Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 16 of 16 for “"Pulse duplicator"”.
-
Characterization of pulse duplicator model for testing of heart valves
<p>The design and development of a pulse duplicator system for testing of prosthetic valves is described. The performance characteristics were evaluated by computing the input impedance of the system from the measured pressure and flow signals for different simulation configurations. The study has …
-
An intelligent computerized pulse-duplicator for the in-vitro evaluation of prosthetic heart valves
<p>A computerized data acquisition system is presented for the in-vitro determination of the hydrodynamic performance of prosthetic heart valves. High speed data acquisition and ensemble averaging techniques are employed to minimize error and provide a standard for data collection and analysis …
-
In vitro testing and evaluation of intraaortic and extraaortic balloon counterpulsation devices
… by modifying a mechanical heart simulator -- the pulse duplicator system -- to accommodate both devices, and developing a software system that could collect and process the data relevant to the operation of the two balloons. Both counterpulsation techniques were tested in the pulse duplicator …
-
Towards a tri-leaflet polyurethane heart valve prothesis
… comprising a hydrodynamic function tester (pulse duplicator) and accelerated fatigue testers, have been upgraded. An improved data acquisition system combined with a computerised control system has been developed for the pulse duplicator. The new system allows valve function to be more …
-
In vitro comparative hydrodynamic study of heart valve bioprostheses under accelerated fatigue conditions and under physiological conditions
… of an accelerated fatigue testing system*, and a pulse duplicator (heart simulator)*, to evaluate the hydrodynamic characteristics of cardiac bioprostheses.</p><p>The hydrodynamic performance of these prosthetic valves is compared when tested using each machine, in order to assess the determining …
-
In situ aortic root in vitro testing of the stented and stenless porcine aortic heart valves
… is connected to a holder then inserted in the Pulse Duplicator System. This aortic root is kept fresh with antiseptic solutions but not fixed with glutaraldehyde since it can become stiffer than the natural aorta. Method - In vitro hemodynamics, blood flow performance, of porcine bioprostheses …
-
Aortic Valve Analysis and Area Prediction using Bayesian Modeling
… compared to fresh valves using a programmable pulse duplicator that could simulate physiological conditions. Hydraulic conditions in the pulse duplicator were modified by varying mean flow rate and mean arterial pressure. Pressure drops across the aortic valve, flow rate and back pressure (mean …
-
Fully Coupled Fluid Structure Interaction Simulation of Bioprosthetic Heart Valves: A Numerical and Experimental Analysis
… blood flow passing through the valve inside a pulse duplicator system. This project is a major step towards the experimental validation of FSI modeling for analyzing tissue heart valves.</p>
-
In vitro fluid dynamics of the Bjork-Shiley monostrust mitral disc valve using laser doppler anemometry
… mitral location, using a sophisticated cardiac pulse duplicator in conjunction with a 3-beam, two-component, LDA system. Time histories of the velocity profile, turbulence intensity, Reynolds stress, etc., are presented for both posterior and anterior orientations of the valve, for five …
-
Recapitulating Native Tissue Biaxial Mechanical Properties in Tissue-Engineered Pulmonary Valves to Improve Their Hemodynamic Function and Tissue Homeostasis
… valves underwent hemodynamic evaluation in a pulse duplicator and their hemodynamic behaviour and tissue remodelling were investigated. Pulmonary valves with native radial mechanics showed higher diastolic and lower systolic transvalvular pressures compared to valves with stiff radial …
-
Structural and Hemodynamic Analysis of Transcatheter Aortic Valves
… both super-annular and intra-annular designs in pulse duplicator models. The result proves that the thrombosis is likely to initiate at the fixed edge of the intra-annular design and lower belly region of the supra-annular design. Most of the blood within the neo-sinus region in the supra-annular …
-
Experimental studies of flow through deformable silicone and tissue engineered valves.
… engineered valve equivalents in a cardiovascular pulse duplicator and assess their potential for clinical use as valve replacement prostheses. A second objective was to conduct experiments under different flow conditions with synthetic silicone polymer valves of various geometries and materials …
-
Hydrodynamic performance of mechanical prosthetic heart valve
… tunnel; (ii) the steady flow in the cardiac pulse duplicator; and (iii) the pulsatile flow cardiac simulator; are presented and discussed. The significant contribution of the project lies in the fundamental data on pressure drop and its partial recovery; velocity profile, turbulence …
-
Development of a Tubular Biological Tissue-Engineered Heart Valve with Growth Potential
This thesis investigates tissue-engineered cardiovascular devices for pediatric patients and their function and growth potential in preclinical testing. Specifically, engineered tissue tubes were fabricated by entrapping dermal fibroblasts in a fibrin gel and allowing them to replace it with …
-
Innovative non-isocyanate polyurethanes for customized prosthetic heart valves
… were produced and tested in a ViVitro labs pulse duplicator, showing compliant hydrodynamic performances, comparable to bioprostheses used in clinics. Additionally, NIPU patches did not show any evidence of calcification over a period of 8 weeks, proving to be promising sustainable …