Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 54 for “"Pyrex glass"”

  1. Three mechanisms of breakdown of pyrex glass

    Thesis (B.S.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering, 1929.

    mit Repository record for Three mechanisms of breakdown of pyrex glass (opens in a new tab)

  2. Design And Fabrication Of Microfluidic Devices For Electrokinetic Studies

    … several materials including silicon, Pyrex glass, and polymer were explored. Inductively-coupled plasma reactive ion etching (ICP-RIE) was employed for fabrication of microfluidic channels on silicon and Pyrex glass and photolithography of SU-8 polymer was used to pattern microfluidic …

    ohiolink Repository record for Design And Fabrication Of Microfluidic Devices For Electrokinetic Studies (opens in a new tab)

  3. CONTRIBUTIONS TO THE DEVELOPMENT OF A NOVEL METHOD IN LOW TEMPERATURE BONDING OF SILICON-SILICON AND GLASS-GLASS

    … silicon-silicon and thick silicon dioxide-Pyrex glass. Silicon-silicon bonding was achieved at 300 degrees centigrade with intermediate doped silicon dioxide layer (0.5-0.7 microns thick). Pyrex glass was successfully bonded to very thick silicon dioxide (2 microns thick) at 450-500 degrees …

    ohiolink Repository record for CONTRIBUTIONS TO THE DEVELOPMENT OF A NOVEL METHOD IN LOW TEMPERATURE BONDING OF SILICON-SILICON AND GLASS-GLASS (opens in a new tab)

  4. A silicon micromachined subminiature condenser microphone : analysis, design, fabrication and testing

    … the silicon membrane and the other the Pyrex glass (#7740) which forms the backplate. Between the capacitance circuit. Lithographic techniques are used to manufacture the condenser microphone with specially shaped backplates which contain the airgap and side volume cavity. An Anodic …

    concordia

  5. The Design and Fabrication of a Microfluidic Reactor for Synthesis of Cadmium Selenide Quantum Dots Using Silicon and Glass Substrates

    … (QDs) was synthesized out of a silicon wafer and Pyrex glass. Microfabrication techniques were used to etch channels into the silicon wafer. Holes were wet-drilled into the Pyrex glass using a diamond-tip drill bit. The Pyrex wafer was anodically bonded to the etched silicon wafer to enclose the …

    calpoly Repository record for The Design and Fabrication of a Microfluidic Reactor for Synthesis of Cadmium Selenide Quantum Dots Using Silicon and Glass Substrates (opens in a new tab)

  6. Low frequency Raman scattering in amorphous materials: fused quartz, "pyrex" boro-silicate glass and soda-lime silicate glass

    … in the region 20 to 100 cm -1 for fused quartz, "pyrex" boro-silicate glass, and soft soda-lime silicate glass was investigated. The Raman spectra for the fused quartz and the pyrex glass were obtained at room temperature using the 488 nm exciting line of a Coherent Radiation argon-ion laser at …

    brock Repository record for Low frequency Raman scattering in amorphous materials: fused quartz, "pyrex" boro-silicate glass and soda-lime silicate glass (opens in a new tab)

  7. Heat and mass transfer models of the University of Tennessee at Chattanooga distillation column

    … the University of Tennessee at Chattanooga is a Pyrex glass unit with 12 separation stages, overhead receiver and a reboiler as shown on figure 8. In this thesis, mathematical models that relate to heat and mass transfer during a binary distillation of methanol-water mixture are developed and …

    utc Repository record for Heat and mass transfer models of the University of Tennessee at Chattanooga distillation column (opens in a new tab)

  8. Viscosities of phase-separated glasses

    … on viscosity were analysed for three types of glasses. "Pyrex" glass could be approximated to a Newtonian liquid in the range of temperature 470 to 590°C. The activation energy for viscous flow varied from 65 to 85 kcal/mole according to the previous thermal history. All glasses exhibited phase …

    ubc Repository record for Viscosities of phase-separated glasses (opens in a new tab)

  9. Filmwise Condensation in a Vertical Tube in Counter-current and Co-current Flow�

    … and conduction heat transfer through the pyrex glass wall were calculated from heat transfer correlations, and then compared to the ones obtained from the Wilson Line Method applied to the data. In addition. for counter-current flow, the flooding point was also computed by the …

    okstate Repository record for Filmwise Condensation in a Vertical Tube in Counter-current and Co-current Flow� (opens in a new tab)

  10. A factorial approach to the study of alkali-silica reaction in concrete

    … reactive aggregates in laboratory tests (namely Pyrex glass and Beltane opal) were studied. In general the experimental work was carried out using standard test methods as specified by the British Standards Institution and the American Society for Testing and Materials. In particular the "mortar …

    city-london Repository record for A factorial approach to the study of alkali-silica reaction in concrete (opens in a new tab)

  11. An experimental apparatus to study nucleate pool boiling of R-114 and oil mixtures

    … The evaporator was made of a T-shaped Pyrex glass container. Boiling occurred from a smooth, hard-copper tube, 15.9 mm (5/8 in.) in outer diameter, 12.7 mm (1/2 in.) in inside diameter and 431.8 mm (17 in.) in length. The tube was heated using a cartridge heater, and it was instrumented …

    nps Repository record for An experimental apparatus to study nucleate pool boiling of R-114 and oil mixtures (opens in a new tab)

  12. Stress relaxation of glass using a parallel plate viscometer

    … the traditional method for manufacturing optical glass lenses. However, for a few years now, precision glass molding has gained importance for its flexibility in manufacturing aspheric lenses. With this new method, glass viscoelasticity and more specifically stress relaxation are important …

    clemson Repository record for Stress relaxation of glass using a parallel plate viscometer (opens in a new tab)

  13. Developing a spin polarized helium ion source for surface electronic structure studies

    … to produce metastable helium atoms in a clean pyrex glass cell. A 300 mW Ti:sapphire laser operating at 1.083 $\mu$m is used to optically pump the He(2$\sp3$S) atoms on the $\rm 2\sp3S\sb1\leftrightarrow 2\sp3P\sb1\ (D\sb1)$ transition to preferentially populate the $\rm He(2\sp3S)\ …

    rice Repository record for Developing a spin polarized helium ion source for surface electronic structure studies (opens in a new tab)

  14. A study of the physical adsorption of nitrogen gas on polished 347 stainless steel at very low pressures

    … for nitrogen physically adsorbed on 7740 Pyrex glass at 77.4° K. This well studied experiment was repeated in order to evaluate the vacuum system and dynamic technique used before studying the polished stainless steel. An error analysis of the dynamic technique indicated a maximum …

    vt Repository record for A study of the physical adsorption of nitrogen gas on polished 347 stainless steel at very low pressures (opens in a new tab)

  15. Novel design of a passive microfluidic mixer for biochemical reactions and biosensing

    … UV photolithography on silicon and bonded with pyrex glass by anodic bonding. To test the actual device mixing efficiency, we used a fluorescent dye rhodamine B solution to mix with DI water and put the devices under fluorescent microscope observations for real-time analysis. Images of …

    tamu Repository record for Novel design of a passive microfluidic mixer for biochemical reactions and biosensing (opens in a new tab)

Page 1 of 3