  1. Pulse oximetry in low-income settings: a case study of Kenyan hospitals

    <p>Pulse oximeters are low-cost, easy to use, and effective at detecting hypoxemia (low blood oxygen levels), a common complication of bronchiolitis, asthma, and pneumonia, the leading infectious cause of death in children worldwide. However, pulse oximeters are often unavailable in lowincome …

    oxford Repository record for Pulse oximetry in low-income settings: a case study of Kenyan hospitals (opens in a new tab)

  2. Investigation of the feasibility of non-invasive carbon dioxide detection using spectroscopy in the visible spectrum.

    Pulse oximeters are used in operating rooms and recovery rooms as a monitoring device for oxygen in the respiratory system of the patient. The advantage of pulse oximeters over other methods of oxygen monitoring is that they are easy to use and they are non-invasive, which means it is not necessary …

    unt Repository record for Investigation of the feasibility of non-invasive carbon dioxide detection using spectroscopy in the visible spectrum. (opens in a new tab)

  3. Real time perfusion and oxygenation monitoring in an implantable optical sensor

    … oxygen saturation can result in patient death. Pulse oximeters are standard monitoring devices which are used to obtain the perfusion level and oxygen saturation using the optical absorption properties of hemoglobin. However, in cases of varying perfusion due to hemorrhage, blood clot or acute …

    tamu Repository record for Real time perfusion and oxygenation monitoring in an implantable optical sensor (opens in a new tab)

  4. Monte Carlo Simulations to Inform Clinical Applications of Optical Devices

    … the fact that well-established devices such as pulse oximeters can exhibit subtle but dangerous inaccuracies in measurements from some darker skin pigmentation patients whose basis is not completely understood. Emerging optical technologies, such as near-infrared spectroscopy (NIRS) monitoring …

    temple Repository record for Monte Carlo Simulations to Inform Clinical Applications of Optical Devices (opens in a new tab)

  5. Use of the Masimo Rainbow Noninvasive Hemoglobin Measurement Technology for Children with Sickle Cell Disease

    PURPOSE OF STUDY: Until recently, pulse oximeters have been limited by the fact that they use two wavelengths of light to measure oxygen saturation. The use of only two wavelengths often resulted in serious errors, especially in patients with hemoglobinopathies. Although multiwavelength pulse …

    utswmed Repository record for Use of the Masimo Rainbow Noninvasive Hemoglobin Measurement Technology for Children with Sickle Cell Disease (opens in a new tab)

  6. IoT Communication Protocols in Healthcare

    … web service that can receive measurements from pulse oximeters and store them in a database. The gateway application is built using an MVC pattern, to make it easy to modify and extend, and it relies on the Antidote library to decode the ISO/IEEE 11073-20601 messages. Because the web service …

    chalmers Repository record for IoT Communication Protocols in Healthcare (opens in a new tab)

  7. Using Oximeters Heuristically: A Case for Emotionally Adaptive Pedagogy

    … diaries, clickers, cogenerative dialogues, and oximeters have been used alongside video recordings to prompt awareness of experienced emotions. When educators intentionally discuss and practice awareness, being mindfully aware of our emotions while teaching | learning, a “safe” academic space is …

    cuny-grad Repository record for Using Oximeters Heuristically: A Case for Emotionally Adaptive Pedagogy (opens in a new tab)

  8. In vivo investigations of photoplethysmograms and arterial oxygen saturation from the auditory canal in conditions of compromised peripheral perfusion

    Pulse oximeters rely on the technique of photoplethysmography (PPG) to estimate arterial oxygen saturation (SpO2). In conditions of poor peripheral perfusion such as hypotension, hypothermia, and vasoconstriction, the PPG signals detected are often small and noisy, or in some cases unobtainable. …

    city-london Download PDF for In vivo investigations of photoplethysmograms and arterial oxygen saturation from the auditory canal in conditions of compromised peripheral perfusion (opens in a new tab)

  9. Non-contact vital sign monitoring in the clinic

    … is comparable to that of the two standard pulse oximeters used in the clinical study (positioned at the finger and earlobe respectively). The mean absolute error between the heart rate estimates from the camera and the average from two reference pulse oximeters was 2.8 beats/min for over …

    oxford Repository record for Non-contact vital sign monitoring in the clinic (opens in a new tab)

  10. Optical Perfusion and Oxygenation Characterization in a Liver Phantom

    … irreversible damage to the organ or patient. Pulse oximetry is a clinically accepted method of monitoring the arterial oxygen saturation of a patient in a non-invasive manner. Pulse oximeters exploit the wavelength-dependent absorption of oxygenated and deoxygenated hemoglobin to measure a …

    tamu Repository record for Optical Perfusion and Oxygenation Characterization in a Liver Phantom (opens in a new tab)

  11. Wireless Sensor Platform for Pulse Oximetry

    Pulse rate and oxygen saturation are two important clinical measurements that indicate the state of a person’s essential body functions. Oxygen saturation is the measurement of oxygenated hemoglobin in arterial blood i.e. it indicates the level of oxygen in the blood. Pulse oximeters, consisting of …

    rit Repository record for Wireless Sensor Platform for Pulse Oximetry (opens in a new tab)

