Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 138 for “"Q value"”.

  1. Policy Extraction via Online Q-Value Distillation

    … rules that transparently reconstruct the value function for all possible states. It convincingly beats performance benchmarks provided by earlier policy distillation methods resulting in performance closest to the original Deep Learning policy.

    waterloo Repository record for Policy Extraction via Online Q-Value Distillation (opens in a new tab)

  2. Identification of Differentially Expressed Genes and Gene Sets Using a Modified Q-Value

    … paper compares a recently proposed modified q-value method that takes into account such patterns to a traditional q-value method for experiments with three treatments. The results of simulation studies performed suggest that the proposed methods improve upon the traditional method in the …

    ndsu Repository record for Identification of Differentially Expressed Genes and Gene Sets Using a Modified Q-Value (opens in a new tab)

  3. First direct double-beta decay Q-value measurement of the neutrinoless double-beta decay candidate selenium-82 and development of a high-precision magnetometer

    … neutrino, the first direct double-beta decay Q-value measurement of the neutrinoless double-beta decay candidate 82Se was performed [D. L. Lincoln et al., Physical Review Letters 110, 012501 (2013)]. The measurement was carried out using Penning trap mass spectrometry, which has proven to be the …

    msu Repository record for First direct double-beta decay Q-value measurement of the neutrinoless double-beta decay candidate selenium-82 and development of a high-precision magnetometer (opens in a new tab)

  4. NEURAL NETWORK ARCHITECTURE DESIGN FOR MILITARY DECISION-MAKING UNDER FOG OF WAR

    … managing uncertainty. This thesis investigates Q-value functions implemented as deep neural networks to select the most promising action from a given state. Our approach trains Q-value approximators on perfect-information data to learn tactical decisions from observable features, then evaluates …

    nps Repository record for NEURAL NETWORK ARCHITECTURE DESIGN FOR MILITARY DECISION-MAKING UNDER FOG OF WAR (opens in a new tab)

  5. Level Studies of Some Mass 89 Nuclei

    … 2.567, 2.708, 2.770, 3.225 and 3.500 MeV. The Q value is 4.486 ± .012 Mev. </p> <p> The techniques of beta and gamma ray spectroscopy using Ge(Li), NaI(Tl) and plastic beta detectors have been applied in the study of the decay of 3.2 min. ⁸⁹Kr to levels in ⁸⁹Rb. Seventy nine of the one hundred …

    mcmaster Repository record for Level Studies of Some Mass 89 Nuclei (opens in a new tab)

  6. A high-precision mass measurement of 48Sc in support of neutrinoless double β-decay searches

    … 48Sc to determine the 48Ca single beta decay Q-value, which is relevant to double beta decay studies. A comprehensive evaluation of systematic effects influencing the measured cyclotron frequency ratio was performed, including contributions from magnetic field inhomogeneities, trap misalignment, …

    manitoba Repository record for A high-precision mass measurement of 48Sc in support of neutrinoless double β-decay searches (opens in a new tab)

  7. Precise determination of the 136Xe – 136Ba atomic mass difference and related mass differences in Ba and Cd

    … at the University of Manitoba. The Q-value for this difference was determined to be 2458.72(56) keV. The double-beta decay mode can be either neutrino (ββ2υ) or neutrinoless (ββ0υ), where the latter would be proof of the Majorana nature of neutrinos. A ββ0υ decay, which violates …

    manitoba Repository record for Precise determination of the 136Xe – 136Ba atomic mass difference and related mass differences in Ba and Cd (opens in a new tab)

  8. RF Tunable Resonators and Filters

    … tuning technique that maintains a constant Q value over a relatively wide tuning range. The traditional technique for tuning combline filters is achieved by changing the gap between the post and the tuning disk. Such a technique is known to yield a Q value that degrades considerably at the …

    waterloo Repository record for RF Tunable Resonators and Filters (opens in a new tab)

  9. The disintegration of neon by fast neutrons

    … observed, with 1% counting statistics. The Q,-value was measured as -0.77±0.08 Mev., in fair agreement with previously reported results. Careful search failed to reveal any evidence of excited states in O¹⁷. A level at 0.87 Mev. is known, and one at 1.6 Mev. is suspected, but calculation of …

    ubc Repository record for The disintegration of neon by fast neutrons (opens in a new tab) Download PDF for The disintegration of neon by fast neutrons (opens in a new tab)

