Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 51 for “"Quantum Cascade Laser QCL"”.
-
Metamaterial resonant absorbers for terahertz sensing
… a terahertz (THz) imaging system with a 4.7 THz quantum cascade laser (QCL) illumination source. Finite element (FE) simulations were utilized to design metamaterials, and a Fourier transform infrared spectrometer (FTIR) was employed to characterize the absorption spectrum of each metamaterial …
-
Implementation of an optical readout system for high-sensitivity terahertz microelectromechanical sensor array
… device (CCD) camera for generating images. A quantum cascade laser (QCL) provided the THz illumination for generating images while post-image processing performed background subtraction in order to obtain the THz scene. The Fourier 4F optical readout system that was implemented was able to …
-
Development of compact DSP based mid-infrared quantum cascade laser spectrometers
… of digital signal processor (DSP) and quantum cascade laser (QCL) technology for compact, standalone, integrated, trace gas sensors capable of gas sensing at part-per-billion (ppb) concentration levels. Such sensitivity levels provide the ability to perform precise environmental and …
-
Characterization of terahertz bi-material sensors with integrated metamaterial absorbers
… detected incident power were measured using a quantum cascade laser (QCL), operating at 3.8 THz. The measured experimental data agree well with the theoretical calculated values of the performance parameters.
-
Imaging of 3.4 THz quantum cascade laser beam using uncooled microbolometer camera
… research. In this thesis, operation of a 3.4 THz quantum cascade laser (QCL) was successfully achieved using a closed cycle cryostat and nanosecond pulse generator with impedance matching circuitry. The laser beam was imaged in real time using an uncooled microbolometer infrared camera typically …
-
High Temperature Shock Tube and Laser Diagnostics Measurements of Fuel Combustion for Solid Fuel Ramjets
… time-resolved temperature were measured with a quantum cascade laser (QCL) in the mid-infrared (MIR) region and compared against chemical kinetics models: AramcoMech3.0, HyChem, and NUIG 1.3. Additional OH* measurements were taken with an emission detector to capture ignition delay time (IDT). …
-
METASURFACE-BASED MEMS THZ-TO-IR FOCAL PLANE ARRAY
… THz absorption, optimized to particular THz quantum cascade laser (QCL) illumination sources, was achieved using metal-dielectric metasurfaces. The metasurfaces are composed of ultra-thin films of silicon oxide and aluminum, deposited on silicon substrates, and were fabricated using standard …
-
Enhancing microbolometer performance at terahertz frequencies with metamaterial absorbers
… are accurate. Metamaterial structures tuned to a quantum cascade laser (QCL) illuminator were incorporated into a bi-material sensor, which was used for detection of THz radiation from the QCL source with good sensitivity. In the case of microbolometers, a bolometric layer needs to be embedded in …
-
Terahertz imaging via a microbolometer camera under illumination of a quantum cascade laser
… detectors. This thesis aimed on characterizing a quantum cascade laser (QCL) beam and achieving high quality real-time THz imaging using a 160x120 pixel FLIR A20M microbolometer camera designed to operate in long wave infrared range. The FTIR spectroscopy of the QCL beam revealed that lasing could …
-
Real time imaging analysis using a terahertz quantum cascade laser and a microbolometer focal plane array
… imaging of concealed objects using a 1mW quantum cascade laser (QCL) and an uncooled vanadium oxide/silicon nitride based microbolometer. This thesis introduces an amorphous silicon based microbolometer with improved NETD in the 8-12 micrometer infrared spectral range. The QCL is usually …
-
Terahertz quantum cascade structures using step wells and longitudinal optical-phonon scattering
… terahertz (THz) longitudinal optical (LO)-phonon quantum cascade (QC) structures were modeled, in order to investigate high gain quantum cascade laser (QCL) structures. A new structure, a step well QC structure, was proposed. Under such an arrangement, there are three main energy levels within the …
-
Real-time terahertz imaging using a quantum cascade laser and uncooled microbolometer focal plane array
… microbolometer camera and a milliwatt-scale quantum cascade laser (QCL). By replacing the camera's original focusing optics with a Tsurupica-based lens and minimizing diffraction effects incurred by the QCL output beam, an imaging scheme was developed in which the camera's focal plane array …
-
Zinc & Nitride based QCL: A High Power Room Temperature Terahertz Source
In this thesis, a ZnO/Zn1-xMgxO based quantum cascade laser (QCL) is proposed as a candidate for generation of THz radiation at room temperature. The effect of spontaneous and piezoelectric polarizations are used to investigate THz generation. In addition, we compare absorption coefficient, optical …
-
Photothermal imaging of PMMA film and photothermal spectroscopy of pHEMA hydrogel
… utilizes a near-infrared erbium doped fiber laser (EDFL) to detect the photothermal induced changes in the refractive index. These changes are excited by a mid-infrared quantum cascade laser (QCL) pump beam. The probe beam is detected by a commercially available near-infrared photodetector. …
-
InAs/AlSb Based Mid-Infrared QCL Growth and XRD Simulation
In the past two decades, mid-infrared (MIR) quantum cascade laser (QCL) research has been rapidly developed and has resulted in an enabling platform for the remote sensing and metrology. QCL is designed by spatial confinement in quantum well structures on a nanometer scale, enabling the transitions …
-
Intracavity Laser Absorption Spectroscopy Using Quantum Cascade Laser And Fabry-perot Interferometer
Intracavity Laser Absorption Spectroscopy (ICLAS) at IR wavelengths offers an opportunity for spectral sensing of low vapor pressure compounds. We report here an ICLAS system design based on a quantum cascade laser (QCL) at THz (69.9 m) and IR wavelengths (9.38 and 8.1 m) with an open external …
-
Highly tunable room temperature quantum cascade lasers
… was conducted into the feasibility of novel Quantum Cascade Laser (QCL) technology to replace Optical Parametric Oscillator based light sources in real-time video-rate gas imaging systems. Such a laser must produce pulses of >5ns in duration at a repetition rate of at least 5kHz with peak …
-
Quantum cascade laser based spectroscopic sensor systems for trace gas detection
Quantum cascade laser (QCL) based spectroscopic techniques are useful for the quantitative detection and monitoring of molecular trace gas species in the mid-infrared spectral region. Sensitive and selective trace gas detection can be realized by targeting distinct and strong absorption lines in …
-
Characterization, Imaging, and Modeling of Thermal Dynamics and Failure Mechanisms of Quantum Cascade Lasers
As advancements in Quantum Cascade Laser (QCL) technology continue to push the upper limits of continuous-wave performance, effective thermal management remains at the forefront of design considerations. The compact and highly tunable active region that has made QCL technology so attractive also …
-
Terahertz Quantum Cascade Lasers: towards high performance operation
… systems, free space communication, etc. THz quantum cascade laser (QCL), as the relatively high power and coherent THz radiation source, was demonstrated in 2002. After near a decade of intense research, THz QCLs operate only up to 186K in pulse mode with maximum power of 250 mW at 10 K. This …
Page 1 of 3