Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 172 for “"Q-Value"”

  1. Policy Extraction via Online Q-Value Distillation

    … rules that transparently reconstruct the value function for all possible states. It convincingly beats performance benchmarks provided by earlier policy distillation methods resulting in performance closest to the original Deep Learning policy.

    waterloo Repository record for Policy Extraction via Online Q-Value Distillation (opens in a new tab)

  2. Identification of Differentially Expressed Genes and Gene Sets Using a Modified Q-Value

    … paper compares a recently proposed modified q-value method that takes into account such patterns to a traditional q-value method for experiments with three treatments. The results of simulation studies performed suggest that the proposed methods improve upon the traditional method in the …

    ndsu Repository record for Identification of Differentially Expressed Genes and Gene Sets Using a Modified Q-Value (opens in a new tab)

  3. High-precision Penning-trap determination of the electron capture Q-value in 163-Ho for the determination of the electron neutrino mass

    … sensitivity level of those experiments, the Q-value of this decay from microcalorimetry is compared to an independently measured one. This cumulative thesis is based on the experimental developments towards and the independent measurement of the Q-value of 163-Ho electron capture using …

    heid-diss Repository record for High-precision Penning-trap determination of the electron capture Q-value in 163-Ho for the determination of the electron neutrino mass (opens in a new tab)

  4. High-precision Q-value and mass measurements for neutrino physics with TRIGA-TRAP and commissioning of an on-line ion source for TRIGA-SPEC

    Der Nachweis des neutrinolosen doppelten Elektroneneinfangs kann zum Beweis des Majoranacharakters von Neutrinos verwendet werden. Übergänge mit einer Energieentartung zwischen dem Anfangs- und dem Endzustand weisen eine resonante Verstärkung der Zerfallsrate auf, so dass diese besonders für …

    heid-diss Repository record for High-precision Q-value and mass measurements for neutrino physics with TRIGA-TRAP and commissioning of an on-line ion source for TRIGA-SPEC (opens in a new tab)

  5. First direct double-beta decay Q-value measurement of the neutrinoless double-beta decay candidate selenium-82 and development of a high-precision magnetometer

    … neutrino, the first direct double-beta decay Q-value measurement of the neutrinoless double-beta decay candidate 82Se was performed [D. L. Lincoln et al., Physical Review Letters 110, 012501 (2013)]. The measurement was carried out using Penning trap mass spectrometry, which has proven to be the …

    msu Repository record for First direct double-beta decay Q-value measurement of the neutrinoless double-beta decay candidate selenium-82 and development of a high-precision magnetometer (opens in a new tab)

  6. Charge-breeding studies for high-precision mass measurements on short-lived nuclides at TITAN and a direct determination of the 51Cr electron-capture Q-value for neutrino physics

    … physics. This work provides the result of a Q-value (mass difference) measurement of the ⁵¹Cr(e,𝜈e)⁵¹V reaction. This first direct Q-value measurement confirmed the neutrino energies that were used in calculations for the solar neutrino experiments SAGE and GALLEX and the so-called gallium. …

    ubc Repository record for Charge-breeding studies for high-precision mass measurements on short-lived nuclides at TITAN and a direct determination of the 51Cr electron-capture Q-value for neutrino physics (opens in a new tab)

  7. The First Direct Q_EC Measurement in 163Ho and the Development of the High-Precision Mass Spectrometer PENTATRAP for Neutrino Physics

    … errors an independent measurement of the Q-value of the EC in 163Ho is required. For the first phase of ECHo the issue with the discrepancy between the latest microcalorimetry measurements of the Q-value and its literature value needed to be fixed. For this, a first direct measurement of the …

    heid-diss Repository record for The First Direct Q_EC Measurement in 163Ho and the Development of the High-Precision Mass Spectrometer PENTATRAP for Neutrino Physics (opens in a new tab)

  8. NEURAL NETWORK ARCHITECTURE DESIGN FOR MILITARY DECISION-MAKING UNDER FOG OF WAR

    … managing uncertainty. This thesis investigates Q-value functions implemented as deep neural networks to select the most promising action from a given state. Our approach trains Q-value approximators on perfect-information data to learn tactical decisions from observable features, then evaluates …

    nps Repository record for NEURAL NETWORK ARCHITECTURE DESIGN FOR MILITARY DECISION-MAKING UNDER FOG OF WAR (opens in a new tab)

  9. Design of deep Q-networks for transfer time prediction of spacecraft orbit-raising

    … used in trajectory planning, relies on a Q-value. In the electric orbit-raising problem under consideration in this thesis, this Q-Value requires computation of transfer time in near real-time to have practical DRL training times. In our work, this Q-value is predicted by a set of deep …

    ksu Repository record for Design of deep Q-networks for transfer time prediction of spacecraft orbit-raising (opens in a new tab)

