Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 46 for “"Punching shear failure"”.

  1. Punching shear failure of foundations on strong sand overlying deep weak deposit

    … several theories can be found using simplified failure mechanisms in conjunction with the punching shear failure. Accordingly, assumptions were used to simplify the evaluation of the level of mobilization of the shear strength on the punching column. This is mainly due to the complexity of …

    concordia Download PDF for Punching shear failure of foundations on strong sand overlying deep weak deposit (opens in a new tab)

  2. An investigation into the punching shear failure in R.C. waffle slabs subjected to concentrated load

    … when subjected to concentrated loads. The punching shear failure inside waffle slabs has not been thoroughly investigated and this is also reflected in the current code of practice, which, in the main, relates the design of punching shear in waffle slabs to that in solid slabs. In this …

    abertay Repository record for An investigation into the punching shear failure in R.C. waffle slabs subjected to concentrated load (opens in a new tab) Download PDF for An investigation into the punching shear failure in R.C. waffle slabs subjected to concentrated load (opens in a new tab)

  3. An experimental study and finite analysis of punching shear failure in steel fibre-reinforced concrete ground -suspended floor slabs

    … effect of using steel fibre-reinforcement on the punching shear behaviour of ground-suspended slabs with internal columns. The main objectives of this research were to develop a constitutive model for steel fibre-reinforcement (SFRC), to study experimentally the punching shear behaviour of SFRC …

    liverpool-jm Repository record for An experimental study and finite analysis of punching shear failure in steel fibre-reinforced concrete ground -suspended floor slabs (opens in a new tab) Download PDF for An experimental study and finite analysis of punching shear failure in steel fibre-reinforced concrete ground -suspended floor slabs (opens in a new tab)

  4. Characterization of Punching Shear Capacity of Thin Uhpc Plates

    … and contained no reinforcing steel to resist shear. The lack of steel reinforcement allowed for the possibility of a punching shear failure to occur from the application of a point load such as a wheel tire patch load. The model and optimized section served as the foundation for this research, …

    vt Repository record for Characterization of Punching Shear Capacity of Thin Uhpc Plates (opens in a new tab)

  5. Fatigue Behaviour of GFRP-Reinforced UHPC Closure Strips in Prefabricated Bridge Deck Applications

    … fatigue loads at service levels as well as at failure loads. Four nearly full-scale (150 mm deep) bridge deck specimens were constructed, each consisting of two panels connected by a UHPC filled closure strip. Two of the specimens were reinforced with ribbed glass fibre reinforced polymer …

    waterloo Repository record for Fatigue Behaviour of GFRP-Reinforced UHPC Closure Strips in Prefabricated Bridge Deck Applications (opens in a new tab)

  6. Effects of Vertical Ground Motion on Seismic Performance of Reinforced Concrete Flat-Plate Buildings

    … the regions of high seismicity, moment frames or shear walls are employed to resist lateral loading while the flat-plate system is designed to primarily resist gravity loading. Flat-plate structures must maintain lateral deformation capacity as well as resist gravity loading under seismic loads. …

    unlv Repository record for Effects of Vertical Ground Motion on Seismic Performance of Reinforced Concrete Flat-Plate Buildings (opens in a new tab) Download PDF for Effects of Vertical Ground Motion on Seismic Performance of Reinforced Concrete Flat-Plate Buildings (opens in a new tab)

  7. Structural Performance of Reinforced Concrete Flat Plat Buildings Subjected to Fire

    … buildings. Flat plate construction is prone to punching shear failure at slab-column connections which may lead to a catastrophic progressive collapse. The slabs of flat-plates generally have very thin concrete cover leaving steel reinforcement more sensitive to thermal loads. Little is known in …

    unlv Repository record for Structural Performance of Reinforced Concrete Flat Plat Buildings Subjected to Fire (opens in a new tab) Download PDF for Structural Performance of Reinforced Concrete Flat Plat Buildings Subjected to Fire (opens in a new tab)

  8. Punching shear behaviour of slab-column edge connections reinforced with fibre-reinforced polymer (FRP) composite bars

    … compared to steel bars which results in a lower shear capacity of FRP reinforced concrete (RC) elements compared to steel-RC elements. Flat plate systems are commonly used to take advantages of the absence of beams. They, however, are susceptible to punching shear failure where the column …

    manitoba Repository record for Punching shear behaviour of slab-column edge connections reinforced with fibre-reinforced polymer (FRP) composite bars (opens in a new tab)

