Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 90 for “"Pulse Oximeter"”.

  1. PDA based ambulatory pulse oximeter

    … aim of the research was to develop an ambulatory pulse oximeter which can be used to monitor the SpO_2 heart rate (HR) and plethsymograph (PPG) waveform of a person. To achieve this, an algorithm was developed in LabVIEW 8.0 to extract the HR, SpO_2 and PPG data from a Nonin Xpod device, Nonin …

    njit Repository record for PDA based ambulatory pulse oximeter (opens in a new tab)

  2. Monitoring sleep and sleep breathing disorders using pulse oximeter photoplethysmogram

    … (IRR) in children using the characterization of pulse oximetry photoplethysmogram (PPG). To evaluate the algorithms, we recorded the oxygen saturation (SpO₂) and PPG signals from 160 children using a phone-based oximeter consisting of a microcontroller-based pulse oximeter module interfacing a …

    ubc Repository record for Monitoring sleep and sleep breathing disorders using pulse oximeter photoplethysmogram (opens in a new tab) Download PDF for Monitoring sleep and sleep breathing disorders using pulse oximeter photoplethysmogram (opens in a new tab)

  3. Monte Carlo investigations of the effect of skin pigmentation on pulse oximeter accuracy

    … pigmentation on the signal and its impact on pulse oximetry. While this phenomenon was first revealed in the 1980s, numerous publications since the COVID-19 pandemic have led this topic to resurface. The causes of discrepancies found in oxygen saturation measurement by pulse oximetry (SpO2), …

    city-london Download PDF for Monte Carlo investigations of the effect of skin pigmentation on pulse oximeter accuracy (opens in a new tab)

  4. The Use of Strict Pulse Oximeter Parameters and the Effects on Retinopathy of Prematurity in the Premature Neonate

    … study was to identify the effect of strict pulse oximeter parameters on the incidence and severity of ROP in premature infants. Data were collected retrospectively from chart reviews to follow pulse oximeter measurements, length of oxygen exposure, and ocular exam results in a Midwestern, …

    mo-state Repository record for The Use of Strict Pulse Oximeter Parameters and the Effects on Retinopathy of Prematurity in the Premature Neonate (opens in a new tab)

  5. Power-efficient and high-performance interference resilientpulse oximeter

    This thesis presents a novel sigma delta-based pulse oximeter with higher resilience against ambient light interference in comparison to the conventional pulse oximeters available in the market. The pulse oximeter reported in this thesis uses a novel cross-coupled sigma delta modulator to drive the …

    westminster Repository record for Power-efficient and high-performance interference resilientpulse oximeter (opens in a new tab)

  6. Pulse Oximetry: The impact of the computer engineer

    … Mattes a professor in physiology introduced the pulse oximeter whichis a non invasive device that is used for measuring oxygen saturation level and pulserate. Pulse oximeter is based on the principle that oxyhemoglobin and deoxyhe-moglobin absorb light of different wavelength differently. The …

    chalmers Repository record for Pulse Oximetry: The impact of the computer engineer (opens in a new tab)

  7. Pulse oximetry in low-income settings: a case study of Kenyan hospitals

    <p>Pulse oximeters are low-cost, easy to use, and effective at detecting hypoxemia (low blood oxygen levels), a common complication of bronchiolitis, asthma, and pneumonia, the leading infectious cause of death in children worldwide. However, pulse oximeters are often unavailable in lowincome …

    oxford Repository record for Pulse oximetry in low-income settings: a case study of Kenyan hospitals (opens in a new tab)

  8. Σύγκριση μεθόδων αιμόστασης κερκιδικής αρτηρίας μετά από ενδοστεφανιαίες επεμβάσεις με κερκιδική προσπέλαση

    … remains unknown. Aims. To determinewhich method (pulse oximeter versus the traditional radial artery palpation) is better to achieve patent hemostasis.Methods.This is a prospective, single center study, which included 299 consecutive patients who underwent coronary angiography or percutaneous …

    greece Repository record for Σύγκριση μεθόδων αιμόστασης κερκιδικής αρτηρίας μετά από ενδοστεφανιαίες επεμβάσεις με κερκιδική προσπέλαση (opens in a new tab)

  9. Garment-Based Respiration And Pulse Oximetry Sensing Using A Stitched Sensor And Chest Mounted Pulse Oximetry Sensor

    … chest-mounted stitched strain sensor and pulse oximeter for the purpose of developing a garment-based sensing device. A wearable or garment-based device could be used for long term or long distance monitoring a wearer’s respiratory health when regular access to healthcare is challenging …

    umn Repository record for Garment-Based Respiration And Pulse Oximetry Sensing Using A Stitched Sensor And Chest Mounted Pulse Oximetry Sensor (opens in a new tab)

