Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 5 of 5 for “"QNFT"”

  1. Comparison of Condensation Nuclei Counter and Controlled Negative Pressure Methods under Different Environmental Conditions Tested with a Mannequin and Human Subjects

    … regarding respirators. Quantitative fit testing (QNFT) is a critical component of an OSHA compliant respiratory protection program. QNFTs are often performed in environments where temperature and relative humidity (RH) vary. However, no study has investigated the possible effects of these …

    wvu Repository record for Comparison of Condensation Nuclei Counter and Controlled Negative Pressure Methods under Different Environmental Conditions Tested with a Mannequin and Human Subjects (opens in a new tab)

  2. Enhancing Performance of Respirators through Design Evaluation and Novel Monitoring Techniques

    … the aerosol-based quantitative fit testing (QNFT) is primarily conducted by condensation particle counting (CPC) method, the optical particle counting (OPC) method has also shown to be effective for QNFT. However, the humidity within the sampling tube could influence the accuracy of particle …

    ohiolink Repository record for Enhancing Performance of Respirators through Design Evaluation and Novel Monitoring Techniques (opens in a new tab)

  3. Evaluation of the QuantiFit2™ compared to the PortaCount™ Pro+ for respirator fit testing in a firefighter population: a performance and user preference study

    … of two OSHA-approved quantitative fit testing (QNFT) devices: the PortaCount™ Pro+, that uses condensation nuclei counting (CNC) technology, and the QuantiFit2™, which uses controlled negative pressure (CNP) technology, in a firefighter population. Limited research exists comparing both …

    colostate Repository record for Evaluation of the QuantiFit2™ compared to the PortaCount™ Pro+ for respirator fit testing in a firefighter population: a performance and user preference study (opens in a new tab)

  4. Oxygen and Carbon Dioxide Levels During Qualitative Respirator Fit Testing

    Approved Occupational Safety and Health Administration qualitative respirator fit test methods require the use of a test hood about the subject’s head and shoulders. Workers fit tested by this method have commented on the discomfort of being inside the test enclosure. This study was designed to …

    ohiolink Repository record for Oxygen and Carbon Dioxide Levels During Qualitative Respirator Fit Testing (opens in a new tab)

  5. Respiratory fit testing: a comparative study on the AeroFit® vs. the Portacount™ Pro Plus

    Respirator fit testing is a critical component of respiratory protection programs and is required to ensure that respirators provide adequate protection in accordance with Occupational Safety and Health Administration (OSHA) standards (29 CFR 1910.134). This study focused on quantitative …

    colostate Repository record for Respiratory fit testing: a comparative study on the AeroFit® vs. the Portacount™ Pro Plus (opens in a new tab)