Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 56 for “"Pulse--Measurement"”.

  1. High Voltage Pulse Measurement System

    … this thesis designs and constructs a low cost measurement system to safely and accurately measure high voltage, high frequency pulses in harsh EM environments. High voltage pulses apply to medical, plasma, and food industries. The difficulty of accurately measuring high voltage pulses continues …

    calpoly Repository record for High Voltage Pulse Measurement System (opens in a new tab)

  2. Pulse measurement for 17-inches KamLAND photomultiplier tube

    … we studied the several types of abnormal pulses with a Hamamatsu R7250 17" photomultiplier tube (PMT), which is being used in KamLAND detector. In prepulse measurement, by using different incident light intensities, we measured the secondary emission ratio for first dynode and the dynode …

    ut-knoxville Repository record for Pulse measurement for 17-inches KamLAND photomultiplier tube (opens in a new tab)

  3. Ultra-broadband phase-matching ultrashort-laser-pulse measurement techniques

    … for the creation and use of ultrashort pulses has progressed tremendously. Now, it is possible to generate laser pulses as short as a few femtoseconds in duration, and such pulses have been used for a wide range of applications. In addition, the means of measuring these pulses has …

    gatech Repository record for Ultra-broadband phase-matching ultrashort-laser-pulse measurement techniques (opens in a new tab)

  4. Non-contact pulse measurement for use in smart room applications.

    … for the noncontact detection of a subject's pulse. The algorithms and methodology employed in this thesis resulted in a system that was able to identify a subject's pulse with 91.2% accuracy in a partially automated system. This demonstrates the proof of concept and shows a wide new range of …

    louisville Repository record for Non-contact pulse measurement for use in smart room applications. (opens in a new tab)

  5. Troubleshooting ultrashort pulse measurement: the coherent artifact and other issues

    Theoretical limitations of several ultrashort pulse measurement techniques are investigated. Particular attention is paid to the consequences of averaging over many pulses of different shapes. Averaging over many pulses is a very common practice, and if the pulse shape varies then the measurement …

    gatech Repository record for Troubleshooting ultrashort pulse measurement: the coherent artifact and other issues (opens in a new tab)

  6. Pulse measurement of the velocity of light using a Kerr cell

    The object of this research was to develop a technique that could measure the velocity of light indirectly, with some degree of accuracy; yet could be used to demonstrate the physical fact of this velocity of light to groups of students or interested observers.

    u-pacific Repository record for Pulse measurement of the velocity of light using a Kerr cell (opens in a new tab)

  7. Development of a phase-sensitive pulse measurement technique for semiconductor mode-locked lasers

    The ultrashort pulses emitted by passive semiconductor mode-locked lasers (PSMLLs) can be applied to a wide range of applications, including modern optical communication systems, optical sampling, security, imaging or sensing. For most of these applications, it is of critical importance to gather …

    glasgow Download PDF for Development of a phase-sensitive pulse measurement technique for semiconductor mode-locked lasers (opens in a new tab)

  8. Extending ultrashort-laser-pulse measurement techniques to new dimensions, time scales, and frequencies

    … tremendous progress in the field of ultrashort-pulse measurement. However, this effort has focused mostly on the temporal behavior of 100-fs, 800-nm ultrashort pulse, ignoring other pulse lengths, wavelengths, and the very common space-time couplings or so called spatio-temporal distortions. In …

    gatech Repository record for Extending ultrashort-laser-pulse measurement techniques to new dimensions, time scales, and frequencies (opens in a new tab)

  9. From pixels to pulse: enhancing trust, quality and robustness in remote video-based pulse measurement

    … (rPPG) enables non-contact heart rate measurement using everyday cameras, offering a promising alternative to traditional contact-based methods like electrocardiography and photoplethysmography. By leveraging subtle changes in skin color and micro-movements induced by blood flow, rPPG …

    soton Download PDF for From pixels to pulse: enhancing trust, quality and robustness in remote video-based pulse measurement (opens in a new tab)

  10. Heat pulse measurement techniques for soil water flux, soil water content, and soil volumetric heat capacity

    … this research was to evaluate and improve heat pulse techniques for measuring soil water flux (Jw), soil water content (theta), and soil volumetric heat capacity (C). A new mathematical analysis was developed revealing a simple linear relationship between Jw and the natural logarithm of the …

    iastate Repository record for Heat pulse measurement techniques for soil water flux, soil water content, and soil volumetric heat capacity (opens in a new tab)

