Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 7 of 7 for “"Quasi-static cyclic testing"”
-
Wind Performance of Sheathing-to-Rafter Connection of HUD Code Wind Zone II and III Manufactured Homes
… behavior and wind performance. A two-step quasi-static cyclic testing protocol, that started with monotonic testing which informs the second step of cyclic testing, was used to quantify fastener uplift capacity. This investigation presents comparisons across different fastener types, rafter …
-
Performance of unstiffened steel plate shear walls under cyclic quasi-static loading
… in areas of high seismic risk. An experimental testing programme was conducted at the University of British Columbia on two single and one multistorey steel plate shear wall assemblies. Each specimen consisted of a single bay, 30 % scale model of an inner residential building core with panel …
-
Seismic performance of an I-girder to inverted-T bent cap bridge connection
… unit was constructed and tested in two phases of quasi-static cyclic testing. The first phase was a horizontal load test phase, which simulated the effects of gravity and seismic loads on the entire test unit. The second phase was a vertical load test phase, which specifically focused on the …
-
Seismic Retrofit of Reinforced Concrete Shear Walls Using Selective Weakening and Self-Centering
… retrofit solution to alter failure modes. Quasi-static cyclic testing of three one-third length scale specimens, one pre-retrofit and two post-retrofit walls, demonstrated that the proposed retrofit method changed a shear/flexure response to a more ductile rocking response. The damage …
-
Force-displacement response of unreinforced masonry walls for seismic design
… During all tests, the walls were subjected to quasi-static cycles of increasing drift demands, while controlling the boundary conditions (axial load and moment restraint at the top of the walls) such to simulate the typical loading of a ground floor wall in an URM building. From the experiments …
-
Seismic behaviour of steel plate shear walls by shake table testing
… broaden the scope of the code, an experimental testing program accompanied by numerical investigation was conducted at the University of British Columbia. This effort was in collaboration with researchers at the University of Alberta and a team of consulting engineers. During the first phase of …
-
Seismic Performance and Building Height Limits of Ductile Reinforced Concrete Masonry Shear Walls with Boundary Elements
… load, along with in-plane fully reversed cyclic loading synchronized with top moment. The tested walls represented the plastic hinge region of prototype 6- and 12-storey RCM structural walls. The studied parameters are the boundary element’s length, the boundary element’s vertical …