Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 19 of 19 for “"Pump-probe method"”
-
Selektyviai sužadintų krūvininkų dinamika kolegiruotame ir nekolegiruotame scintiliatoriuje GAGG:Ce /
… scintillator GAGG:Ce has been analyzed by using pump-probe method. It is evident that shallow charge traps play an essential role in transfering electrons from conduction band of GAGG to Cerium ions. In order to broaden the knowledge behind the origin of electron traps and their role in …
-
Lazeriu sukelto nuovargio efekto ir ultraspartaus optinio atsako sąsajos tyrimas dielektrinėse optinėse dangose /
… base. The experiment was performed using two methods: laser-induced damage threshold S-on-1 method and time-resolved digital holography pump-probe method. Using the first technique, the characteristic damage curves for each sample were calculated, from which it is clear that increasing the …
-
Fundamental Studies And Applications Of Strong Field Ionization
… directly to the continuum. We used this method to study several aspects and applications of strong field ionization (SFI) in atoms and molecules. One study used SFI to probe the photofragments produced by photodissociation using DC sliced imaging. The photodissociation mechanism of two …
-
Determining Effective Lifetime of Minority Carriers in Silicon Through Modulated Free Carrier Absorption
… is directly related to device efficiency. Pump-probe techniques, in which a pump laser of photon energy above the bandgap energy of the material is used to excite free carrier populations while a sub-bandgap probe laser is used to monitor the change in excess carrier density have been …
-
Novel Free-Carrier Pump/Probe Techniques for the Characterization of Silicon
Two novel pump/probe techniques have been developed for measuring the recombination lifetime in crystalline silicon wafers. The first technique, single-beam pump/probe, uses one laser as both pump and probe. The second technique, quasi-steady state free-carrier absorption, measures lifetime under …
-
Protein Mechanics Through X-Ray Crystallography
… functions. Despite the success of biophysical methods in determining the physical structures of proteins--that is, the precise three-dimensional configuration of all of their constituent atoms--no comprehensive physical models exist which accurately describe or predict the conformational …
-
Study Of The Birefriengence Of Black Phosphorus By Picosecond Interferometry
… presents a modified picosecond interferometry method to study the optical properties of bulk black phosphorus (BP). BP is an emerging two-dimensional material which exhibits great potential for use in future nano-photonic and nano-electronic devices. BP differentiates itself from other …
-
Ultrafast Laser-induced Magnetisation Dynamics: Gilbert damping of Metal and Half-metal
… and half-metals is studied using an all-optical pump-probe method: the time-resolved magneto-optic Kerr effect (TR-MOKE), combined with several advanced characterization techniques, such as angle-resolved photoemission spectroscopy (APRES) and X-ray magnetic circular dichroism (XMCD). In …
-
The Photophysics of Azulene and Related Compounds in Solution
… states of azulene and five of its derivatives. A pump-probe spectrometer with sub-picosecond temporal resolution was employed to obtain the very short population relaxation times of the nonemitting S1 states of azulene and related compounds as a function of the solvent polarity, the solvent …
-
Ultra-fast dynamics in atoms and molecules during photoionization: from attoseconds to femtoseconds
… in the time domain for the first time, using a pump–probe method with attosecond pulses and electron interferometry (RABBIT). Theoretical development in combination with a coincident measurement of the two electrons revealed a 500 as group delay of the photoelectron pair from xenon, with respect …
-
Thermophysical properties study of graphene
… graphene and Si is evaluated. A transient pump-probe method is designed for interfacial thermal resistance characterization.</p>
-
Study of transient effects in photo-excited semiconducting polymers
… performance of the polymer OPV devices. Optical pump-Terahertz (THz) probe time domain spectroscopy (OPTP-TDS) is a noncontact technique which combines THz time domain spectroscopy and the pump-probe method. OPTP-TDS provides the ability to study the transient properties of photoexcited …
-
Testing theories for thermal transport using high pressure
… and across interfaces, using an ultrafast pump-probe method, time-domain thermoreflectance (TDTR), combined with gem anvil cell techniques. I demonstrated that pressure tuning of physical properties of materials is an elegant approach to test the validity of theories for thermal transport. …
-
Excited state dynamics of isolated DNA base pairs and related chromophore clusters
… of these states was investigated using a pump-probe method. The obtained experimental results were analyzed with the help of ab initio and semi-empirical calculations. In a model system 2-aminopyridine dimer ((2-AP)2), an intermolecular proton-coupled electron transfer reaction was …
-
Femtosekunden-Spektroskopie biologischer Systeme mittels kohärenter Kontrolle
… carotenoid donor of the same complex. The pump-probe method using shaped excitation pulses is shown to be successful for the first time in controlling the natural function of a biological system, namely the flow of excitation energy in the complex network of states in LH2. By means of a …
-
Absorptive And Refractive Optical Nonlinearities In Organic Molecules And Semiconductors
… Both linear and nonlinear characterization methods are described. Linear spectroscopic characterization includes absorption, fluorescence, quantum yield, anisotropy, and singletoxygen generation measurements. Nonlinear characterization, performed by picosecond and femtosecond laser systems …
-
Nonlinear Optics and Carrier Dynamics in Nanostructured and Two-Dimensional Materials
… silicon optical waveguides using a novel pump-probe method. A two-frequency heterodyne technique is developed in order to measure the pump-induced transient change in phase and intensity in a single measurement. The experimental data reveal a characteristic material response time and …
-
THERMAL TRANSPORT PROPERTIES OF ULTRAWIDE BANDGAP SEMICONDUCTORS FOR NEXT GENERATION POWER ELECTRONICS
… were systematically studied using the optical pump-probe method of frequency-domain thermoreflectance (FDTR). Our results show that k increases with thickness and k values are among the highest reported for film thicknesses of 200 nm, 500 nm and 1 μm, with values of 71.95, 152.04, and 195.71 …
-
Electronic and Vibrational Dynamics of Heme Model Compounds-An Ultrafast Spectroscopic Study
<p>The ultrafast electronic and vibrational dynamics of a model five-coordinate, high-spin heme Fe<sup>II</sup>OEP-2MeIm, following excitation in the Soret band, have been studied in a coordinated fashion using ultrafast transient absorption, time-resolved Stokes and anti-Stokes resonance Raman …