Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 25 for “"Quantitative computed tomography (QCT)"”
-
Optimizing fracture management: Correlating the physical and mechanical properties of bone to computed tomography to generate an estimate of bone quality
… patient outcomes in orthopaedic trauma. Quantitative computed tomography (QCT) is currently being investigated as a method of estimating structural bone mineral content (sBMC) and, thus, bone quality. However, the reported correlations between QCT and sBMC have been variable and the …
-
Property Estimation of Thin Cortical Bone from Clinical QCT: An Analysis by Synthesis Approach
… bone. Due to the limited spatial resolution of Quantitative Computed Tomography (QCT) the Nyquist-Shannon sampling theorem is violated, making direct reconstruction impossible. To overcome this, a probabilistic Analysis by Synthesis (AbS) framework is proposed that exploits the geometry of the …
-
Mapping Anisotropy of the Proximal Femur for Improved Image-Based Finite Element Analysis
… (FE) models of bone derived from clinical quantitative computed tomography (QCT) rely on realistic material properties to accurately predict patient-specific bone strength in vivo. QCT cannot resolve microarchitecture, therefore QCT-based FE models lack the directionality apparent within …
-
An investigation of bovine lumbar vertebral body stiffness with experimental measurement and finite element modelling
… of geometry and bone density (as obtained with Quantitative Computed Tomography, QCT), such FEM models may accurately predict strength and stiffness of human bone in the future.
-
DXA measurements using a micro computed tomograph system.
… is on Dual-Energy X-Ray Absorptiometry (DXA) and Quantitative Computed Tomography (QCT). The basic principle involving DXA is the ability to quantify the degree of attenuation of an energy beam after passage through bone and soft tissue. The X-ray tubes used with DXA narrow the energy beam to …
-
Assessment of Human Alveolar Bone Density by Using Volumetric CT Machine
… in designated implants sites using cone-beam computed tomography (CBCT) and compared the measurements to those of quantitative computed tomography (QCT) and subjective bone density evaluation. Sixty-two designated implant sites in 9 human cadavers jaws were used. Indicator rods, 2 mm in …
-
Quantifying the spatial distribution of intradiscal pressure and its assessment via non-invasive estimates of intervertebral disc degeneration
… degeneration was assessed non-invasively using quantitative computed tomography (QCT). A custom, electro-mechanical device was designed, manufactured and assembled to measure IDP distributions. The results indicated that the spatial distribution of IDP was most homogenous for the nucleus …
-
Comparisons of Patellar Bone Mineral Density Between Individuals with and without Patellofemoral Pain
… between individuals with and without PFP using quantitative computed tomography (QCT). The secondary aim was to examine the associations between patellar regional BMD and patellofemoral joint (PFJ) alignment. Methods: Ten individuals with retropatellar pain and 10 sex, age, weight, height, and …
-
In Vivo Assessment of Bone Microarchitecture and Estimated Bone Strength
… the assessment of bone structure in vivo using quantitative computed tomography (QCT) and high-resolution peripheral QCT (HR-pQCT). The overall objective of this thesis was to improve the assessment of bone structure and strength using three-dimensional imaging technologies. First, measurements …
-
Development and validation of an open-source QCT-based finite element analysis and phase field modeling for fracture prediction in goat tibia
… model of bone geometry was constructed from a 3D quantitative computed tomography (QCT) scan of the goat tibia. Density was calculated from Hounsfield values and spatially distributed within the FE mesh. To validate this FE model, we conducted a uniaxial compression test by applying the load along …
-
Assessment of Alveolar Bone Density Using Implant Insertion Resistance Torque
… were previously examined radiographically using quantitative computed tomography (QCT) and quantitative cone-beam computed tomography (QCBCT). Forty-two implant insertion sites randomly distributed throughout the range of bone densities as ranked by QCT and QCBCT Hounsfield Units (HU) were …
-
Time dependency of bone density estimation from computed tomography with intravenous contrast agent administration
… that in contrast-enhanced multi-detector computed tomography (MDCT)-based bone density measurements, the scan delay time after contrast agent administration is a statistically significant variable for the derivation of quantitative computed tomography (QCT)-equivalent bone mineral density …
-
Εκτίμηση του βαθμού οστεοπενίας και οστεοπόρωσης σε ομόζυγους β-θαλασσαιμικούς ασθενείς: σύγκριση και συσχέτιση των αποτελεσμάτων της διπλής φωτονιακής απορρόφησης (DXA) με αυτά της ποσοτικής υπολογιστικής τομογραφίας (QCT)
… using Dual-Energy X-ray Absorptiometry (DXA) and Quantitative Computed Tomography (QCT), and we focused on structural properties, assessed by High Resolution Computed Tomography (HRCT). Bone Mineral Density (BMD) values were expressed as Z scores and the results were correlated. The effect of age, …
-
PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY-DERIVED BONE OUTCOMES AND RELIABILITY IN RHEUMATOID ARTHRITIS PATIENTS AND CONTROLS
… erosions, but does not provide quantification. Quantitative computed tomography (QCT) allows for differentiation between bone layers and quantifies volumetric bone mineral density (vBMD). We used a peripheral QCT (pQCT) scanner in MTPJs 2-5 in RA patients to determine reliability of a pQCT …
-
Μελέτη οστικής πυκνομετρίας με νεότερες απεικονιστικές μεθόδους σε ασθενείς με χρόνια αποφρακτική πνευμονοπάθεια
… are Dual-Energy Absorptiometry (DXA) and Quantitative Computed Tomography (QCT) with the use of an external phantom.The aim of this thesis was to estimate bone density on COPD patients with these two methods and correlate the measurements with the patients’ body composition, COPD stage and …
-
IMAGE RECONSTRUCTION AND GEOMETRICAL MODELING OF BONE CROSS SECTIONS FROM LIMITED ANGLE DUAL ENERGY PROJECTION DATA
… by Dual-Energy X-ray Absorptiometry (DXA) or Quantitative Computed Tomography (QCT). Unfortunately, density criteria identify less than half of people at risk of osteoporotic fracture and do not adequately characterize the mechanical basis of fracture susceptibility. Identification of …
-
Computed tomographic characterization of the equine third metacarpal bone
… equine (SCB) density characteristics using computed tomographic osteoabsorptiometry (CTO) and quantitative computed tomography (QCT). Results will provide objective measures of SCB density in horses. Five metacarpophalangeal joints were CT scanned and four 1-cm3 regions of interest were …
-
3-D visualization and prediction of spine fractures under axial loading
… fracture risk. Using images obtained from micro-computed tomography (μCT) and quantitative computed tomography (QCT), the intra-vertebral heterogeneity in bone density was quantified in cadaveric specimens. Quantitative measures of this heterogeneity improved predictions of vertebral strength as …
-
3-D visualization and prediction of spine fractures under axial loading
… fracture risk. Using images obtained from micro-computed tomography (μCT) and quantitative computed tomography (QCT), the intra-vertebral heterogeneity in bone density was quantified in cadaveric specimens. Quantitative measures of this heterogeneity improved predictions of vertebral strength as …
-
ADDRESSING PARTIAL VOLUME ARTIFACTS WITH QUANTITATIVE COMPUTED TOMOGRAPHY-BASED FINITE ELEMENT MODELING OF THE HUMAN PROXIMAL TIBIA
Quantitative computed tomography (QCT) based finite element modeling (FE) has potential to clarify the role of subchondral bone stiffness in osteoarthritis. The limited spatial resolution of clinical CT systems, however, results in partial volume (PV) artifacts and low contrast between the cortical …
Page 1 of 2