  10. Mokslinių tyrimų ir eksperimentinės veiklos išlaidų poveikis Šiaurės Europos regiono įmonių vertei /

    … Thesis is to analyze the concept of company value and its relationship with the costs of Research and Development (R&D) activities in a theoretical aspect and to determine whether the costs Research and Development (R&D) activities affect the value of companies in the Northern European …

    vilnius Repository record for Mokslinių tyrimų ir eksperimentinės veiklos išlaidų poveikis Šiaurės Europos regiono įmonių vertei / (opens in a new tab)

  11. Effect of Particle Packing on Flow Property and Strength of Concrete Mortar

    … of the aggregate particles. (Generally, a high q value (>0.50) results in a coarse mixture, whereas a small q value (q<0.25) results in a mixture that is rich in fine particles.</p> <p>The study consists of two parts, as written of two research papers. In paper one, a fixed distribution modulus …

    iastate Repository record for Effect of Particle Packing on Flow Property and Strength of Concrete Mortar (opens in a new tab)

  12. Tobin's Q for Canadian firms

    Defined as the ratio of market value to replacement cost of tangible assets, Tobin's q is commonly used as a performance measure in research. Although the use of the q ratio is theoretically appealing, its empirical construction is subject to considerable measurement error. In this thesis, we …

    concordia Download PDF for Tobin's Q for Canadian firms (opens in a new tab)

  13. The association of prematurity and medical conditions with the gut microbiome of mammals

    … lambs, the anatomical site explained 54% (q-value=0.0004) of the variance in microbial beta diversity but that there was no significant effect of early-life nutritional supplementation on the microbial diversities of preterm lambs. However, prematurity per se explained 5.7% (q-value=0.024) of …

    auckland-ms Repository record for The association of prematurity and medical conditions with the gut microbiome of mammals (opens in a new tab)

  14. Nucleon transfer in heavy ion reactions

    … relate the incident energy to the reaction Q-value. The physical interpretation of the amplitude is discussed. In the case of proton transfer, the effect of Coulomb potential results in a shift of the binding energy of the proton. With this prescription we still obtain the same form of the …

    oxford Repository record for Nucleon transfer in heavy ion reactions (opens in a new tab)

  15. Radio Frequency Low Noise and High Q Integrated Filters in Digital CMOS Processes

    … is tunable from 80MHz to 110MHz, and the Q value is tunable from 0.5 to 28.9. 1 dB compression point is measured as -34.0dBm, combined with noise measurement results, a dynamic range of 54.1 dB results. Silicon area of the core circuit is 0.4 square millimeters. The center frequency of the …

    gatech Repository record for Radio Frequency Low Noise and High Q Integrated Filters in Digital CMOS Processes (opens in a new tab)

  16. Exploitation of nonlinear effects in micro-electromechanical resonators

    … using force feedback to increase the effective Q value of a MEMS resonator by partially cancelling the effects of viscous damping. Alternative methods to enhance the sensitivity of the resonator have been proposed in this thesis using the non-linear behaviour of the resonator which is known as …

    oxford Repository record for Exploitation of nonlinear effects in micro-electromechanical resonators (opens in a new tab)

  17. A Comparison of Methods Taking into Account Asymmetry when Evaluating Differential Expression in Gene Expression Experiments

    … compares three statistical methods (Modified Q-value, Modified SAM, and Asymmetric Local False Discovery Rate) used to identify differentially expressed (DE) genes that take into account such patterns while controlling false discovery rate (FDR). The results of the simulation studies performed …

    ndsu Repository record for A Comparison of Methods Taking into Account Asymmetry when Evaluating Differential Expression in Gene Expression Experiments (opens in a new tab)

  18. Thermal Neutron Capture Studies of Some Light Odd-Odd Nuclei

    … schemes are presented for these nuclei. The Q-values and gamma ray multiplicities have been obtained for the reactions studied. The average partial widths for primary Ml and El transitions have been calculated for the six nuclei and compared with the theoretical estimates. The features of the …

    mcmaster Repository record for Thermal Neutron Capture Studies of Some Light Odd-Odd Nuclei (opens in a new tab)

Page 1 of 7