Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 200 for “"QUALITY FACTOR Q"”.

  1. Geologically and well-log constrained quality factor (Q) analysis for seismic reservoir characterization.

    Measurements of P- and S-wave velocities are conducted on alternating layers of acrylic and aluminum. In this experiment, both thickness of the layers, and frequency of the propagating wave are varied. Based on these observations, for wavelength/thickness (lambda/d) >> 1, the medium behaves as a …

    oklahoma-thes Repository record for Geologically and well-log constrained quality factor (Q) analysis for seismic reservoir characterization. (opens in a new tab)

  2. Estratégia de inversão do fator Q sísmico via modelagem convolucional não-estacionária

    Estimating the seismic quality factor Q is an important problem in seismic processing, since attenuation directly affects the amplitude, phase, and resolution of the propagated signal. Classical Q-estimation methods are generally better suited for VSP data and usually treat attenuation separately …

    brazil-ufrn Repository record for Estratégia de inversão do fator Q sísmico via modelagem convolucional não-estacionária (opens in a new tab)

  3. The influence of physical system parameters on the performance of adaptive filters for system identification of mechanical systems

    … systems for a given input. The effects of quality factor (Q), dispersion and transmission time on adaptive filter performance were investigated. Optimal filter delay times and tap weight vector lengths were determined.

    nps Repository record for The influence of physical system parameters on the performance of adaptive filters for system identification of mechanical systems (opens in a new tab)

  4. Enhanced Second Harmonic Generation in Dual-Resonance 3R-MoS2 Metasurfaces, Roles of the Q Factor and Absorptance

    … to scale with the square of the resonance quality factor (Q^2). However, experiments show that samples with similar Q values can exhibit very different SHG outputs, indicating that, for the sample-to-sample variations studied here, pump absorptance also plays an important role in …

    anu Repository record for Enhanced Second Harmonic Generation in Dual-Resonance 3R-MoS2 Metasurfaces, Roles of the Q Factor and Absorptance (opens in a new tab)

  5. Local signal regularity and smoothness as a means for seismic Q estimation

    … between the Lipschitz exponent and seismic quality factor Q is obtained. However, analysing the smoothness parameter results in an invertible power law relation between the aforementioned parameter and Q. Applying the non-linear MHZ model to the Ross Lake VSP field data captures the general …

    calgary Repository record for Local signal regularity and smoothness as a means for seismic Q estimation (opens in a new tab)

  6. Constraining the Radial Structure of Seismic Attenuation using Multiple S-Wave Datasets

    Seismic attenuation, quantified by the quality factor Q, provides crucial constraints on Earth's thermal and chemical structure due to its strong sensitivity to temperature and presence of volatiles. This study investigates the radial Q structure of Earth's mantle using amplitude measurements from …

    vt Repository record for Constraining the Radial Structure of Seismic Attenuation using Multiple S-Wave Datasets (opens in a new tab)

  7. Lithium niobate resonators for piezoelectric power conversion

    … good conversion efficiency, thanks to their high quality factor (Q) and electromechanical coupling (kₜ²). However, the converter output power range is limited by large spurious modes near resonance. This report will describe two designs for near-spurious-free or spurious-free lithium niobate …

    texas Repository record for Lithium niobate resonators for piezoelectric power conversion (opens in a new tab)

  8. Q Improvement of a 5.2 GHz TE<sub>011</sub> Cavity by Incorporating Y<sub>1</sub>Ba<sub>2</sub>Cu<sub>3</sub>O<sub>7-x</sub>

    … superconducting material to improve the quality factor (Q) of a 5.2 GHz cylindrical resonant cavity. In particular, the approach is to electrophoretically deposit polycrystalline Y1Ba2Cu3O7-x (YBCO) on the conducting surface of the cavity cylinder. Spalling of the YBCO ceramic coating due …

    odu Repository record for Q Improvement of a 5.2 GHz TE<sub>011</sub> Cavity by Incorporating Y<sub>1</sub>Ba<sub>2</sub>Cu<sub>3</sub>O<sub>7-x</sub> (opens in a new tab)

