Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 12 of 12 for “"Quadrature Detection"”

  1. Digital In-phase and Quadrature Detection Techniques

    … implementing two different approaches to digital quadrature detection for use in coherent MTI (moving target indicator) radar systems. The purpose of quadrature detection for MTI radar and the advantages of digital detection techniques are discussed. Sampling and analog-to-digital conversion noise …

    ucf Repository record for Digital In-phase and Quadrature Detection Techniques (opens in a new tab)

  2. Low frequency Quadrature detector design, simulation and implementation for use in underground communication

    … This thesis investigates the design of a compact quadrature sampling detector for extremely low frequency through the earth communication. It is hoped that a receiver such as that designed herein could receive signals at frequencies much much less than 10 kHz through the earth. Furthermore, this …

    wvu Repository record for Low frequency Quadrature detector design, simulation and implementation for use in underground communication (opens in a new tab)

  3. Application Of Antenna Synthesis And Digital Signal Processing Techniques For Active Millimeter-wave Imaging Systems

    … heterodyne receivers with digital in-phase and quadrature detection. Signal correlation is performed using the digitized data, which is stored for post-processing, electronic focusing, and image reconstruction. Near-field imaging using interferometric reconstructions is achieved using electronic …

    ucf Repository record for Application Of Antenna Synthesis And Digital Signal Processing Techniques For Active Millimeter-wave Imaging Systems (opens in a new tab)

  4. Implementation of a X-mode multichannel edge density profile reflectometer for the new ICRH antenna on ASDEX Upgrade

    … This diagnostic uses a coherent heterodyne quadrature detection architecture and probes the plasma in the range 40-68 GHz to measure plasma edge electron densities up to 2×1019 m-3, with magnetic fields between 1.85 T and 2.7 T, and a repetition interval as low as 25 μs. This work details …

    ghent Repository record for Implementation of a X-mode multichannel edge density profile reflectometer for the new ICRH antenna on ASDEX Upgrade (opens in a new tab)

  5. Mechatronic Design, Dynamics, Controls, and Metrology of a Long-Stroke Linear Nano-Positioner

    … and without a compensation scheme for encoder quadrature detection errors. The compensation is observed to reduce the ±45 [nm] control error to ±15 [nm]. For the assessment of stage performance and the verification of design choices, modal testing and laser interferometric metrology have been …

    waterloo Repository record for Mechatronic Design, Dynamics, Controls, and Metrology of a Long-Stroke Linear Nano-Positioner (opens in a new tab)

  6. Development of an all-optical non-contact label-free absorption microscopy system based on quadrature interferometry

    … called Absorbance Mach–Zehnder Interferometric Quadrature (AMAZE-IQ or AMAZE for simplicity) microscopy. Similar to PARS, AMAZE uses two co-focused laser beams: a pulsed laser for excitation and a continuous wave (CW) laser for interrogation. However, unlike PARS, AMAZE leverages the sensitivity …

    alberta Repository record for Development of an all-optical non-contact label-free absorption microscopy system based on quadrature interferometry (opens in a new tab)

  7. Phase-locked Fourier domain optical coherence tomography

    … and thus reduces the sensitivity for flow detection. However, information on flow is especially interesting in ophthalmology since several studies of retinal blood flow – using laser Doppler flowmetry – have already outlined that vessel flow properties are early indicators of retinal …

    epfl Repository record for Phase-locked Fourier domain optical coherence tomography (opens in a new tab)

  8. Broadband single-chip transceivers for compact NMR probes

    … switches, IQ signal generation, and broadband quadrature detection. In this work we show multi-nuclear NMR spectroscopy in combination with excitation/detection probe-heads based on micro-solenoids, therefore validating the broadband functioning. A combination of the transceivers and Metrolab's …

    epfl Repository record for Broadband single-chip transceivers for compact NMR probes (opens in a new tab)

  9. Novel Embedded Metrology Instruments for the Light Controlled Factory

    … were analysed and the data gathered from the quadrature detection were interpreted. It was therefore possible to define the direction of the movement of the interferometric pattern and whether or not it had moved to the next fringe (or by a whole fringe).<br/><br/>Even though the diode laser …

    bath Repository record for Novel Embedded Metrology Instruments for the Light Controlled Factory (opens in a new tab)

  10. Detekce RF signálu u MRI

    Predkládaná bakalárská práce je zamerena na detekci MR signálu a na návrh laboratorního cvicení k danému tématu. Duraz je kladen na popis rozdílu mezi lineární a kvadraturní detekcí s ohledem na SNR. Pro práci v laboratorním cvicení byl vytvoren program v prostredí Matlab GUI, který je v textu …

    brno-tech Repository record for Detekce RF signálu u MRI (opens in a new tab)

  11. Kinetic discriminations for selective analysis in complex mixtures : applications in imaging

    … approche exploite la réponse au premier ordre en quadrature de phase d'une sonde photochrome soumise à une modulation lumineuse périodique. Un cadre théorique complet nous a permis d'identifier les conditions d'illumination qui maximisent cette réponse en ajustant les deux paramètres de contrôle, …

    star-france Repository record for Kinetic discriminations for selective analysis in complex mixtures : applications in imaging (opens in a new tab)

  12. Receive Radio-Frequency Coils for a Parallel B0 Linac-MR

    … also changes the orientation of the MRI’s signal detection plane. RF-coils must be sensitive to this plane through 360° of linac rotation. In this work the impact on surface dose due to copper and aluminum conductors of various thicknesses is investigated. The surface dose increase due to aluminum …

    alberta Repository record for Receive Radio-Frequency Coils for a Parallel B0 Linac-MR (opens in a new tab)