Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"Quartz crystal microbalances"”.

  1. A study of recognition coating response for quartz crystal microbalances

    … sorption interactions for chemically coated Quartz Crystal Microbalances (QCMs). When exposed to the individual vapors of a homologous series of carboxylic acid vapors, a QCM coated with varying thicknesses of poly(ethylenimine) (PEI) coating, produces a linear response that is sensitive and …

    unlv Repository record for A study of recognition coating response for quartz crystal microbalances (opens in a new tab) Download PDF for A study of recognition coating response for quartz crystal microbalances (opens in a new tab)

  2. Instrumental techniques for improving the measurements based on Quartz Crystal Microbalances (Técnicas instrumentales para mejorar las mediciones con microbalanzas de cuarzo)

    L'Electrogravimetria AC empra una microbalança de quars electroquímica (EQCM) en règim dinàmic. En l'EQCM un dels elèctrodes d'or depositats sobre el cristall és recobert amb una fina pelolícula d'un polímer electroactiv i és emprat com a elèctrode de treball (WE) dins d'una celola electroquímica. …

    upv Repository record for Instrumental techniques for improving the measurements based on Quartz Crystal Microbalances (Técnicas instrumentales para mejorar las mediciones con microbalanzas de cuarzo) (opens in a new tab)

  3. Condensation and sublimation of carbon dioxide and water molecules at cryogenic temperatures

    … H₂O have been made using a molecular beam and quartz crystal microbalances. The dependence of the condensation coefficient on variables such as population density on the substrate, temperature of the substrate, molecular beam intensity and temperature of the molecular beam, was investigated. …

    must-thes Repository record for Condensation and sublimation of carbon dioxide and water molecules at cryogenic temperatures (opens in a new tab)

  4. Development of a Magnetically Enhanced Quartz Crystal Microbalance

    … sensing devices, more specifically: quartz crystal microbalances (QCM). In an attempt to push the detection limit of these devices, a race to find novel methods for enhancing the resonator output has transpired. This study explores the feasibility and implementation of a technique in …

    unr Repository record for Development of a Magnetically Enhanced Quartz Crystal Microbalance (opens in a new tab)

  5. Sorption of Benzene, Toluene and Ethylbenzene by Plasticized Poly (Ethyl Methacrylate) Using Quartz Crystal Microbalance at 298.15K

    Quartz crystal microbalances (QCM) are chemical sensors used for liquid and vapor sensing. In this thesis work, plasticized poly (ethyl methacrylate) (PEMA) coated QCM was used to study sorption behavior of benzene, ethylbenzene and toluene in respective polymer at 298.15K. Poly (ethyl …

    usf Repository record for Sorption of Benzene, Toluene and Ethylbenzene by Plasticized Poly (Ethyl Methacrylate) Using Quartz Crystal Microbalance at 298.15K (opens in a new tab)

  6. Sorption of Benzene, Dichloroethane, Chloroform and Dichloromethane by Polyethylene Glycol, Polycaprolactone and Their Copolymers at 298.15 K Using a Quartz Crystal Microbalance

    Quartz crystal microbalances (QCM) are acoustic wave sensor systems which are used majorly for vapor and liquid sensing. QCM come under the category of thickness shear mode (TSM) sensors. There are several methods to study organic vapor sensing; the QCM method is the one that offers the highest …

    usf Repository record for Sorption of Benzene, Dichloroethane, Chloroform and Dichloromethane by Polyethylene Glycol, Polycaprolactone and Their Copolymers at 298.15 K Using a Quartz Crystal Microbalance (opens in a new tab)

  7. Arabinoglucuronoxylan and Arabinoxylan Adsorption onto Regenerated Cellulose Films

    … between cellulose and hemicelluloses, and quartz crystal microbalances with dissipation monitoring (QCM-D), surface plasmon resonance (SPR) and atomic force microscopy (AFM) are widely used to investigate polymer adsorption/desorption at liquid/solid interfaces. In this study, smooth …

    vt Repository record for Arabinoglucuronoxylan and Arabinoxylan Adsorption onto Regenerated Cellulose Films (opens in a new tab)

  8. Sorption Of Organic Vapors By Copolymers Of Poly (Styrene-Butadiene) Using A Piezoelectric Microbalance

    Thickness shear mode (TSM) sensors, also known as quartz crystal microbalances (QCM) are a class of acoustic wave sensors that have been used for gas phase sensing. In this thesis this device is used to measure vapor-liquid equilibrium data for copolymers of poly(styrene-butadiene) at 294K. …

    usf Repository record for Sorption Of Organic Vapors By Copolymers Of Poly (Styrene-Butadiene) Using A Piezoelectric Microbalance (opens in a new tab)

  9. Near Field Electrospinning of Nanofibers for Multi-Modal Hydrogen Sensing

    … resonance-based sensing approaches using both quartz tuning forks (QTF) and quartz crystal microbalances (QCM). Near-field electrospinning is used to deposit uniform, semi-conductive nanofibers connecting the two prongs of a QTF. Electrospinning parameters are also optimized on QCM to maximize …

    calgary Repository record for Near Field Electrospinning of Nanofibers for Multi-Modal Hydrogen Sensing (opens in a new tab)

  10. Detection of Quercetin using Polymer Coated Quartz Crystal Microbalance and the Modification of á-Zirconium Phosphate to Develop a Sorbent for Organic Pollutant Removal

