Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 126 for “"Pulse Oximeter,"”
-
PDA based ambulatory pulse oximeter
… aim of the research was to develop an ambulatory pulse oximeter which can be used to monitor the SpO_2 heart rate (HR) and plethsymograph (PPG) waveform of a person. To achieve this, an algorithm was developed in LabVIEW 8.0 to extract the HR, SpO_2 and PPG data from a Nonin Xpod device, Nonin …
-
DEVELOPMENT OF CONTINUOUS MONITORING PULSE OXIMETER DEVICE
… Wearable devices commonly use PPG based pulse oximetry to measure heart rate and oxygen saturation, two very important health metrics, although limitation in their design prevent them from being very practical from a health monitoring perspective. This research presents the design and …
-
Development of a stand-alone pulse oximeter
Hoje em dia, a instrumentação biomédica ocupa posição de destaque dentro da medicina. Seguindo essa tendência, o oxímetro de pulso tornou-se num importante instrumento para elucidar acerca do funcionamento do organismo e alertar para eventuais anomalias através da monitorização do batimento …
-
Perioperative comparison of the agreement between a portable fingertip pulse oximeter vs. a conventional bedside pulse oximeter in adult patients (COMFORT trial)
Background: Low-cost, portable fingertip pulse oximeters are widely available to health professionals and the public. They are often not tested to ISO standards, or only undergo accuracy studies in healthy volunteers under ideal laboratory conditions. This study aims to pragmatically evaluate the …
-
Wireless reflectance pulse oximeter design and photoplethysmographic signal processing
Pulse oximetry, a noninvasive circulatory system monitoring technique, has been widely adopted in clinical and homecare applications for the determination of heart rate and blood oxygen saturation, where measurement locations are typically limited to fingertips and earlobes. Prior research …
-
Monitoring sleep and sleep breathing disorders using pulse oximeter photoplethysmogram
… (IRR) in children using the characterization of pulse oximetry photoplethysmogram (PPG). To evaluate the algorithms, we recorded the oxygen saturation (SpO₂) and PPG signals from 160 children using a phone-based oximeter consisting of a microcontroller-based pulse oximeter module interfacing a …
-
Mobile sleep apnea detection and monitoring based on thermocouple and pulse oximeter sensors
… in the blood is obtained with utilizing pulse oximeter. An analog electronic circuit is designed to readout thermocouple and pulse oximeter signals. According to the collected respiratory and pulse oximetry signals, sleep apnea is detected in real time by a software implemented into an …
-
Monte Carlo investigations of the effect of skin pigmentation on pulse oximeter accuracy
… pigmentation on the signal and its impact on pulse oximetry. While this phenomenon was first revealed in the 1980s, numerous publications since the COVID-19 pandemic have led this topic to resurface. The causes of discrepancies found in oxygen saturation measurement by pulse oximetry (SpO2), …
-
The Use of Strict Pulse Oximeter Parameters and the Effects on Retinopathy of Prematurity in the Premature Neonate
… study was to identify the effect of strict pulse oximeter parameters on the incidence and severity of ROP in premature infants. Data were collected retrospectively from chart reviews to follow pulse oximeter measurements, length of oxygen exposure, and ocular exam results in a Midwestern, …
-
Power-efficient and high-performance interference resilientpulse oximeter
This thesis presents a novel sigma delta-based pulse oximeter with higher resilience against ambient light interference in comparison to the conventional pulse oximeters available in the market. The pulse oximeter reported in this thesis uses a novel cross-coupled sigma delta modulator to drive the …
-
The Design and Development of a New Patented Semi-Disposable Pulse Oximeter Sensor Utilizing a Flexible PVC Material and a Propietary Overmolding Process
… prototypes, and manufacturing a new innovative pulse oximeter sensor. In-depth research will illustrate the historical significance and progress over the past few years of pulse oximetry and the associated sensors. The fundamental objective of this thesis center around the goal of developing a …
-
Pulse Oximetry: The impact of the computer engineer
… Mattes a professor in physiology introduced the pulse oximeter whichis a non invasive device that is used for measuring oxygen saturation level and pulserate. Pulse oximeter is based on the principle that oxyhemoglobin and deoxyhe-moglobin absorb light of different wavelength differently. The …
-
Pulse oximetry in low-income settings: a case study of Kenyan hospitals
<p>Pulse oximeters are low-cost, easy to use, and effective at detecting hypoxemia (low blood oxygen levels), a common complication of bronchiolitis, asthma, and pneumonia, the leading infectious cause of death in children worldwide. However, pulse oximeters are often unavailable in lowincome …
-
A Special Inference Problem in Repeated Measures Design with Applications to Pulse Oximetry
The objective of pulse oximetry studies is to demonstrate that the paired repeated measurements from a pulse oximeter (SpO<sub>2</sub>) and a co-oximeter (SaO<sub>2</sub>), agree sufficiently with respect to a pre-specified agreement score. The measure of agreement in pulse oximetry studies is the …
-
Σύγκριση μεθόδων αιμόστασης κερκιδικής αρτηρίας μετά από ενδοστεφανιαίες επεμβάσεις με κερκιδική προσπέλαση
… remains unknown. Aims. To determinewhich method (pulse oximeter versus the traditional radial artery palpation) is better to achieve patent hemostasis.Methods.This is a prospective, single center study, which included 299 consecutive patients who underwent coronary angiography or percutaneous …
-
The utility of occlusion of the pulse oximeter trace in the estimation of systolic blood pressure during spinal anaesthesia for caesarean section: the effect of body mass index
… blood pressure (SBP) by disappearance of the pulse oximeter trace (DOT), with noninvasive blood pressure (NIBP) measurement, across the range of body mass index (BMI), during spinal anaesthesia (SA) for caesarean section (CS). Methods: Three groups of 25 parturients were recruited, with BMI of …
-
Photoplethysmographic signal analysis using systolic and diastolic peaks
Pulse Oximeter (PO) is a non-invasive device, used for measuring Oxygen saturation (SpO2), which refers to the concentration of oxygen in blood. Clinically, Pulse Oximeter is used to measure and display both SpO2 and Heart rate, most useful in Intensive Care Units. In this dissertation, a …
-
Wireless Biomedical Sensor Network Reference Design Based on the Intel® Edison Platform
… computer includes an electrocardiograph, a pulse oximeter, and an accelerometer/gyrometer. All sensors are based on the same physical footprint and connector placement so that the sensors can be stacked to create a collection with a minimal volume and footprint. The latest hardware version …
Page 1 of 7