  9. Strength of edge column-slab connections of post-tensioned concrete flat plates.

    … the load up to 5.8 kN/m$\sp2$ (0.85 psi). Punching shear failure happened at a load of 23.6 kN/m$\sp2$ at the edge column-slab connection #2. The failed connection(s) were repaired and shored, tendons re-tensioned and the slab reloaded to fail the next connection. To investigate the …

    ottawa-retro Repository record for Strength of edge column-slab connections of post-tensioned concrete flat plates. (opens in a new tab)

  10. Performance of Pile Cap Foundation with Respect to Cap Rigidity

    … piles, as well as resisting bending moments and punching shear failure, but may impose additional load on the foundation. In view of these differences, there is a need to determine an optimal cap thickness such that the cap will distribute the load evenly on the piles without imposing excessive …

    concordia Download PDF for Performance of Pile Cap Foundation with Respect to Cap Rigidity (opens in a new tab)

  11. Rehabilitation of reinforced concrete slab-column connections for two-way shear

    … structural system, it is prone to brittle shear failure at slab-column connections, which may result in the progressive collapse of a building. For that reason, connections with insufficient two-way shear strength may need to be rehabilitated and rehabilitation can be a cost-effective …

    texas Repository record for Rehabilitation of reinforced concrete slab-column connections for two-way shear (opens in a new tab)

  12. Punching Shear and Flexural Capacity Modeling and Experimental Testing of Bridge Slab Segments

    Punch-through shear failure is a common bridge deck damage mode in which a high concentrated load, typically from the wheel of a heavy vehicle, induces a localized shear failure conducted through the full-depth of the slab. This research project discussed hereafter investigated the structural …

    tamu Repository record for Punching Shear and Flexural Capacity Modeling and Experimental Testing of Bridge Slab Segments (opens in a new tab) Embargoed until 2027-12-01

  13. Punching Shear and Flexural Capacity Modeling and Experimental Testing of Bridge Slab Segments

    Punch-through shear failure is a common bridge deck damage mode in which a high concentrated load, typically from the wheel of a heavy vehicle, induces a localized shear failure conducted through the full-depth of the slab. This research project discussed hereafter investigated the structural …

    tamu Repository record for Punching Shear and Flexural Capacity Modeling and Experimental Testing of Bridge Slab Segments (opens in a new tab) Embargoed until 2027-12-01

  14. Punching Shear and Flexural Capacity Modeling and Experimental Testing of Bridge Slab Segments

    Punch-through shear failure is a common bridge deck damage mode in which a high concentrated load, typically from the wheel of a heavy vehicle, induces a localized shear failure conducted through the full-depth of the slab. This research project discussed hereafter investigated the structural …

    tamu Repository record for Punching Shear and Flexural Capacity Modeling and Experimental Testing of Bridge Slab Segments (opens in a new tab) Embargoed until 2027-12-01

  15. Punching Shear and Flexural Capacity Modeling and Experimental Testing of Bridge Slab Segments

    Punch-through shear failure is a common bridge deck damage mode in which a high concentrated load, typically from the wheel of a heavy vehicle, induces a localized shear failure conducted through the full-depth of the slab. This research project discussed hereafter investigated the structural …

    tamu Repository record for Punching Shear and Flexural Capacity Modeling and Experimental Testing of Bridge Slab Segments (opens in a new tab) Embargoed until 2027-12-01

  16. A critical review of the symmetric punching shear of reinforced concrete flat slabs.

    … composite bridge deck showed that the ultimate punching shear load depends on the shape of the loaded area, the compressive strength of concrete, the flexural reinforcement ratio and on the arrangement of steel bars. Punching failure follows the formation of an inclined failure surface from the …

    ottawa-retro Repository record for A critical review of the symmetric punching shear of reinforced concrete flat slabs. (opens in a new tab)

  17. Fatigue response of fabric reinforced polymeric composites

    … applications. The first deck failed due to local punching shear failure after 230,000 cycles. The second deck was reinforced in the loading area with 100 oz/yd2 of fiber in the transverse direction. No damage was observed for two million cycles and there was no considerable degradation in bending …

    wvu Repository record for Fatigue response of fabric reinforced polymeric composites (opens in a new tab)

Page 1 of 3