Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 10 of 10 for “"Quasi-3 Dimensional"”

  1. Quasi 3-Dimensional Electrical Resistivity Mapping of Air-filled Karst Conduits and Policy Implications

    … the capability and practical applications of quasi 3-Dimensional (3D) electrical resistivity surveying (ER) for mapping air-filled karst conduits. Vadose zone caves within the Brooksville Ridge of West Central Florida are relatively similar in architecture, with N-S elongation, and do not …

    usf Repository record for Quasi 3-Dimensional Electrical Resistivity Mapping of Air-filled Karst Conduits and Policy Implications (opens in a new tab)

  2. Thermoelectric magnetohydrodynamics in dendritic solidification

    … become significant. The problem is purely 3-dimensional and it is shown that classical 2-dimensional boundary conditions lead to stagnant conditions. A 2-dimensional quasi 3-dimensional approximation is proposed and, with the magnetic field orientated in the (001) direction, the effect of …

    greenwich Repository record for Thermoelectric magnetohydrodynamics in dendritic solidification (opens in a new tab)

  3. Nonlinear analysis of bonded joints with thermal effects

    … or aluminum adherends are analyzed using a quasi 3-dimensional finite element analysis. In adhesively bonded joints, the adhesives considered are Metlbond 1113 and AF-126-2. Elastic results are presented for single and double lap joints, with and without adhesives. It is shown that …

    vt Repository record for Nonlinear analysis of bonded joints with thermal effects (opens in a new tab)

  4. A Finite-Element Method for the Solution of Turbine-Generation End-Zone Fields

    … in the peripheral direction, so that the 3-dimensional problem can be treated by a "quasi-3-dimensional" method, involving radial and axial distances only. The solution is obtained as a scalar potential distribution, from which the component flux densities can be derived. Following proving …

    aston Repository record for A Finite-Element Method for the Solution of Turbine-Generation End-Zone Fields (opens in a new tab)

  5. Simulating dioxane transport in a heterogeneous glacial aquifer system (Washtenaw County, Michigan) using publicly available models and data

    … simulates transient groundwater flow in a quasi-3-dimensional sense, subject to a variety of boundary conditions that can simulate recharge, pumping, and surface-/groundwater interactions. MT3D simulates solute advection with groundwater flow (using the flow solution from MODFLOW), …

    mtu Repository record for Simulating dioxane transport in a heterogeneous glacial aquifer system (Washtenaw County, Michigan) using publicly available models and data (opens in a new tab)

  6. The Manufacturing and Ballistic Testing of Tri-axial Quasi Three Dimensional Woven Composites Layered in Polyurea

    … resistance and self-sealing nature of a quasi 3D tri-axial woven composite layered with polyurea against high power rifle bullet impact. This is done by evaluating the effectiveness of quasi-3D tri-axial woven composites in resisting .50 caliber rifle rounds and utilizing a high speed …

    mississippi Repository record for The Manufacturing and Ballistic Testing of Tri-axial Quasi Three Dimensional Woven Composites Layered in Polyurea (opens in a new tab)

  7. The Development and Application of a Simplified Thermal Performance Equation for a Sheet-and-Tube Photovoltaic Thermal Combi-Panel

    … wide range of conditions. To accomplish this, a quasi- 3-dimensional steady-state model of a sheet-and-tube PV/T collector was developed and used to generate a broad data set from which a simplified PV/T performance equation was developed. Using this numerically generated data set, and …

    queens Repository record for The Development and Application of a Simplified Thermal Performance Equation for a Sheet-and-Tube Photovoltaic Thermal Combi-Panel (opens in a new tab)

  8. Quantitative assessment of image quality in digital breast tomosynthesis

    … slices of the breast [3]. A limitation of the 2-Dimensional (2D) Mammography X-ray imaging acquisition technique is the superimposition of normal and pathological structures. Tissues and structures of the breast are projected onto the detector, which is in a plane perpendicular to the X-ray …

    patras-thes Repository record for Quantitative assessment of image quality in digital breast tomosynthesis (opens in a new tab)

  9. Quantitative assessment of image quality in digital breast tomosynthesis

    … slices of the breast [3].A limitation of the 2-Dimensional (2D) Mammography X-ray imaging acquisition technique is the superimposition of normal and pathological structures. Tissues and structures of the breast are projected onto the detector, which is in a plane perpendicular to the X-ray …

    greece Repository record for Quantitative assessment of image quality in digital breast tomosynthesis (opens in a new tab)