Capacitive Chest Strap for Heart Rate Monitoring
… During stationary condition testing, R-peaks were detectable, achieving 100% accuracy in R-peak detection, including the fully capacitive case and with all fabrics tested as interface body-electrode. For testing during body movement, fi ve participants were recruited, and ethics approval …
-
Modelagem por partes da cinética da resposta cronotrópica cardíaca durante a caminhada em esteira ergométrica
… the variations in the intervals between a R-peak and another (IRR) of the electrocardiogram (ECG) in response to walking steps through an exponential first order model. Twenty-five men, young and healthy, performed the test protocol comprised of: 1 min of rest, followed by 2 min of warming up …
-
Fast Stress Detection via ECG
… about each cardiac-cycle, where the R-peak is placed in the middle of the PQRST complex and represents the maximum value of the PQRST. Since the PQRST depicts the entire cardio-cycle, the R–peak determines half of the cardio-cycle. The distance between two adjacent R-peaks is defined as …
-
The mechanics of cell-seeded collagen hydrogels
… Coefficient (M), Correlation Coefficient (r²), peak stress and equilibrium stress. Results and conclusions: No statistically significant trends were determined for the mechanical properties between cell seeding densities, however differences in hydraulic permeability and peak stress were …
-
An Instantaneous Frequency Based Approach to Estimate Heart Rate and Calculate Heart Rate Variability Metrics
… calculated using the interval between R peaks in an EKG signal. Consequently, heart rate measurements rely on the presence of distinctive R peaks and the accurate detection of them. The study is motivated by the drawbacks associated with using R peaks to calculate instantaneous heart …
-
A Novel Smart Wearable System with Edge Computing AI for Cardiac Disease Detection and Continuous Monitoring
… QRS detection block offers 99.6% accuracy for R peak detection and a low overall R peak position error (RPE) of 6.3 ms. The real-time feature extraction block offers a good correlation factor of 95.1% with reference data. This resource-constrained DNN model is 98.1% accurate in detecting …
-
Automatic detection of qt and related intervals
… on the derived signal of ECG starting from the R peak. The T_{max} was detected by two different procedures. The first procedure was a combination of two different methods: the Least Squares Method (LSI) and the Threshold Method (TH) and the second procedure was based on the Differential Threshold …
-
Denoise high dimensional dataset with complicated noise and its clinical applications
… Arrhythmia Database. </p><p>For the fetal R peak detection, the proposed algorithm outperforms all algorithms under comparison. For the morphological analysis, the algorithm provides an encouraging result in recovery of the fetal ECG waveform, including PR, QT and ST intervals, even when the …
-
Growth and morphological acclimation of seedlings to blue, green, and red light from light-emitting diodes
… to quantify how different ratios of blue (B, peak=446 nm), green (G, peak=516 nm), orange (O, peak=596 nm), red (R, peak=634 nm), and hyper red (HR, peak=664 nm) from light-emitting diodes (LEDs) regulated plant growth while maintaining similar cultural and environmental conditions. Seedlings …
-
Deep learning applied to non-invasive ECG pregnancy monitoring : fetal ECG recovery and QRS complex detection
… functions centered on annotations of the R-peak position in the fQRS complex available in public datasets. Using these regions, an optimization function was proposed for training the model, considering the reconstruction of the fECG in the region of interest, the global fECG, and the RoI. …
-
Convolutional Neural Network in Pattern Recognition
… transformer, greatly benefits from correct R-peak detection results and conceptual fuzzification. Recently proposed self-attention mechanism has been proven to be the top performer in the fields of computer vision and natural language processing. In spite of the pleasant accuracy and precision …
-
Novel ECG analysis with application to atrial fibrillation detection
… The signal is divided according to R to R peak interval (RRI) before superimposing with the rectangular pulses. The research also investigates the use of the P to T peak interval (PTI) as the signal limiter as an alternative to RRI approach and has shown encouraging performance. The …
-
Zpracování elektrokardiogramu
Táto bakalářská práce se zabývá zpracováním elektrokardiogramu (EKG) v programovém prostředí LabView. Hlavní část je program na zpracování EKG, včetně potlačení různých šumů a detekování R-piku, vytvořen v prostředí LabView. Použití komponenty a postup realizace dílčích časti programu sou popsané v …
-
Signal processing methods for characterisation of ventricular repolarisation using the surface electrocardiogram
… (UWT). The UWT coefficients are used for R-peak detection, signal encoding for the HMM and a wavelet de-noising procedure. Using the Viterbi algorithm, the trained HMM is then applied to a subset of the ECG signal to infer the fiducial points for each heart beat. Furthermore, a method for …
-
Potentials Of Physiological Signals To Implement A Wearable Drowsiness Detection And Warning System For Pilots
… using ECG, PP intervals, crest time, diastolic peak time, systolic peak to diastolic peak, and diastolic time using PPG increased significantly during drowsy periods. Pulse arrival time (PAT) calculated using ECG R-peak and PPG peak increased significantly (p<0.05) during drowsy periods compared …
-
Analysis of beat-to-beat QT interval variability in 12-lead ECG signals.
… of beat-to-beat QTV. It substitutes the R-peak detection algorithm and implements an efficient baseline removal algorithm in the existing template matching approach. (vi) Effects of T-wave amplitude and ECG lead on beat-to-beat QTV in patients with Myocardial Infarction (MI) compared to …
-
Towards an Accurate ECG Biometric Authentication System with Low Acquisition Time
… processing approaches for filtration and R-peak detection, a feature extractor and an authentication process. To evaluate this system, we developed a method to calculate the Equal Error Rate—EER—with non-normal distributed data. In the authentication process, we propose an approach based on …
-
The Effect of Spironolactone on Cerebral Blood Flow and Cognition
… index increase). Transit times from R-peak of QRS complex to foot of aortic velocity pulse, carotid artery, or finger artery significantly increased with progressively increasing LBNP as a consequence of longer pre-ejection period (P<0.001). In conclusion for the main thesis objective, …
-
Neonatal brain injury detection using advanced deep learning architectures
… algorithm was developed to improve R-peak detection robustness in noisy EEG recordings. This enhancement significantly increased the availability and quality of extracted heart rate signals. A hybrid Convolution-Transformer architecture, termed HRVConformer, was introduced for …
Page 1 of 2