso sobre piso
… were also objects of this study. Throught the pullout test, it was found that none of the three mortars reached the resistance recommended by 0,3 MPa, following NBR 13.753 – External or internal floor covering with ceramic plates and using adhesive mortar (ABNT, 1996). With the realization of …
-
Characterization of Interfacial Bond Strength in Fiber Reinforced Cementitious Composites by a Modified Pullout Method
… reinforced cementitious composites. A modified pullout test has been designed to determine the interfacial bond parameters for natural fibers with cementitious system, and were repeated for artificial fibers for comparison studies. Steel, polypropylene, and wheat straw fibers were tested with …
-
Long-term pullout resistance of geogrid reinforcement for retaining walls
… of unsaturated and saturated condition. Eight pullout test boxes were designed and constructed, each with a specially designed stainless steel clamp. The measured strain-time relations for unsaturated and saturated soils for various levels of the pullout force until the peak value (up to 10,000 …
-
Bond Behavior of Fiber Reinforced Polymer Bars Under Hinged Beam Conditions
… weight concrete (NWC) hinged beam-end specimens, tested in accordance with two laboratory conditions. Reinforcing bars of different diameter, material configuration, and finished surface preparation were tested for bond strength parameters determined in accordance with ACI Committee Report 440.3. …
-
A Study of Correlations between Rock Bolt Pull-Out Tests and Rock Mass Rating Scores in Underground Mining
Rock bolt pullout testing is a common method of testing the strength of ground support in underground mining over time. Bolts that fail the pullout test fail either due to shear failure at the head of the bolt or by slipping in one piece out of structurally incompetent rock. There are many methods …
-
Soil-geosynthetics interaction in geosynthetics reinforced soil wall
… few years at NUS was concentrating on laboratory pullout tests and on the investigation of the drainage capability of geotextile. Only limited numbers of field pullout test on geotextile was conducted at Bukit Panjang, Singapore. Present research focus on the field and laboratory pullout tests in …
Page 1 of 5