Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 46 for “"QRS Detection"”.
-
Baseline Wander Removal and QRS Detection Using Holter ECG Signals
… a new RPeak Filter and possibly an improved QRS detection scheme. Each of the tasks presented in the problem statement, baseline wander removal [6-12] and QRS detection [13-18] algorithms have been addressed previously. In the present commercial system, produced by Biomedical Systems (BMS), …
-
Computationally Efficient QRS Detection Analysis In Electrocardiogram Based On Dual-Slope Method
… monitoring sensors. A computationally efficient QRS detection algorithm is indispensable for low power operation on electrocardiogram (ECG) signal. In need of detecting QRS complex, most of the early works were proposed based on derivatives of ECG signal. They can be easily implemented with high …
-
ΑΥΤΟΜΑΤΗ ΕΠΕΞΕΡΓΑΣΙΑ ΗΛΕΚΤΡΟΚΑΡΔΙΟΓΡΑΦΗΜΑΤΟΣ. ΕΦΑΡΜΟΓΗ ΤΕΧΝΙΚΩΝ ΤΕΧΝΟΛΟΓΙΑΣ ΓΝΩΣΗΣ
… WITH CERTAIN ADVANTAGES. 2) THE DEVELOPMENT OF QRS DETECTION ALGORITHM USING CLUSTER ANALYSIS. 3) THE DEVELOPMENT OF A QRS DETECTION ALGORITHM USING TIME RECURSIVE PREDICTION TECHNIQUES. 4) THE DEVELOPMENT OF A QRS DETECTION ALGORITHM USING A HYBRID APPROACH. 5) THE DEVELOPMENT OF A QRS …
-
Real-Time ECG Analysis Using DSP Techniques
… computations such as heart rate measurements and QRS duration measurement. In this work, the author developed two real-time detection algorithms. A QRS detection and heart rate measurement algorithm (qrs _ detect. m) and an ECG classification and QRS duration measurement algorithm (qrs_duration.m) …
-
Beneath the surface electrocardiogram: computer algorithms for the non-invasive assessment of cardiac electrophysiology
… cardiac electrophysiology. The P wave and the QRS complex of the ECG respectively depict atrial and ventricular depolarization. QRS detection is a pre-requisite to P wave and QRS averaging. A novel algorithm for robust QRS detection in mice achieves a four-fold reduction in false detections …
-
Computerised Detection and Classification of Five Cardiac Conditions
… recognition comprise: signal pre-processing, QRS detection, feature extraction and neural network for signal classification. In this project, signal processing and neural network toolbox will be used in Matlab environment. The processed signal source came from the Massachusetts Institute of …
-
A Novel Smart Wearable System with Edge Computing AI for Cardiac Disease Detection and Continuous Monitoring
… pathologies can advance to severe stages before detection. Moreover, motion and posture variability degrade real-life monitoring continuity, and without on-device edge computing, wearables must rely on post-processing that impedes true real-time detection. We have designed a multimodal wearable …
-
Feasibility of subcutaneous ECG leads for synchronized timing of a counterpulsation device.
… that subcutaneous ECG leads provide equivalent QRS detection, lead migration, and durability as clinical-standard epicardial leads. Methods: Two epicardial and six subcutaneous leads were implanted in bovine (7 days, n=4 and 14 days, n=2). Epicardial and subcutaneous ECGs were recorded …
-
A miniature Microcontroller-Based Electrocardiographic Patient Monitoring Device Using Telemetry
… the signal in real-time using a robust QRS detection algorithm. A dual tone multifrequency tone (DTMF) is generated by the microcontroller after a valid QRS complex is detected. A DTMF tone consists of two low frequency sine waves which are added together. Different tones are generated …
-
Rr Interval Estimation From An Ecg Using A Linear Discrete Kalman Filter
… data obtained must be good and reliable. Most QRS detection algorithms can easily miss a QRS pulse producing unreliable RR interval values. Therefore it is necessary to estimate the RR interval in the presence of missing QRS beats. The approach in this thesis is to apply KALMAN estimation …
-
Energy-Efficient ECG Signal Compression Method in Wearable Body Sensor Networks by Leveraging Empirical Mode Decomposition
… distortion perspective, our method achieves high QRS detection performance with the sensitivity (SE) of 99.8% and the specificity (SP) of 99.6%, which shows that our ECG compression method can preserve almost all the QRS features and have no impact on the diagnosis process. In addition, the energy …
-
Low Power Circuits for Smart Flexible ECG Sensors
… of the ECG sensor i.e., analog frontend (AFE), QRS detector, and cardiac arrhythmia classifier (CAC), are studied in this research. A fully differential difference amplifier (FDDA) based AFE that employs DC-coupled input stage increases the input impedance and improves CMRR. A parasitic …
-
Design and implementation of ultra-low-power sensor interface circuits for ECG acquisition
… is measured to be 445 nW in the minimum band QRS detection mode, and 895 nW in the full band ECG acquisition mode. A miniature ECG plaster prototype based on the sensor interface chip and a commercial ZigBee transceiver is thereafter demonstrated. The captured ECG data are either stored …
-
Intelligent Pattern Analysis of the Foetal Electrocardiogram
… ECG pattern analysis. The signal enhancement, QRS detection and pattern recognition of important ECG waveform shapes have had extensive testing and results are presented. Results show that no significant loss of information is incurred as a result of the signal enhancement and feature …
-
Digital signal processing and artificial intelligence for the automated classification of food allergy
… results were, however, obtained with manual QRS annotations, and these are not a viable methodology for real-time diagnostic applications. Even so, this was the first work which has categorically correlated changes in HRV features to the onset of allergic events, and manual annotations yield …
-
BIOMETRIC IDENTIFICATION USING ELECTROCARDIOGRAM AND TIME FREQUENCY FEATURE MATCHING
… In addition, we proposed a methodology for QRS detection and segmentation using STFT and binary classification of ECG fiducial features. In the second paper, we proposed a technique for choosing overlapped data windows to extract the abovementioned features. Namely, the dynamic change in the …
-
Vícesvodová rozhodovací pravidla v detekci komplexů QRS
QRS komplex je nejvýraznější složkou EKG signálu. Detekce QRS komplexu je prvním krokem k analýze EKG signálu. Slouží jako výchozí bod k rozměření celého signálu. V této práci je realizován detektor založený na jednosvodové detekci a detektor založený na vícesvodové detekci. Oba detektory jsou …
-
Software pro hodnocení detektorů QRS komplexů
QRS komplex je nejvýraznější element vyskytující se v EKG signálu. Díky svým vlastnostem je využíván při určování tepové frekvence a slouží jako jeden z referenčních bodů při automatickém rozměření EKG. Proto je důležité, aby byla jeho detekce co nejpřesnější. Tato práce je zaměřena na vytvoření …
-
Monitorování EKG signálu v reálném čase
… prvkom pri analyzovaní EKG signálu je detekcia QRS komplexov. QRS komplexy sú najvýraznejšia zložka signálu. V tejto práci je zahrnutý stručný prehľad metód detekcie QRS komplexov v reálnom čase. Na základe rešerše je vybraný vhodný detekčný algoritmus, ktorý je realizovaný v programovom …
Page 1 of 3