Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 10 of 10 for “"Pulsed currents"”

  1. The dynamic characterisation and modelling of lead-acid batteries for electric vehicle applications

    … capacity of a lead-acid battery, the effects of pulsed discharge currents as opposed to the effects of continuous discharge currents on the battery were investigated, for a wide range of frequency, mark/space ratio and peak current of the discharge waveform. It was found that for certain …

    southwales Repository record for The dynamic characterisation and modelling of lead-acid batteries for electric vehicle applications (opens in a new tab)

  2. Electro-mechanical analysis of thin-film substrate fuses using finite element methodology.

    … multilayer fuse geometries for DC and repetitive currents. The critical electro-thermally-induced stresses and strains were identified, and the techniques to achieve a reduction in the magnitude of these stresses & strains were investigated. Computational tools were developed to enable the …

    sheffield-hallam Repository record for Electro-mechanical analysis of thin-film substrate fuses using finite element methodology. (opens in a new tab)

  3. Controlling the dimensionality of the Stern-Gerlach effect for neutral atom manipulation

    … beam. By adjusting the bias field via variable, pulsed currents, we demonstrate the transition from a purely dispersive kick to a one-dimensional kick where off-axis heating of the beam has been eliminated. Pure one-dimensional forces enable access to new atomic and molecular cooling methods that …

    texas Repository record for Controlling the dimensionality of the Stern-Gerlach effect for neutral atom manipulation (opens in a new tab)

  4. Cellular level studies and coil system design for transcranial magnetic stimulation

    … Parkinson's disease and PTSD. It uses pulsed currents in the coils to generate time varying magnetic field which induce eddy currents in the conductive tissues of human brain. Recently, there are several research publications in the field of TMS, specifically on coil designs, clinical …

    iastate Repository record for Cellular level studies and coil system design for transcranial magnetic stimulation (opens in a new tab)

  5. Simulation of lithium-ion batteries based on pulsed current characterization

    … the local (depth dependent) charge state. A pulsed discharge and charge technique is put forth for extracting the model parameters, and their dependence on cell state of charge. The extraction method is applied to commercial lithium-ion cells. It is shown that the extracted parameters are …

    ubc Repository record for Simulation of lithium-ion batteries based on pulsed current characterization (opens in a new tab)

  6. Time-resolved domain wall motion in novel spin transfer torque devices

    … the effect of bias field on DW motion. Using pulsed currents, spin transfer torque-driven domain wall motion was demonstrated in these artificial domain structures and the DW position and velocity tracked using time-resolved EHE measurements.

    bath Repository record for Time-resolved domain wall motion in novel spin transfer torque devices (opens in a new tab)

  7. Performance Enhancement of Organic Light-Emitting Diodes with an Inorganically Doped Hole Transport Layer

    … stress tests under continuous wave and pulsed currents were conducted to gain a better understanding of the key factors governing the degradation process of phosphorescent OLEDs. Through comparative studies of the aging behaviors of OLEDs with different hole transport layers (HTLs) under …

    wvu Repository record for Performance Enhancement of Organic Light-Emitting Diodes with an Inorganically Doped Hole Transport Layer (opens in a new tab)

  8. Galvanically isolated wide-band current sensors

    … current sensors capable of monitoring precisely pulsed currents varying from DC up to frequencies as high as 100KHz and of reading current alteration rates as high as 10GA/sec. This requirement sets the sensor bandwidth specification to at least 1MHz for 5KA maximum current amplitude and …

    greece Repository record for Galvanically isolated wide-band current sensors (opens in a new tab)

  9. Étude expérimentale et numérique du frittage-assemblage d’un composite conducteur l’Ag-SnO2 par courants pulsés

    Ces travaux de thèse s’inscrivent dans le cadre du projet "IMPULSE" qui traite du développement d’un procédé innovant d’élaboration de multi-matériaux par courant pulsé et est financé par l’Agence National de la Recherche. Ils ont pour objectif d’étudier et de mettre en évidence la faisabilité, du …

    star-france Repository record for Étude expérimentale et numérique du frittage-assemblage d’un composite conducteur l’Ag-SnO2 par courants pulsés (opens in a new tab) Restricted access

  10. Comportement électrochimique d'électrolytes Zinc Fer à haute teneur en Fer, germination et effet des courants pulsés.

    La mise au point de revêtements anticorrosion présente à la fois un enjeu économique et un défi environnemental. En effet de nombreuses contraintes sont apparues dans le domaine des traitements de surface au cours des dernières décennies, du fait de la mise en application de restrictions sur …

    star-france Repository record for Comportement électrochimique d'électrolytes Zinc Fer à haute teneur en Fer, germination et effet des courants pulsés. (opens in a new tab)