    … on the use of polymers to develop coatings for quartz crystal microbalances as well as layered zirconium phosphate for developing sorbents for organic pollutant removal. In Chapter 2, a brief summary of the analytical techniques used in this study, as well as preparation methods for the …

    marquette Repository record for Detection of Quercetin using Polymer Coated Quartz Crystal Microbalance and the Modification of á-Zirconium Phosphate to Develop a Sorbent for Organic Pollutant Removal (opens in a new tab)

  11. Engineering Applications of Surface Plasmon Resonance: Protein–Protein and Protein–Molecule Interactions

    … Surface plasmon resonance (SPR) devices and quartz crystal microbalances (QCM) are two real-time, label free methods that can be used to detect the interactions between molecules on surfaces. These devices often employ self-assembled monolayers (SAMs) to produce specific surfaces for studying …

    waterloo Repository record for Engineering Applications of Surface Plasmon Resonance: Protein–Protein and Protein–Molecule Interactions (opens in a new tab)

  12. Detection of Lysophosphatidic Acid in Serum; Towards a Cost Effective Test for Ovarian Cancer

    … transverse shear mode biosensors, also known as quartz crystal microbalances, showed that the background fouling signal was too large for a test to be developed on this class of devices. Instead a test based on colorometric sensing of dye modified actin was conceived and evaluated. This test …

    toronto-retro Repository record for Detection of Lysophosphatidic Acid in Serum; Towards a Cost Effective Test for Ovarian Cancer (opens in a new tab)

  13. Assessing the Adsorption of Various Proteins with Conformational Screening Utilizing k-Means Clustering and CHARMM Potential Energy Calculations

    Utilizing Quartz Crystal Microbalances (QCMB) to study the interaction of biochemical systems at interfaces is a diverse field with many potential applications. However, with an unfunctionalized surface, this technique suffers from a lack of known binding specificity which can denature the protein …

    clemson Repository record for Assessing the Adsorption of Various Proteins with Conformational Screening Utilizing k-Means Clustering and CHARMM Potential Energy Calculations (opens in a new tab)

  14. Studying the Interactions of Biomacromolecular Assemblies with Surfaces Using the Microcantilever Sensor and Quartz Crystal Microbalance

    … characterized using microcantilever sensors and quartz crystal microbalance with dissipation (QCM-D). The first part of this thesis reports the use of microcantilever beams, an ultrasensitive sensor for measuring the surface free energy changes on a substrate induced by molecular adsorptions, to …

    rice Repository record for Studying the Interactions of Biomacromolecular Assemblies with Surfaces Using the Microcantilever Sensor and Quartz Crystal Microbalance (opens in a new tab)

  15. Observing the Sedimentation of TiO2 Nanoparticles in Aqueous Solution Using a Quartz Crystal Microbalance with Dissipation Monitoring

    … of a novel and less expensive approach to the quartz crystal microbalance with dissipation monitoring (QCM-D) is explored. Using a vector network analyzer (VNA) to measure harmonic ranges from the primary to the 89th harmonic of a 5 MHz crystal. The fast read and processing ability of the VNA …

    umkc Repository record for Observing the Sedimentation of TiO2 Nanoparticles in Aqueous Solution Using a Quartz Crystal Microbalance with Dissipation Monitoring (opens in a new tab)

  16. Interfacial Study of Copper Electrodeposition with the Electrochemical Quartz Crystal Microbalance (EQCM)

    The electrochemical quartz crystal microbalance (EQCM) has been proven an effective mean of monitoring up to nano-scale mass changes related to electrode potential variations at its surface. The principles of operation are based on the converse piezoelectric response of quartz crystals to mass …

    unt Repository record for Interfacial Study of Copper Electrodeposition with the Electrochemical Quartz Crystal Microbalance (EQCM) (opens in a new tab)

  17. Quartz crystal microbalance adsorption apparatus for high pressure gas adsorption measurements in nanomaterials

    … porous materials and nanotubes. A high pressure Quartz Crystal Microbalance (QCM) based adsorption apparatus for single-component gas was developed. A QCM is an acoustic-wave resonator in which the acoustic wave propagates through the crystal. Therefore, it is highly responsive to addition or …

    gatech Repository record for Quartz crystal microbalance adsorption apparatus for high pressure gas adsorption measurements in nanomaterials (opens in a new tab)

  18. Understanding adhesion to monitor and control environmental processes : from virus detection to membrane fouling mitigation

    … fomites and humans. In this dissertation, Quartz Crystal Microbalance with Dissipation monitoring (QCM-D) is employed to quantify virus attachment to fomites. XDLVO modeling is applied to predict the virus-fomites interactions. Virion size, surface charge and surface energy components as …

    msu Repository record for Understanding adhesion to monitor and control environmental processes : from virus detection to membrane fouling mitigation (opens in a new tab)

  19. Synthesis and Combinatorial Optimization of Novel Star-Shaped Resist Materials for Lithographic Applications

    … of the resist film was established utilizing quartz crystal microbalances. Based on this measured dissolubility behavior the time frame was set for development time gradients performed by a stepwise or continuously immersion of the resist films. Lastly two to three variable gradients were …

    bayreuth Repository record for Synthesis and Combinatorial Optimization of Novel Star-Shaped Resist Materials for Lithographic Applications (opens in a new tab)

  20. Magnetic quartz crystal microbalance

    In this thesis, a new technique for using quartz crystal microbalance (QCM) in magnetic field was explored. This technique would take advantage of the sensitive nature of QCM to vibration changes. The idea is to perturb the QCM vibrations with magnetic materials on it by applying magnetic field. A …

    gatech Repository record for Magnetic quartz crystal microbalance (opens in a new tab)

Page 1 of 2