  10. Wireless Sensor Platform for Pulse Oximetry

    Pulse rate and oxygen saturation are two important clinical measurements that indicate the state of a person’s essential body functions. Oxygen saturation is the measurement of oxygenated hemoglobin in arterial blood i.e. it indicates the level of oxygen in the blood. Pulse oximeters, consisting of …

    rit Repository record for Wireless Sensor Platform for Pulse Oximetry (opens in a new tab)

  11. Trauma Detection Personal Locator Beacon System

    … (4) physiological parameters: skin conductance, pulse oximeter, user movement via Freefall and activity/inactivity and impact detection, and finally body temperature. For these four physiological parameters respective sensor circuitry was designed and data from these sensors read and analyzed by …

    usf Repository record for Trauma Detection Personal Locator Beacon System (opens in a new tab)

  12. Heart Rate Artifact Suppression

    … corrupts heart rate measurements in current pulse oximetry systems. In many, almost any motion will greatly diminish the system’s ability to extract a reliable heart rate. The artifact is most likely present due to normally non-pulsatile components of the body, such as venous blood and tissue …

    gvsu Repository record for Heart Rate Artifact Suppression (opens in a new tab)

  13. Arterial Oxygen Saturation as a Predictor of Acute Mountain Sickness and Summit Success among Mountianeers

    … saturation (SaO2), as measured by a finger pulse oximeter upon rapid arrival to 4260 m, could be predictive of acute mountain sickness (AMS) or summit success on a climb to 5640 m. In total 73 climbers volunteered to participate in the study. After excluding those taking drugs to counteract …

    utahstate Repository record for Arterial Oxygen Saturation as a Predictor of Acute Mountain Sickness and Summit Success among Mountianeers (opens in a new tab)

  14. The development of biomedical instrumentation using backscattered laser light

    … the techniques of laser Doppler flowmetry and pulse oximetry. An investigation of the responses of Doppler flowmeters using different signal processing bandwidths and laser sources revealed two major findings. Firstly, that careful choice of processing bandwidth is required in order to sample …

    oxford-brookes Repository record for The development of biomedical instrumentation using backscattered laser light (opens in a new tab) Download PDF for The development of biomedical instrumentation using backscattered laser light (opens in a new tab)

  15. In vivo investigations of photoplethysmograms and arterial oxygen saturation from the auditory canal in conditions of compromised peripheral perfusion

    Pulse oximeters rely on the technique of photoplethysmography (PPG) to estimate arterial oxygen saturation (SpO2). In conditions of poor peripheral perfusion such as hypotension, hypothermia, and vasoconstriction, the PPG signals detected are often small and noisy, or in some cases unobtainable. …

    city-london Download PDF for In vivo investigations of photoplethysmograms and arterial oxygen saturation from the auditory canal in conditions of compromised peripheral perfusion (opens in a new tab)

  16. Investigation of fontanelle photoplethysmographs and oxygen saturations in intensive care neonates and infants utilising miniature photometric sensors

    … determined non-invasively by a device called a pulse oximeter. Sensors are usually placed on a hand or foot where their operation relies on the presence of pulsatile arterial blood. Light shines at two or more wavelengths (usually red and infrared) into the tissue where the pulsatile blood …

    city-london Download PDF for Investigation of fontanelle photoplethysmographs and oxygen saturations in intensive care neonates and infants utilising miniature photometric sensors (opens in a new tab)

  17. HRVCam: Measuring Heart Rate Variability With A Camera

    … measured using contact devices such as a pulse oximeter. However, recent research in the eld of non-contact imaging Photoplethysmography (IPPG) has made it possible to extract vital sign measurements from the video recording of any exposed skin surface, such as a person's face. Extracting …

    rice Repository record for HRVCam: Measuring Heart Rate Variability With A Camera (opens in a new tab)

  18. Depression and hypoxia in post myocardial infarction patients

    … was used to measure depression and the Nellcor Pulse Oximeter was used to measure hypoxia. Data obtained from the two instruments were statistically analyzed using the Pearson product-moment correlation technique. Results of the study demonstrated a significant relationship between depression …

    twu Repository record for Depression and hypoxia in post myocardial infarction patients (opens in a new tab)

Page 1 of 5