Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 349 for “"Q- Factor"”.

  1. Automated Q-Factor Measurement Via a Network Analyzer

    … unloaded resonant frequency fo, the unloaded Q-factor Qo, and the coupling coefficient β. The input reflection coefficient of the resonator is measured via the network analyzer, which is driven by an HP desk computer. The graphical techniques (Smith Chart) are replaced by the much faster …

    ucf Repository record for Automated Q-Factor Measurement Via a Network Analyzer (opens in a new tab)

  2. Q Factor in cycling: kinematic and physiological effects

    Q Factor represents the horizontal distance between pedals on a bicycle, measured from the outside edge of each crankarm. The action of pedalling is based upon human gait, which utilises a step width lower than standard Q Factors (150mm for road bicycles). The aims of this thesis were to understand …

    birmingham Download PDF for Q Factor in cycling: kinematic and physiological effects (opens in a new tab)

  3. EFFECTS OF INCREASED Q-FACTOR ON KNEE BIOMECHANICS DURING CYCLING

    <p>Q-Factor (QF), the inter-pedal width, in cycling is the analog to step-width in gait. Increased step-width has been shown to reduce peak knee abduction moment (KabM), however no studies have examined the frontal plane biomechanics with increased QF in cycling. <strong>Purpose:</strong> The …

    ut-knoxville Repository record for EFFECTS OF INCREASED Q-FACTOR ON KNEE BIOMECHANICS DURING CYCLING (opens in a new tab)

  4. Correlating Q-Factor Measurements to Other Parameters in Deteriorated Concrete

    … deterioration can be quantified through the Q-factor, little is known about its relationship to other parameters. This research study explored possible correlations between Q-factors and other parameters including expansion change, weight change, and compression strength in deteriorated …

    maryland Repository record for Correlating Q-Factor Measurements to Other Parameters in Deteriorated Concrete (opens in a new tab)

  5. Low Q-factor Silicon Photonic Cavities for Optical Filtering and Single-Photon Detection

    … in a linear cascade of three rings. This low Q-factor filtering approach promises to suppress the build up of electric field intensity inside the critically coupled resonators, preventing spurious non-linear effects such as single-photon generation within the cavity. The advantages and …

    bristol Repository record for Low Q-factor Silicon Photonic Cavities for Optical Filtering and Single-Photon Detection (opens in a new tab) Download PDF for Low Q-factor Silicon Photonic Cavities for Optical Filtering and Single-Photon Detection (opens in a new tab)

  6. Effects of Small and Normalized Q-Factor Changes and Knee Alignment on Knee Biomechanics During Stationary Cycling

    <p>Increasing inter-pedal distance (Q-Factor; QF) in cycling increases peak internal knee abduction moments (KAbM). The effect of smaller, normalized changes in QF has not been investigated, and the effect of static knee alignment at varying QFs is unknown. Purpose: The primary purpose of this …

    ut-knoxville Repository record for Effects of Small and Normalized Q-Factor Changes and Knee Alignment on Knee Biomechanics During Stationary Cycling (opens in a new tab)

  7. Enhanced Second Harmonic Generation in Dual-Resonance 3R-MoS2 Metasurfaces, Roles of the Q Factor and Absorptance

    … scale with the square of the resonance quality factor (Q^2). However, experiments show that samples with similar Q values can exhibit very different SHG outputs, indicating that, for the sample-to-sample variations studied here, pump absorptance also plays an important role in determining the …

    anu Repository record for Enhanced Second Harmonic Generation in Dual-Resonance 3R-MoS2 Metasurfaces, Roles of the Q Factor and Absorptance (opens in a new tab)

  8. Acoustic resonators with integrated microfluidic channels for ultra-high Q-factor: a new paradigm for in-liquid gravimetric detection

    … (POC) applications. However, the quality factor (Q-factor) of acoustic biosensors is often low, limiting their sensitivity and accuracy in terms of in-liquid gravimetric detection for biosensing applications. In this dissertation, we present a novel approach that eliminates nearly all …

    duke Repository record for Acoustic resonators with integrated microfluidic channels for ultra-high Q-factor: a new paradigm for in-liquid gravimetric detection (opens in a new tab)

  9. Precise measurements of surface resistance of high temperature superconducting thin films using a novel method of Q-factor computations for sapphire dielectric resonators in the transmission mode