  10. Modeling Mutual Influence in Multi-Agent Reinforcement Learning

    … policies. Each agent shapes the individual Q-value by marginalizing the conditional policies in the joint Q-value and finding the best response to improving their policies. I further extend PR2 to Generalized Recursive Reasoning (GR2) with different hierarchical levels of rationality. GR2 …

    ucl Repository record for Modeling Mutual Influence in Multi-Agent Reinforcement Learning (opens in a new tab)

  11. Level Studies of Some Mass 89 Nuclei

    … 2.567, 2.708, 2.770, 3.225 and 3.500 MeV. The Q value is 4.486 ± .012 Mev. </p> <p> The techniques of beta and gamma ray spectroscopy using Ge(Li), NaI(Tl) and plastic beta detectors have been applied in the study of the decay of 3.2 min. ⁸⁹Kr to levels in ⁸⁹Rb. Seventy nine of the one hundred …

    mcmaster Repository record for Level Studies of Some Mass 89 Nuclei (opens in a new tab)

  12. A high-precision mass measurement of 48Sc in support of neutrinoless double β-decay searches

    … 48Sc to determine the 48Ca single beta decay Q-value, which is relevant to double beta decay studies. A comprehensive evaluation of systematic effects influencing the measured cyclotron frequency ratio was performed, including contributions from magnetic field inhomogeneities, trap misalignment, …

    manitoba Repository record for A high-precision mass measurement of 48Sc in support of neutrinoless double β-decay searches (opens in a new tab)

  13. Precise determination of the 136Xe – 136Ba atomic mass difference and related mass differences in Ba and Cd

    … at the University of Manitoba. The Q-value for this difference was determined to be 2458.72(56) keV. The double-beta decay mode can be either neutrino (ββ2υ) or neutrinoless (ββ0υ), where the latter would be proof of the Majorana nature of neutrinos. A ββ0υ decay, which violates …

    manitoba Repository record for Precise determination of the 136Xe – 136Ba atomic mass difference and related mass differences in Ba and Cd (opens in a new tab)

  14. RF Tunable Resonators and Filters

    … tuning technique that maintains a constant Q value over a relatively wide tuning range. The traditional technique for tuning combline filters is achieved by changing the gap between the post and the tuning disk. Such a technique is known to yield a Q value that degrades considerably at the …

    waterloo Repository record for RF Tunable Resonators and Filters (opens in a new tab)

  15. Ab initio calculations of the electron capture spectrum in 163Ho

    … data and the totally released energy, or Q-value, is deter-mined using Bayesian parameter estimation. A different approach to determineQisPenning-trap mass-spectroscopy. There, the mass difference between ionized motherand daughter atom is measured, which needs to be corrected for binding …

    heid-diss Repository record for Ab initio calculations of the electron capture spectrum in 163Ho (opens in a new tab)

  16. The disintegration of neon by fast neutrons

    … observed, with 1% counting statistics. The Q,-value was measured as -0.77±0.08 Mev., in fair agreement with previously reported results. Careful search failed to reveal any evidence of excited states in O¹⁷. A level at 0.87 Mev. is known, and one at 1.6 Mev. is suspected, but calculation of …

    ubc Repository record for The disintegration of neon by fast neutrons (opens in a new tab)

  17. Mokslinių tyrimų ir eksperimentinės veiklos išlaidų poveikis Šiaurės Europos regiono įmonių vertei /

    … Thesis is to analyze the concept of company value and its relationship with the costs of Research and Development (R&D) activities in a theoretical aspect and to determine whether the costs Research and Development (R&D) activities affect the value of companies in the Northern European …

    vilnius Repository record for Mokslinių tyrimų ir eksperimentinės veiklos išlaidų poveikis Šiaurės Europos regiono įmonių vertei / (opens in a new tab)

  18. Effect of Particle Packing on Flow Property and Strength of Concrete Mortar

    … of the aggregate particles. (Generally, a high q value (>0.50) results in a coarse mixture, whereas a small q value (q<0.25) results in a mixture that is rich in fine particles.</p> <p>The study consists of two parts, as written of two research papers. In paper one, a fixed distribution modulus …

    iastate Repository record for Effect of Particle Packing on Flow Property and Strength of Concrete Mortar (opens in a new tab)

  19. Tobin's Q for Canadian firms

    Defined as the ratio of market value to replacement cost of tangible assets, Tobin's q is commonly used as a performance measure in research. Although the use of the q ratio is theoretically appealing, its empirical construction is subject to considerable measurement error. In this thesis, we …

    concordia

Page 1 of 9