Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 33 for “"Pulse-shape analysis"”
-
Pulse Shape Analysis Studies in Si(Li) Detector
… Numerical algorithms, which analyze detector pulse shape, were tested. A method to discriminate between electrons and gamma radiation using pulse shape analysis was demonstrated. The analysis was done on the data taken with <sup>207</sup><em>Bi</em> source using a semiconductor Si(Li) …
-
Digital Signal Processing for segmented HPGe Detectors, Preprocessing Algorithms and Pulse Shape Analysis
… spectrometer equipped with digital electronics. Pulse shape analysis algorithms to determine the interaction position of gamm-rays were implemented on a Digital Signal Processor and validated in an experiment using a collimated gamma-ray source. Emphasis was placed on the properties of the …
-
Energy non-linearity studies and pulse shape analysis of liquid scintillator signals in the Double Chooz experiment
… flux as well as their energy spectrum in the analysis of Theta13, which requires a detailed knowledge of the energy scale. In particular the non-linear scintillator response caused by ionization quenching and Cerenkov light has to be accurately reproduced in the Monte Carlo. To this end the …
-
Exploitation of pulse shape analysis for correlated background rejection and ortho-positronium identification in the Double Chooz experiment
La mesure récente de l'angle de mélange theta-13, à laquelle l'expérience Double Chooz contribue, a ouvert la voie aux futures expériences de la physique des neutrinos. Dans ce manuscrit, la caractérisation de certains bruits de l'expérience sont décrits. Les muons cosmiques qui s'arrêtent et se …
-
Study of the Compton imaging capabilities of a highly segmented HPGe detector using a machine-learning-based pulse-shape analysis method
Cette thèse explore les capacités d'imagerie Compton d'un détecteur HPGe coaxial segmenté. Un modèle léger d'apprentissage automatique est développé pour reconstruire les positions d'interaction à partir des formes d'impulsion, permettant une imagerie précise sans recourir à une ferme de calcul. …
-
Pulse Shape Analysis for the GERDA Experiment to Set a New Limit on the Half-life of Neutrinoless Double Beta Decay of Ge-76
… active background reduction techniques such as pulse shape discrimination (PSD) in which the time structure of the germanium signals is analyzed to discriminate signal- from background-like events. Two types of HPGe detectors are operated: semi-coaxial detectors previously used in the …
-
Optimization of the performance of a pixellated germanium Compton camera
… sources of Cs137, line sources and clinical-like shape distributed sources. Experimental results are obtained to study the e ffects of energy resolution, position sensitivity, and reconstruction algorithms on camera images. Preamplifi ed pulses are digitized for pulse shape analysis using gamma …
-
Part A: Detectors for 10.6 Micron Tea CO2 Laser Radiation, Part B: Modulator for Active Mode-Locking
… For the measurement of the energy of pulses of 10.6 μm laser radiation for energies up to 15-20 joules and also for energies up to 200 joules, two pyroelectric detector designs were researched. These two detector designs acted as monitors, using 10% of the beam for detection and …
-
An Axion Search With The Majorana Demonstrator
… signals from noise at the lowest energies. New pulse shape analysis (PSA) techniques have been developed to remove electronics noise, and reject energy-degraded “slow” events in the data. A novel training set of low energy small-angle Compton scatter events is used to determine the efficiency of …
-
Construction of a compton-camera prototype based on silicon scatterer with analytical image reconstruction for medical imaging
… from the designed device by applying novel analysis techniques (pulse shape analysis) to recorded digital signals.
-
Alpha-event characterization for germanium detectors
… located at the MPI f¨ur Physik in Munich. Pulse shape analysis was performed to identify the characteristics of alpha events. The properties of the detector directly underneath the passivation layer on the end-plate were also studied. As part of the detector characterization, the thickness …
-
DEVELOPMENT AND CHARACTERIZATION OF AN INNOVATIVE LOW-NOISE HIGH-DYNAMIC-RANGE VLSI CHARGE-SENSITIVE PREAMPLIFIER FOR SOLID-STATE DETECTORS EMPLOYED IN NUCLEAR PHYSICS EXPERIMENTS WITH RADIOACTIVE ION BEAMS
… installed on a dedicated PCB and tested using a pulser. We then designed and realized a preamplifier board with eight ASICs for a total of 32 front channels and one back channel. We connected it to a highly-segmented planar silicon detector and acquired the spectrum of a 241Am-244Cm-239Pu triple …
-
Characterisation of a LaBr3:LaCl3 Phoswich Array Using 70-230 MeV Protons
… Integral and correlation based on-line pulse-shape analysis tools are evaluated, optimised, and used to interpret the data. In particular, the energy deposited in the LaBr3(Ce) and the energy deposited in the LaCl3(Ce) are separated from each other, and it is demonstrated that the …
-
Development and Demonstration of an Ultra-Low-Background Liquid Scintillation Counter
… capabilities, and alpha/beta separation by pulse shape analysis. The ULB LSC broadens trace level measurement capabilities that will impact applications in nuclear nonproliferation, treaty verification, and environmental and geochemical science studies.
-
CRISPR SCREEN FOR PROTEIN INCLUSION FORMATION UNCOVERS SRRD AS A NOVEL REGULATOR OF AGGRESOME FORMATION AND CELLULAR PROTEOSTASIS
… for TDP-43 and FUS that, when coupled to Pulse Shape Analysis (PulSA), a FACS based methodology, enabled detection of protein inclusions at the single cell level. These reporters were leveraged against genome-wide CRISPR-Cas9 screens and protein disaggregase systems to find novel modifiers …
-
Temperature quenching in LAB based liquid scintillator and muon-induced backgrounds in the SNO+ experiment
… stronger for α-particles (−0.35 ± 0.03) %/° C. A pulse shape analysis shows increased strength of a slow decay component at lower temperatures, pointing to reduced non-radiative triplet state de-excitations at lower temperatures. Furthermore, this work found upper bounds for the in-situ …
-
Natural Radioactive Background Suppression in 76Ge Neutrinoless Double-β Decay Experiments
… to determine the optimal technology and data analysis methods for LEGEND-1000. This work will discuss pulse shape analysis contributions to the Majorana Demonstrator’s final result half-life sensitivity of 8.3×1025 years and silicon photomultiplier characterization results relevant for …
-
Studies of the responses of liquid and solid targets for direct dark matter searches.
… off sodium nuclei in the crystal. Cuts on pulse shape discrimination in BC501A and neutron time of flight have been performed on pulses recorded by an Acqiris DC265 digitiser with a 2 ns sampling time. A quenching factor of 25.2 ± 6.4% has been determined for 10 keV sodium recoils. Measured …
-
Beta decay of neutron-rich isotopes of zinc and gallium
… time resolution through the use of a pulse-shape analysis algorithm, which is sufficient for use in experiments with the requirement for the fast timing. The detector ability to survive after implanting high-energy ions was tested using a laser that simulated energy of 1 GeV. The …
-
PYGMY STRUCTURES IN 208PB AND 90ZR STUDIED WITH THE INELASTIC SCATTERING OF 17O AT 20 MEV/U
… generation HPGe array based on the techniques of pulse shape analysis and gamma-ray tracking. The Demonstrator was coupled to an array of 3 large volume LaBr3:Ce scintillators to increase the total efficiency; the remaining solid angle was covered by 20 BaF2 scintillators. Two segmented ΔE-E Si …
Page 1 of 2