Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 18 of 18 for “"R-113"”

  1. Pool boiling from GEWA surfaces in water and R-113

    … The working fluids were distilled water and R-113. The overall enhancement (defined as the ratio of wall superheat for the smooth tube to that of the enhanced tube, at constant heat flux) was higher in R-113 than in water. With R-113 the enhancement was a well-behaved function of S(,T). With …

    iastate Repository record for Pool boiling from GEWA surfaces in water and R-113 (opens in a new tab)

  2. Enhanced condensation of R-113 on a small bundle of horizontal tubes

    Condensation of r-113 was studied using an evaporator condenser test platform. the condenser section contained four horizontal tubes (nominal outer diameter 15.9 mm)forming a vertical in line column with a pitch-to-diameter ratio of 2.25 and a condensing length of 1.2 m. the condenser tubes could …

    nps Repository record for Enhanced condensation of R-113 on a small bundle of horizontal tubes (opens in a new tab)

  3. Nucleate boiling characteristics of R-113 in a small enhanced tube bundle.

    Heat transfer tests were carried out using a small enhanced tube bundle in a pool of R-l 13. By accurately instrumenting five tubes within the bundle, both the convective and nucleate boiling regions were studied in detail, with emphasis on the 'bundle' effect (i.e. the effect of lower tubes in …

    nps Repository record for Nucleate boiling characteristics of R-113 in a small enhanced tube bundle. (opens in a new tab)

  4. Nucleate pool boiling performance of smooth and finned tube bundles in R-113 and R-114/oil mixtures

    … The smooth tube bundle was tested in pure R-113 with varying surface "histories" as well as with pure R-114 and R-ll4/oil mixtures. The finned tube bundle was tested in pure R-114 and R-114/oil mixtures. Oil concentrations used were 1, 2, 3, 6, and 10% by mass.

    nps Repository record for Nucleate pool boiling performance of smooth and finned tube bundles in R-113 and R-114/oil mixtures (opens in a new tab)

  5. Augmentation of in-tube evaporation and condensation with micro-fin tubes using refrigerants R-113 and R-22

    … different micro-fin tubes were studied with R-113 as a test fluid on rather short (i.e., 41 in. or 1.0 m) length test sections. The geometrical parameters investigated were peak shape, valley shape, fin height, number of fins, and spiral angle. The micro-fin tube with 60 spiraled fins of 0.008 …

    iastate Repository record for Augmentation of in-tube evaporation and condensation with micro-fin tubes using refrigerants R-113 and R-22 (opens in a new tab)

  6. Study of two-phase flow patterns and frictional pressure drop in helical and spiral coils

    … pattern and pressure drop for air-water and R113 liquid/vapor flow in helical and spiral coils were conducted. Five test sections, namely, helical coils having a circular cross-section and three rectangular cross-sections of different aspect ratios, along with a circular cross-section spiral …

    ut-knoxville Repository record for Study of two-phase flow patterns and frictional pressure drop in helical and spiral coils (opens in a new tab)

  7. Filmwise condensation on low integral-fin tubes of different diameter

    … were made for filmwise condensation of R-113, steam and ethylene glycol on three sets of finned tubes which differed only in root diameter. The fin root diameters were 12.7 mm. 19.05 mm and 25.0 mm. A comparison of the enhancement ratios (based on constant vapor-side temperature drop) …

    nps Repository record for Filmwise condensation on low integral-fin tubes of different diameter (opens in a new tab)

  8. Effect of vapor velocity during condensation on horizontal finned tubes

    … measurements were made for condensation of R-113 and steam on a smooth tube and on three finned tubes with rectangular shape fins. These tubes had a fin height and width of 1.0 mm and spacings of 0.25, 1.5, and 4.0 mm (tubes A, B, and C respectively) . Data were taken by increasing the vapor …

    nps Repository record for Effect of vapor velocity during condensation on horizontal finned tubes (opens in a new tab)

  9. Condensation of refrigerants on small tube bundles

    … tubes, with two refrigerants, R-114 and R-113. An enhancement ratio of about 2.0 for the overall heat transfer coefficient was demonstrated for the finned tubes over the smooth tubes. