Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 54 for “"Pulmonary nodules"”.
-
The segmentation of nonsolid pulmonary nodules in CT images
Nonsolid nodules are a common radiographical finding in high resolution CT images of the lung. A main factor in determining a nodules malignancy status is the change in the nodule size over time. A method for automatically segmenting a nonsolid nodule from CT images is presented in this thesis. …
-
Computer-Aided Detection Of Pulmonary Nodules From Ct Scans
… slices of a patient's CT scan for small pulmonary nodules that can manifest early lung cancer. However, radiologists routinely miss nodules due to fatigue and the error-prone nature of the work, which may ultimately lead to incorrect diagnostic decisions. It has been shown that detection …
-
Detection and description of pulmonary nodules through 2D and 3D clustering
… detection, description and classification of pulmonary nodules offer the potential for early diagnosis of cancer and greater efficiency in the reading of computerised tomography (CT) images. CT scan centres are currently experiencing high loads and experts shortage, especially in developing …
-
Automatic detection and characterization of pulmonary nodules in thoracic CT scans
… Early stage lung cancer manifests itself as pulmonary nodules, which are described as round opacities, well or poorly defined, measuring up to 3 cm in diameter. Thin-slice helical chest CT scans have a sub-millimeter resolution at which small pulmonary nodules can be detected. Computer-aided …
-
Artificial intelligence for cancer imaging: Integrated frameworks for hepatocellular carcinoma and pulmonary nodules.
… (HCC) on multiphase CT/MRI and indeterminate pulmonary nodules on thin-slice CT—while articulating evaluation and reporting practices that support credible clinical translation. The work proceeds in six core chapters. Two focused reviews synthesize the state of the art in (i) radiomics/AI for …
-
Malignancy risk estimation of screen-detected pulmonary nodules: validation of current management recommendations
Radboud University, 09 december 2020
-
Towards safe implementation of AI-based malignancy probability estimation of pulmonary nodules on thoracic CT
Contains fulltext : 335247.pdf (Publisher’s version ) (Closed access)
-
Image-guided video-assisted thoracoscopic surgery (VATS) excision of small peripheral pulmonary nodules (SPPN) in patients with previous extra-thoracic malignancies
… end coiled on the visceral pleural surface. Nodules were removed by VATS wedge excision using endostapler with visualization by intraoperative fluoroscopy and VATS. Results: A total of 50 patients with a cumulative history of 14 different extra-thoracic cancers (57% female, mean age 62 years) …
-
Geographic variations in chest-CT scan lung cancer diagnosis from environmental exposures
… detect small suspicious non-urgent indeterminate pulmonary nodules. The goals of managing suspicious non-urgent indeterminate pulmonary nodules are early cancer detection, avoidance of unnecessary procedures for benign nodules, and efficient economic use of resources in distinguishing between …
-
Comparative evaluation of guided shape-sensing robotic bronchoscopy vs. electromagnetic navigation with cone-beam computed tomography for pulmonary nodule diagnosis
… have significantly improved the diagnosis of pulmonary nodules, with navigational bronchoscopy systems like electromagnetic navigation bronchoscopy (ENB) and shape-sensing robotic-assisted bronchoscopy (ssRAB) offering enhanced precision and safety. Cone-beam computed tomography (CBCT) has …
-
Convolutional Neural Network based Malignancy Detection of Pulmonary Nodule on Computer Tomography
… the lung cancer due to the high sensitivity of pulmonary nodule detection. However, distinguishing pulmonary nodule in-between malignant and benign is still not an easy task. As the CT scans are mostly in relatively low resolution, it is not easy for radiologists to read the details of the scan …
-
Risk Stratification for Lung Cancer Screening using an Epidemiologic, Molecular, and Quantitative Imaging Approach
… management of indeterminate screen-detected pulmonary nodules remains an important barrier to optimal screening program efficiency. The lung function analysis in Manuscript 1 identifies important lifecourse exposures that shape the trajectory of pulmonary health for never-smokers and advances …
-
A microreactor approach for chemoselective capture and analysis of carbonyl compounds in air and exhaled breath.
… lung cancer (LC) patients, patients with benign pulmonary nodules and healthy volunteers (smokers and non-smokers) were collected and analyzed using the same method. The FTICR-MS spectra showed that the exhaled breath samples from LC patients have a unique pattern of VOCs, in comparison with …
-
LCD-OpenPACS: sistema integrado de telerradiologia com auxílio ao diagnóstico de nódulos pulmonares em exames de tomografia computadorizada
… difficult. This leads to omission of nodules by human radiologist. This thesis presents a development of a computer-aided diagnosis system (CADe) tool for the detection of lung nodules in Computed Tomography study. The system, called LCD-OpenPACS (Lung Cancer Detection - OpenPACS) …
-
Development and application in clinical practice of Computer-aided Diagnosis systems for the early detection of lung cancer
… chest radiography. However, the detection of pulmonary nodules in low-dose chest CT scans is a very difficult task for radiologists, because of the large number (300/500) of slices to be analyzed. In order to support radiologists, researchers have developed Computer aided Detection (CAD) …
-
Characterization of microreactor and analysis of carbonyl compounds in exhaled breath.
… serve as biomarkers to distinguish patients with pulmonary nodules from healthy controls. The analysis of exhaled breath samples of the lung cancer (LC) patients, patients with benign pulmonary nodules and healthy controls led to three VOCs (2-butanone, 3-hydroxy-2-butanone and 4-hydroxy-2-nonenal …
Page 1 of 3