Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 224 for “"Pulse-echo"”

  1. Diagnostika betonového souvrství metodou pulse echo

    … na parkovišti pro kamiony. Využívá se metody pulse echo k zjištění delaminací whitetoppin-gu. Cílem práce je ověřit účinnost této metody a její přesnost při měření přídržnosti beto-nové vrstvy. Výsledky měření jsou porovnány s výsledky měření na zkušebním bloku. Tato studie přispívá k lepšímu …

    brno-tech Repository record for Diagnostika betonového souvrství metodou pulse echo (opens in a new tab)

  2. Pulse Echo Ultrasonic Testing of Adhesive Bonded Joints for Automotive Applications

    … to apply two variations of the Ultrasonic Pulse Echo technique namely Contact and Immersion testing for inspecting typical hem bonded automotive joints. The joints have been tested for disbond at the various metal-adhesive interfaces by using an ultrasonic scan comparison method which …

    clemson Repository record for Pulse Echo Ultrasonic Testing of Adhesive Bonded Joints for Automotive Applications (opens in a new tab)

  3. Characterisation of Planar Defects in Solids Using Ultrasonic Pulse Echo Techniques

    … between defect sizes and ranges with their echo amplitudes has been investigated both theoretically and experimentally. It is demonstrated that this relation is affected by diffraction effects which also complicate the interpretation of echo signals. These diffraction effects are interpreted …

    city-london Repository record for Characterisation of Planar Defects in Solids Using Ultrasonic Pulse Echo Techniques (opens in a new tab)

  4. Modeling of pulse-echo inspections of multi-layer panels containing delaminations

    <p>To meet the needs of counter insurgency operations the armor of tanks need to be lighter. This is accomplished by using a combination of materials: metals, composites, and ceramics. This multi-material composite armor using any combination of the above materials will need to be inspected for …

    iastate Repository record for Modeling of pulse-echo inspections of multi-layer panels containing delaminations (opens in a new tab)

  5. High-Speed Ultrasonic Pulse-Echo System for Two-Phase Flow Measurement

    … focuses on the design of a High Speed Ultrasonic Pulse-Echo system for two-phase flow parameter measurement. The ultrasonic system utilizes four ultrasonic (10 MHz frequency) transducers positioned in the axial direction on the surface of a 2.1 cm diameter cylindrical pipe, operating in pulse-echo …

    mcmaster Repository record for High-Speed Ultrasonic Pulse-Echo System for Two-Phase Flow Measurement (opens in a new tab)

  6. Compact Remote acoustic profiling of ocean sound speed using pulse-echo techniques

    … The methods presented are inspired by pulse-echo techniques used in medical ultrasound, but are adapted for a compact system that can be deployed on small vessels for ocean applications. The research introduces two primary methods for remote SSP estimation. The first method uses a …

    newfoundland Repository record for Compact Remote acoustic profiling of ocean sound speed using pulse-echo techniques (opens in a new tab) Embargoed until 2027-02-01

  7. Investigation of ultrasonic properties of MAGIC gels for pulse-echo gel dosimetry

    … ionising radiation dose verification. Pulse-echo ultrasound methods were investigated for the measurement and analysis of complex radiation therapy dose delivery.<br/><br/>The physical properties of MAGIC (Methacrylic and Ascorbic acid in Gelatin Initiated by Copper) polymer gel …

    soton Repository record for Investigation of ultrasonic properties of MAGIC gels for pulse-echo gel dosimetry (opens in a new tab)

  8. Investigation of a piezo-polymer array transducer for pulse-echo ultrasonic material examinations

    … investigation was to make a flexible array of pulse-echo ultrasound transducers by etching two orthogonal linear arrays of conducting elements into the metallisation of either side of a sheet of PVdF. These would then be multiplexed under computer control in an X-Y raster, thereby forming an …

    cranfield Repository record for Investigation of a piezo-polymer array transducer for pulse-echo ultrasonic material examinations (opens in a new tab)

  9. Development and Validation of Pulse-Echo Methods for the Detection of Buried Objects

    … the viability of using high-frequency seismic pulse-echo signals to detect buried objects ahead of a horizontal directional drilling (HDD) drill head at laboratory scale. A key novelty of this work is the subsurface, ahead-of-drill sensor configuration, in which the seismic source and receivers …

    vt Repository record for Development and Validation of Pulse-Echo Methods for the Detection of Buried Objects (opens in a new tab)

  10. Acoustooptical techniques for ultrasonic materials evaluation: optical fiber interferometry and pulse-echo systems

    … system are discussed. The second system is a pulse-echo transducer system that generates an electronically focusable ultrasonic field and detects the reflected field optically. The generating transducer consists of concentric ring electrodes etched on a single x-cut quartz crystal substrate …

    vt Repository record for Acoustooptical techniques for ultrasonic materials evaluation: optical fiber interferometry and pulse-echo systems (opens in a new tab)

  11. Inverse Problems in Pulse-Echo Ultrasound: Exploiting Coherence for Image Enhancement and Quantitative Imaging

    Whereas pulse-echo ultrasound imaging relied on focused acoustic waves since its inception, the last two decades have seen the development of techniques based on unfocused waves, including ultrafast ultrasound imaging. In large part due to the emergence of the latter, new methods able to image …

    epfl Repository record for Inverse Problems in Pulse-Echo Ultrasound: Exploiting Coherence for Image Enhancement and Quantitative Imaging (opens in a new tab)

  12. Oblique angle pulse-echo ultrasound characterization of barely visible impact damage in polymer matrix composites

    … characterization) the technique of oblique angle pulse-echo ultrasound is investigated. An understanding of oblique angle ultrasound wave propagation, reflection and diffraction are presented. Model results suggest oblique angle pulse-echo ultrasound is sensitive to hidden delaminations. However, …

    ohiolink Repository record for Oblique angle pulse-echo ultrasound characterization of barely visible impact damage in polymer matrix composites (opens in a new tab)

  13. Predicting Surface Heat Flux and Temperature via a Pulse-Echo Acoustic Transducer for Inverse Heat Conduction Applications

    … (passive side) of the sample and an ultrasonic pulse is released and timed (round-trip) in the sensor that produces the pulse. This time-of-flight measurement, using a pulse-echo arrangement, can be correlated to either surface temperature or heat flux. Regularization, a mathematical approach …

    ut-knoxville Repository record for Predicting Surface Heat Flux and Temperature via a Pulse-Echo Acoustic Transducer for Inverse Heat Conduction Applications (opens in a new tab)

  14. Novel high-resolution BAW ultrasonic sensors based on CMOS-compatible AlN transducers operated in a pulse-echo scheme

    Les tecnologies i els dispositius d’ones acústiques han estat en ús comercial per a telecomunicacions, detecció de pressió per a automoció, proves no destructives i atenció mèdica durant més de 60 anys; la seva aplicació també s’estén a la indústria i acadèmia, on es poden trobar desenes de sensors …

    barcelona Repository record for Novel high-resolution BAW ultrasonic sensors based on CMOS-compatible AlN transducers operated in a pulse-echo scheme (opens in a new tab)

  15. Evaluation of carbon fiber laminates via the use of pulse-echo ultrasound to quantify ply-stack orientation and manufacturing defects.

    … within carbon fiber laminates via the use of pulse-echo ultrasound. The first scientific contribution of this work is a method to determine the number of lamina and orientation of each lamina for plain weave carbon fiber laminates. Current methods to verify the ply stack are destructive, …

    baylor Repository record for Evaluation of carbon fiber laminates via the use of pulse-echo ultrasound to quantify ply-stack orientation and manufacturing defects. (opens in a new tab)

Page 1 of 12