Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 16 of 16 for “"Push-off test"”
-
Upgrading the push-off test to analyze the contribution of steel fiber on shear transfer mechanisms
… increasing ultimate resistance and ductility. Push-off tests had been used to study the mechanisms of concrete shear transfer. Shear strength of the specimen depends on the contribution of both concrete and reinforcement. Aggregate interlock has a significant contribution to the concrete shear …
-
Evaluation of deck fasteners functioning as shear connectors for composite steel joists
… steel joists is studied. Results of thirty-six push-off tests are evaluated in terms of strength and behavior. Six types of deck fasteners are considered. They are: 1. #12-24 Teks/5 self-drilling, self-tapping screws. 2. 1/4-14 Teks/3 with a 1 1/4 in. stand-off sleeve. 3. 1/4-14 Teks/3 with a 1 …
-
Structural performance of a novel sustainable and demountable composite floor system - recycled aggregate concrete-steel composite beam utilising demountable shear connectors
… and this research responds to that necessity by offering an innovative flooring system that integrates RAC with demountable shear connectors, specifically for application in temporary and short-term leasing structures. A literature study on concrete microstructure indicated that residual mortar …
-
Strength of welded headed studs in ribbed metal deck on composite joists
… in the deck flute is investigated. Thirty-six push-off specimens were tested with three different deck geometries. A normal load apparatus models gravity loading in an attempt to represent full-scale joist behavior during the push-off test procedure. The results illustrate that the current AISC …
-
Shear Performance of Non-Traditional Concrete
… and science and technology continually push the previously believed limits. Two such types of concrete are self-consolidating concrete (SCC) and cement-limiting concrete. While each is vastly different from the other, they present similar problems to designers and engineers. …
-
Experimental investigation of factors influencing interface shear strength
… through an experimental study comprising 21 push-off test specimens. Five key variables were examined: interface roughness, concrete shear area, reinforcement ratio, reinforcement detailing, and cyclic loading. The specimens were tested to failure to characterize the complete spectrum of …
-
Interface Shear Transfer in Reinforced Concrete Members: Code Evaluation, Modeling, and Testing
… demonstrating a new method for experimentally testing IST. Firstly, a database of IST experiments on uncracked reinforced concrete specimens was created from published test results. A total of 774 tests were reviewed, with data coming from tests conducted between 1969 and 2014. Once compiled, …
-
Behaviour of demountable shear connectors in composite structures
… shear connectors in composite structures through push off tests and composite beam tests. Push off tests were conducted to examine the shear strength, stiffness and ductility of demountable shear connectors in composite structures. The experimental results showed that demountable shear connectors …
-
Caracterização de depósitos realizados pelo processo de deposição por fricção em chapas de aço de alto carbono
… (ZTA), resistência de adesão do depósito (push-off test), macrografias, micrografias em microscópio óptico (MO) e em microscópio eletrônico de varredura (MEV), perfis de microdureza e análise térmica. Os depósitos realizados com força axial de 13,7 kN, velocidade de avanço de 17 mm/s e …
-
Simulated fall arrest upper extremity biomechanics and strength relationships in healthy older males and females
… a movement similar to the downward phase of a push-up, and quick release (QR) forward fall landing simulations using a novel rig apparatus. Three trials were recorded for each condition at 30° body lean from vertical. Biomechanical measures included range of motion, maximum joint moments, …
-
Dynamic performance of pre-cast prestressed beams – cast in-situ slab composite bridges
… as ultrasonic techniques, radar method, impact testing, magnetic based methods and proof load tests are limited to small areas, time consuming and require prior knowledge of the damaged zone. These limitations can be overcome by using dynamics-based techniques. The main objective of this work is …
-
Enhancing Shear Strength of Post-tensioned Precast Concrete Bridge Girders Using External Prestressing: Experimental and Analytical Investigation
… of duct in the web. Moreover, a series of 27 push-off concrete specimens (600 x 400 mm) with and without ducts have been tested to examine the effects of different duct diameter-to-web thickness ratios on the direct concrete shear strength. A 3D finite element model for the push-off specimens, …
-
Composite Action in Prestressed NU I-Girder Bridge Deck Systems Constructed with Bond Breakers to Facilitate Deck Removal
Results are reported from tests of small scale push-off and large-scale composite NU I-girder specimens conducted to establish an interface connection detail that 1) Facilitates in-situ removal of the bridge deck without damaging prestressed girders and 2) Maintains composite action between the …
-
Development of self-lubricating icephobic coatings
… wind tunnel (IWT) and a custom-made ice adhesion test rig was designed and manufactured to measure the ice shear strength. The first part of this study mainly aims to qualitatively evaluate the icephobicity performance of a PTFE solid lubricant film with a custom-built push-off test device in …
-
Effectiveness of polypropylene fibres as shear reinforcement in structural elements
… the shear behaviour of PFRC is evaluated by push-off specimens. The second level involves studying shear in real scale elements. For this purpose, shear critical slender beams were manufactured and tested. The last level corresponds to real application of polypropylene fibres to act as shear …
-
Structural performance of CFRP composites in UHPC sandwich walls and shock absorbing prosthetic pylons
… and without anchor heads using standard pullout test. A total of 48 specimens were tested to evaluate the influence of fibre type in UHPC (steel and POM fibre) and anchor geometry on bond performance. Anchor-headed specimens developed higher peak pullout loads than straight CFRP strip specimens. …