  11. Single-shot measurements of complex pulses using frequency-resolved optical gating

    … is the standard for measuring femtosecond laser pulses. It measures relatively simple pulses on a single-shot and complex pulses using multi-shot scanning and averaging. However, experience from intensity autocorrelation suggests that multi-shot measurements may suffer from a coherent artifact …

    gatech Repository record for Single-shot measurements of complex pulses using frequency-resolved optical gating (opens in a new tab)

  12. Optical-parametric-amplification applications to complex images

    … and of Optical Parametric Amplification, one for measurement and the other for imaging purposes. For measurement, we have demonstrated a robust method of measurement to simultaneously measure both optical pulses used in a pump-probe type configuration. We refer to this method of pulse measurement …

    gatech Repository record for Optical-parametric-amplification applications to complex images (opens in a new tab)

  13. COMPLETE TEMPORAL MEASUREMENT OF LOW-INTENSITY AND HIGH-FREQUENCY ULTRASHORT LASER PULSES

    … important frontiers in the field of ultrashort pulse measurement are the complete temporal measurement of low-intensity picosecond pulses in the near-infrared (NIR) and intense ultrashort pulses in the ultraviolet (UV) and extreme ultraviolet (EUV). The former are projected to find great use in …

    gatech Repository record for COMPLETE TEMPORAL MEASUREMENT OF LOW-INTENSITY AND HIGH-FREQUENCY ULTRASHORT LASER PULSES (opens in a new tab)

  14. SPINS : spectral phase interrogation using nonlinear spectra

    A novel technique for ultrafast pulse measurement is presented. This technique involves only the measurement of the fundamental, second harmonic, and third harmonic (or other third-order nonlinear) spectra of an ultrafast pulse. An algorithm is employed to generate trial SHG and THG spectra based …

    unm Repository record for SPINS : spectral phase interrogation using nonlinear spectra (opens in a new tab)

  15. Measuring broadband, ultraweak, ultrashort pulses

    … The ability to measure and manipulate ultrashort pulses hold the key to probing and understanding these key processes that physicists, engineers, chemists and biologists study today. Measuring ultrashort pulses means that we measure both the intensity (which is a function of time) and the phase of …

    gatech Repository record for Measuring broadband, ultraweak, ultrashort pulses (opens in a new tab)

  16. Characterization of thermal and hydrodynamic phonon transport using transient thermoreflectance

    … is observed with a novel method of heat pulse measurement. With thermal characterization using the TTR, four bulk materials, including glass, sapphire, GaAs, and Si are examined for interfacial thermal resistance and cross-plane thermal conductivity. Nanostructures are also tested, such …

    texas Repository record for Characterization of thermal and hydrodynamic phonon transport using transient thermoreflectance (opens in a new tab)

  17. A study of charge trapping effect on high-k device characteristics and reliability; and its implication on circuit operation

    … transient charging behavior in high-k devices, pulsed I-V measurement has been proposed. Using pulsed I-V measurement technique, the effects of interface treatment and dielectric stacks on transient characteristics of high-k transistors were studied. The results based on varying pulse frequency …

    texas Repository record for A study of charge trapping effect on high-k device characteristics and reliability; and its implication on circuit operation (opens in a new tab)

  18. Development of a wideband amplifier for use in a measurement system for the detection of prebreakdown pulses in solid dielectrics

    … needed for a system that measures prebreakdown pulses in solid dielectrics. This paper describes the development of an amplifier for this pulse measurement system. The amplifier has a voltage gain of 99 (40 dB) and a bandwidth extending from 130 Hz to 115 MHz. The small-signal rise time of the …

    ut-knoxville Repository record for Development of a wideband amplifier for use in a measurement system for the detection of prebreakdown pulses in solid dielectrics (opens in a new tab)

  19. Floating Gate Metal-Oxide-Semiconductor Based Gas Sensor

    … of water and methanol vapor. A short pulse measurement technique was introduced to measure the sensor response which was not affected by the measurement parameters.

    manitoba Repository record for Floating Gate Metal-Oxide-Semiconductor Based Gas Sensor (opens in a new tab)

Page 1 of 3