Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 15 of 15 for “"Quartz microbalance"”

  1. Wine Discrimination and Analysis Using Quartz Microbalance Based Electronic Nose Technology

    … wine discrimination techniques. In this study, a quartz microbalance-based electronic nose system was utilized to analyze the overall volatile components of wine. The electronic nose was optimized for Cabernet Sauvignon and Mouvèdre wine to gain maximum sensor response from the sensors. Response …

    vt Repository record for Wine Discrimination and Analysis Using Quartz Microbalance Based Electronic Nose Technology (opens in a new tab)

  2. Development of Novel Macromolecular Organic Semiconductors for their Applications in Organic Electronics

    … materials to create sensing films onto quartz microbalance (QMB) sensors for mass-based detection and interdigitated electrode (IDE) sensors for electronic-based detection of various gases and volatile organic compounds (VOCs). Overall, this thesis demonstrates the design and …

    ottawa-retro Repository record for Development of Novel Macromolecular Organic Semiconductors for their Applications in Organic Electronics (opens in a new tab)

  3. Structure and reactivity of selected inclusion compounds

    … 1, 3-dioxolane was studied, using a quartz microbalance designed especially forth is purpose.

    cape-town Repository record for Structure and reactivity of selected inclusion compounds (opens in a new tab)

  4. Characterization of structural degradation in a polymer electrolyte membrane fuel cell cathode catalyst layer

    … water content. A method using an electrochemical quartz microbalance (EQCM) was investigated to further evaluate ionomer degradation. Mimicking the ionomer films in the CCL on the EQCM would enable a quantitative method to further evaluate the degradation reactions and overall mechanism. While …

    ubc Repository record for Characterization of structural degradation in a polymer electrolyte membrane fuel cell cathode catalyst layer (opens in a new tab)

  5. Metal organic frameworks as sorbents for volatile organic compounds

    … onto Au-coated Si wafers and Au-coated quartz crystal microbalance surfaces using a vapor-assisted conversion method. The films were then characterized by scanning electron microscopy, powder x-ray diffraction, x-ray photoelectron spectroscopy, reflection absorbance infrared …

    alabama Repository record for Metal organic frameworks as sorbents for volatile organic compounds (opens in a new tab)

  6. Neutron tunneling in nanostructured systems: isotopical effect

    … thickness layers were monitored by a calibrated quartz microbalance. Unpolarized neutron reflectometry measurements were carried out at the ORPHEE reactor using the time-of-flight EROS reflectometer. The incidence neutron wavelength varied between 3 – 25 Å. The grazing angle and angular …

    unisa-za Repository record for Neutron tunneling in nanostructured systems: isotopical effect (opens in a new tab)

  7. Sustainable synthesis of FeMn films and fabrication of Fe/Mn-based micromotors

    … performed in combination with electrochemical quartz microbalance measurements in the MnSO4 containing electrolytes and a suitable deposition potential range was identified. The electrolyte composition played an important. The addition of H3BO3 provided mechanical stability to the Mn films and …

    qucosa-diss Repository record for Sustainable synthesis of FeMn films and fabrication of Fe/Mn-based micromotors (opens in a new tab)

  8. Compréhension et prédiction des réponses de capteurs chimiques de gaz à surface de matériaux sensibles : application aux polysiloxanes fonctionnalisés.

    … sensibles. Les travaux ont porté sur des microbalances à quartz revêtues de polysiloxanes fonctionnalisés. Des mesures à l'équilibre, en exposant ces capteurs à différentes vapeurs organiques, ont mis en évidence la sélectivité des matériaux employés. Pour rationaliser ces résultats, les …

    star-france Repository record for Compréhension et prédiction des réponses de capteurs chimiques de gaz à surface de matériaux sensibles : application aux polysiloxanes fonctionnalisés. (opens in a new tab)

  9. Investigation into the effects of ionising radiation on plasma polymer monoterpene alcohols for applications in organic electronics

    … thin films were examined using crystal quartz microbalance analysis, spectroscopic ellipsometry, atomic force microscopy, Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, scanning electron spectroscopy, energy dispersive X-ray spectroscopy, Raman spectroscopy, …

    jamescook Repository record for Investigation into the effects of ionising radiation on plasma polymer monoterpene alcohols for applications in organic electronics (opens in a new tab)

  10. Polyamic acid composites for multiiple sensing applications in complex sample matrices

    Polyamic acid-polypyrrole (PAA/PPy) composite films were prepared and characterised for the use as conducting platforms in the design of biosensor systems. The thin films were synthesised by electrochemical method from a solution containing controlled molar ratio of chemically synthesised polyamic …

    western-cape Repository record for Polyamic acid composites for multiiple sensing applications in complex sample matrices (opens in a new tab)

  11. Étude de nanocomposites polypyrrole/nanoparticule de carbone par impédance électrochimique et ac-électrogravimétrie : application aux capteurs électrochimiques

    … simultané de mesures gravimétriques de la microbalance à quartz et d’impédance électrochimique. L’originalité de ce travail consiste donc en l’élaboration et la caractérisation d’électrode à base de nouveaux nanocomposites et de leurs applications comme capteurs électrochimiques peu …

    star-france Repository record for Étude de nanocomposites polypyrrole/nanoparticule de carbone par impédance électrochimique et ac-électrogravimétrie : application aux capteurs électrochimiques (opens in a new tab)

  12. Improved characterization systems for quartz crystal microbalance sensors: parallel capacitance compensation for variable damping conditions and integrated platform for high frequency sensors in high resolution applications

    … major parameters for the characterization of quartz crystal microbalance (QCM) during the last two decades. The measurement of the adequate parameters of the sensor for a specific application is very important, since an error in this measure can lead to an error in the interpretation of the …

    upv Repository record for Improved characterization systems for quartz crystal microbalance sensors: parallel capacitance compensation for variable damping conditions and integrated platform for high frequency sensors in high resolution applications (opens in a new tab)

  13. Εκτίμηση της αλλοίωσης του κρέατος με σύγχρονες μεθόδους

    … and test datasets.The performance of a portable quartz microbalance based electronic nose has beenevaluated in monitoring aerobically and under MAP packaged minced pork spoilage at differentstorage temperatures (0, 5, 10, 15, and 20°C). Electronic nose data were collected from theheadspace of …

    greece Repository record for Εκτίμηση της αλλοίωσης του κρέατος με σύγχρονες μεθόδους (opens in a new tab)

  14. Comportement mécanique de films minces de chalcogénures sous irradiation de photons

    … (inférieure à lananoseconde) et les capteurs au quartz piezoélectrique qui permettent de mesurerla masse volumique et les modules mécaniques du matériau déposé à leurs surface.Des essais préliminaires de résonance en transmission ont été également réalisés etsont prometteurs. Une machine de DMA …

    star-france Repository record for Comportement mécanique de films minces de chalcogénures sous irradiation de photons (opens in a new tab)

  15. Etude des propriétés de surface de nanoparticules à l’interface avec les fluides biologiques et les membranes cellulaires

    … des modèles membranaires ont été suivies par microbalance à quartz (QCM-D) et résonance plasmonique de surface (RPS). Les NPs fonctionnalisées sont plus rapidement internalisées que les NPs natives, en particulier les NPs recouvertes de bicouches lipidiques, mais sont moins toxiques pour les …

    star-france Repository record for Etude des propriétés de surface de nanoparticules à l’interface avec les fluides biologiques et les membranes cellulaires (opens in a new tab)