    … can store microwave energy. The unloaded quality factor Q₀ of the structure measured typically in the transmission mode and is used for calculations of the surface resistance. While there is a need for accurate procedures to measure the surface resistance, no standard procedure has yet been …

    jamescook Download PDF for Precise measurements of surface resistance of high temperature superconducting thin films using a novel method of Q-factor computations for sapphire dielectric resonators in the transmission mode (opens in a new tab)

  10. Frequency and Damping Noise of Atomic Force Microscopy Cantilevers with Optomechanically Modified Quality Factor at Low Temperature

    … and optically induced force, the quality (Q) factor and resonant frequency are both dependent on the optical cavity length (formed by the fiber-cantilever distance). A systematic experimental study was undertaken to determine the influence of optomechanically enhanced Q factor on frequency …

    texas-state Repository record for Frequency and Damping Noise of Atomic Force Microscopy Cantilevers with Optomechanically Modified Quality Factor at Low Temperature (opens in a new tab)

  11. Measurement of the Quality Factor for the Micro Electromechanical System Cantilever Devices by Using Non-Destructive Test Methodology

    … to determine performance criteria such as Q-factor. With regards to reliability and Q-factor; stiction, noise and squeeze film damping are the important occurrences thereby, this report provides very brief general information about these subjects that is to say detailed examination of these …

    waterloo Repository record for Measurement of the Quality Factor for the Micro Electromechanical System Cantilever Devices by Using Non-Destructive Test Methodology (opens in a new tab)

  12. The effects of natural aging, stress relief & ferritic nitrocarburizing treatment on the damping development of ventilated grey cast iron brake discs

    This report investigates the change in Q-factor that ventilated grey cast iron brake discs with different treatments applied experience over time to analyse the impact of natural aging, stress relief treatment and ferritic nitrocarburizing treatment (FNC). Eighty grey cast iron brake discs in …

    chalmers Repository record for The effects of natural aging, stress relief & ferritic nitrocarburizing treatment on the damping development of ventilated grey cast iron brake discs (opens in a new tab)

  13. OPTIMIZATION AND CONTROL OF AN ARRAY OF WAVE ENERGY CONVERTERS

    … with a given optimal layout, and a higher q-factor was achieved. Both impedance matching optimal control and derivative control were employed, which provides both theoretical maximum energy and a more realistic case. Then the work was expanded to optimization of both the array layout and the …

    mtu Repository record for OPTIMIZATION AND CONTROL OF AN ARRAY OF WAVE ENERGY CONVERTERS (opens in a new tab)

  14. STIMULATED RAMAN SCATTERING IN MICRO SPHERE RESONATORS

    … compared to theoretical analysis to obtain the Q-factor of the resonator. The correspondence of the Q-factor on the coupling condition and the degradation of the Q factor over time are further discussed. SRS in silica micro sphere resonators is demonstrated with a reduced threshold power as low as …

    clemson Repository record for STIMULATED RAMAN SCATTERING IN MICRO SPHERE RESONATORS (opens in a new tab)

  15. DESIGN, SIMULATION AND OPTIMIZATION OF HIGH Q RF SPIRAL INDUCTORS ON SILICON CHIPS

    … works done to find many methods to improve the Q factor, the optimization of the spiral inductors is a never end job, and there is a continually great incentive to design, optimize, and model spiral inductors fabricated on Si substrates. Our project firstly researches on the design and …

    nus Repository record for DESIGN, SIMULATION AND OPTIMIZATION OF HIGH Q RF SPIRAL INDUCTORS ON SILICON CHIPS (opens in a new tab) Download file for DESIGN, SIMULATION AND OPTIMIZATION OF HIGH Q RF SPIRAL INDUCTORS ON SILICON CHIPS (opens in a new tab)

  16. Performance Limits for Microstrip Patch Antennas

    … for three key metrics in this thesis, Q-factor (which is inversely proportional to bandwidth), radiation efficiency, and gain. Limits on these metrics provide insights into the maximum achievable performance for these antennas, guiding the design process beyond traditional optimization …

    lund Repository record for Performance Limits for Microstrip Patch Antennas (opens in a new tab) Download PDF for Performance Limits for Microstrip Patch Antennas (opens in a new tab)

Page 1 of 18