  9. Investigation of thermoacoustic muffler

    … is characterized by its ability to reduce the quality factor Q of an acoustic resonator. Measurement of the Q of a helium filler muffler were made for temperature differences ranging from 0 to -130 degrees C. The measured Q-reduction, approximately 30%, agrees with predicted reductions. The …

    nps Repository record for Investigation of thermoacoustic muffler (opens in a new tab)

  10. Attenuation tomography of the upper inner core

    … than 5.8. t* parameter is directly related to quality factor Q { measure of attenuation in the medium. We first perform a linearised inversion in which we assume that the logarithm of inverse quality factor Q is normally distributed. We connect the least-squares method with probabilistic …

    anu Repository record for Attenuation tomography of the upper inner core (opens in a new tab)

  11. Design and Implementation of a Z-Axis MEMS Gyroscope with a Symmetric Multiple-Mass Mechanical Structure

    … multiple-mass design prioritizes the sense-mode Quality Factor (Q) and thus improves its scale factor. The proposed mechanically coupled, dynamically balanced anti-phase sense-mode design minimizes energy dissipation through the substrate in order to maximize the Q. Numerical simulation is …

    odu Repository record for Design and Implementation of a Z-Axis MEMS Gyroscope with a Symmetric Multiple-Mass Mechanical Structure (opens in a new tab)

  12. On-chip self-rolled-up nanomembrane tube inductor for RFIC performance enhancement

    … of the planar spiral inductors, with excellent quality factor (Q) and much higher operating frequency than the 2D counterparts in both capabilities.

    uiuc Repository record for On-chip self-rolled-up nanomembrane tube inductor for RFIC performance enhancement (opens in a new tab)

  13. An Investigation Of Seismic Attenuation In Marine Sediments

    … propagating pulse have a low-pass effect. The quality factor, Q, was measured in two case studies. In the first, the mean Q was determined from wavelet and spectrum modelling and found to be 60 for fine sands and 47 for coarse sands in the 1 kHz to 3 kHz frequency band. In the second, Q was …

    plymouth Repository record for An Investigation Of Seismic Attenuation In Marine Sediments (opens in a new tab)

  14. Piezo-on-Silicon Microelectromechanical Resonators

    … order length extensional bulk modes with high quality factor (Q). Measurement results are in good agreement with the developed ANSYS simulations.

    gatech Repository record for Piezo-on-Silicon Microelectromechanical Resonators (opens in a new tab)

  15. Microelectromechanical Sensors And Measurements

    … thereby suggesting a means of improving the quality factor (Q) of resonance in fluid. The non-linear frequency dependence to stress in a buckled beam is used to demonstrate a sensitive generic geometry for trace vapor sensing. In the fundamental study of quality factor, the …

    cornell Repository record for Microelectromechanical Sensors And Measurements (opens in a new tab)

  16. Design Guide for CMOS Process On-Chip 3D Inductor using Thru-Wafer Vias

    … was used to measure all devices. The highest quality factor (Q) measured was 11.25 at 798MHz for a 1-turn device with a self-resonant frequency (fsr) of 4.4GHz. The largest inductance (L) measured was 45nH on a 20-turn wide trace device with a maximum Q of 4.25 at 732MHz. A 40% reduction in …

    boise Repository record for Design Guide for CMOS Process On-Chip 3D Inductor using Thru-Wafer Vias (opens in a new tab)

  17. A novel, multiple-electrode penning trap

    … for protons in the harmonic well. The harmonic quality factor $Q$ = $f$/$\Delta f$ is observed to be 120. Systematic uncertainties allow for agreement of the observed capture efficiency with the expected 100%, although future work will be necessary. Possible future improvements to the system, …

    rice Repository record for A novel, multiple-electrode penning trap (opens in a new tab)

  18. Zero DC offset active RC filter designs.

    … values for critical frequency ù 0 and filter quality factor Q. Filter schematics are captured and their frequency responses are simulated using circuit simulation software. Sample filters are built and their frequency responses are confirmed using a network analyzer. Extension to higher order …

    louisville Repository record for Zero DC offset active RC filter designs. (opens in a new tab)

Page 1 of 10