  12. PPG Heart Rate Detection in the Presence of Motion Artifacts

    … obtained by such non-invasive measurements using pulse oximeters. PPG signals, although non-invasive, come with some inherent problems. In a nonhospital environment, like when using a wearable type of sensor, a measured PPG signal predominantly suffers from motion artifacts. Ambient light …

    tamu Repository record for PPG Heart Rate Detection in the Presence of Motion Artifacts (opens in a new tab)

  13. Revealing physiological changes through colour

    … oxygen saturation was recorded using two pulse oximeters placed on the index fingers of each hand. Another study was carried out in a neonatal high-dependency unit to test the algorithms for remote vital sign monitoring in a challenging clinical setting.</p> <p>A theoretical basis for the …

    oxford Repository record for Revealing physiological changes through colour (opens in a new tab)

  14. ARRES: Computer-assisted decision support system for the post-anaesthesia care unit

    The routine use of pulse oximeters, non-invasive blood pressure monitors and electrocardiogram monitors has considerably improved patient care in the post anaesthesia period. Using an automated data collection system (ARRES), the occurrence of several adverse events frequently revealed by these …

    city-london Download PDF for ARRES: Computer-assisted decision support system for the post-anaesthesia care unit (opens in a new tab)

  15. ARRES: COMPUTER-ASSISTED DECISION SUPPORT SYSTEM FOR THE POST-ANAESTHESIA CARE UNIT

    The routine use of pulse oximeters, non-invasive blood pressure monitors and electrocardiogram monitors has considerably improved patient care in the post anaesthesia period. Using an automated data collection system (ARRES), the occurrence of several adverse events frequently revealed by these …

    greece Repository record for ARRES: COMPUTER-ASSISTED DECISION SUPPORT SYSTEM FOR THE POST-ANAESTHESIA CARE UNIT (opens in a new tab)

  16. Optimization of Wearable Devices for Heart Rate Variability Monitoring Using Strain-Gauge Plethysmography and Mechanically Accurate Tissue Mimicking Phantoms

    … as exemplified by racial biases observed in pulse oximeters. Human subjects research, however, can be prohibitively time-consuming and costly. To address this, we developed a tissue-mimicking phantom test-bed system that allows precise control of critical parameters for wearable devices. We …

    tamu Repository record for Optimization of Wearable Devices for Heart Rate Variability Monitoring Using Strain-Gauge Plethysmography and Mechanically Accurate Tissue Mimicking Phantoms (opens in a new tab) Embargoed until 2028-05-01

  17. Optimization of Wearable Devices for Heart Rate Variability Monitoring Using Strain-Gauge Plethysmography and Mechanically Accurate Tissue Mimicking Phantoms

    … as exemplified by racial biases observed in pulse oximeters. Human subjects research, however, can be prohibitively time-consuming and costly. To address this, we developed a tissue-mimicking phantom test-bed system that allows precise control of critical parameters for wearable devices. We …

    tamu Repository record for Optimization of Wearable Devices for Heart Rate Variability Monitoring Using Strain-Gauge Plethysmography and Mechanically Accurate Tissue Mimicking Phantoms (opens in a new tab) Embargoed until 2028-05-01

  18. Optimization of Wearable Devices for Heart Rate Variability Monitoring Using Strain-Gauge Plethysmography and Mechanically Accurate Tissue Mimicking Phantoms

    … as exemplified by racial biases observed in pulse oximeters. Human subjects research, however, can be prohibitively time-consuming and costly. To address this, we developed a tissue-mimicking phantom test-bed system that allows precise control of critical parameters for wearable devices. We …

    tamu Repository record for Optimization of Wearable Devices for Heart Rate Variability Monitoring Using Strain-Gauge Plethysmography and Mechanically Accurate Tissue Mimicking Phantoms (opens in a new tab) Embargoed until 2028-05-01

  19. Reconstructing Physiological Waveforms and Mapping Cerebrovascular Reactivity Directly from fMRI Using Deep Learning

    … additional equipment such as respiratory belts, pulse oximeters, and specialized end-tidal monitoring systems, the proposed method reduces cost, complexity, and participant burden. Together, these findings highlight the potential of machine learning to enhance the physiological interpretability …

    calgary Repository record for Reconstructing Physiological Waveforms and Mapping Cerebrovascular Reactivity Directly from fMRI Using Deep Learning (opens in a new tab)

  20. Eye "R" Glasses: Development of an Infrared Sensor System for Detecting the Human Body

    … of a patient’s REM sleep cycle patterns. Pulse oximeters use optical light through a process called photoplethysmography (PPG) to measure heart rate. As diverse as these all may be, this thesis attempts to prove infrared technology as a single, resourceful, and inexpensive method for …

    calpoly Repository record for Eye "R" Glasses: Development of an Infrared Sensor System for Detecting the Human Body (opens in a new tab)