Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 9 of 9 for “"Pulse inversion"”

  1. Tissue harmonic reduction : application to ultrasound contrast harmonic imaging

    … puissante technique d’imagerie échographique (Pulse inversion) a été renforcée avec le deuxième signal pour la réduction des harmoniques. Qu’est-ce qui a été appris pendant l’investigation : le pulse inversion technique a donné une nouvelle phase codée, appelée inversion de seconde harmonique. …

    star-france Repository record for Tissue harmonic reduction : application to ultrasound contrast harmonic imaging (opens in a new tab) Restricted access

  2. Transkranielle Perfusionsmessung in Echtzeit. Evaluierung einer neuen Methode zur zerebralen Perfusionsmessung

    … zum Bildaufbau verwendet werden soll (wie bei pulse inversion und second harmonic imaging). Ein generelles Problem der Sonographie ist ihre Abhängigkeit von den Fertigkeiten des Untersuchers. ZIELE: In der vorliegenden Studie wird die Kombination aus pulse inversion harmonic imaging und …

    regensburg-diss Repository record for Transkranielle Perfusionsmessung in Echtzeit. Evaluierung einer neuen Methode zur zerebralen Perfusionsmessung (opens in a new tab)

  3. Contrast-enhanced Doppler Ultrasound Imaging using Plane Waves

    … time constraints severely limiting the number of pulses available for Doppler estimates. However, recent breakthroughs in plane-wave synthetic ultrasound considerably increased the maximal imaging frame rate, enabling new imaging trade-off previously unavailable. In this thesis, we first implement …

    toronto-retro Repository record for Contrast-enhanced Doppler Ultrasound Imaging using Plane Waves (opens in a new tab)

  4. Detection and assessment of high temperature hydrogen attack in steel pressure vessels using non-collinear wave mixing

    … wave mixing of ultrasonic waves and pulse-inversion is illustrated using a test sample extracted from a retired pressure vessel. Results show that nonlinear ultrasonics are capable of detecting and evaluating HTHA damage over the thickness of the specimen. These results are then …

    uiuc Repository record for Detection and assessment of high temperature hydrogen attack in steel pressure vessels using non-collinear wave mixing (opens in a new tab)

  5. Development and Implementation of Ultrafast Ultrasound Imaging

    … compounding plane wave imaging (CPCW) and pulse inversion (PI) with compounding angles. For removing tissue signals and detecting MBs; differential imaging (DI), PI and singular value decomposition (SVD) filtering techniques were implemented successfully. Ultrasound imaging system was …

    metu Repository record for Development and Implementation of Ultrafast Ultrasound Imaging (opens in a new tab)

  6. Focused Ultrasound-Induced Blood-Spinal Cord Barrier Opening: Methods for Clinical Translation

    … that a dual-aperture approach and a novel pulse scheme comprised of short (2-cycle) bursts with randomized phase shifts reduce the focal depth-of-field (~85% at 0.5 MHz) and mitigate the formation of standing waves. Subsequent ex vivo studies focused on the development of a novel method of …

    toronto-retro Repository record for Focused Ultrasound-Induced Blood-Spinal Cord Barrier Opening: Methods for Clinical Translation (opens in a new tab)

  7. Identifying Vulnerable Plaques with Acoustic Radiation Force Impulse Imaging

    … the hypothesis that Acoustic Radiation Force Impulse (ARFI) imaging can noninvasively identify lipid regions, that have been shown to increase a plaque's propensity to rupture, within carotid artery plaques <italic>in vivo</italic>. The work detailed herein describes development efforts and …

    duke Repository record for Identifying Vulnerable Plaques with Acoustic Radiation Force Impulse Imaging (opens in a new tab)

  8. Development of A Focused Broadband Ultrasonic Transducer for High Resolution Fundamental and Harmonic Intravascular Imaging

    … The transducers were characterized using pulse-echo techniques and exhibited broad bandwidth (110% at -6dB) with axial resolutions of <19 micron. These transducers were demonstrated to be suitable for harmonic imaging in IVUS. Improvements in lateral resolution for harmonic signals were …

    ohiolink Repository record for Development of A Focused Broadband Ultrasonic Transducer for High Resolution Fundamental and Harmonic Intravascular Imaging (opens in a new tab)

  9. Ultrafast, broadband and multi-pulse transmissions for ultrasonic imaging

    … ondes ultrasonores, en proposant une technique d'inversion d'impulsions qui utilise REC pour fournir une meilleure résolution et un meilleur rapport contraste / bruit. Ensuite, nous appliquons REC à différents schémas d’acquisition tels que les ondes divergentes et la transmission multi-lignes …

    star-france Repository record for Ultrafast, broadband and multi-pulse transmissions for ultrasonic imaging (opens in a new tab)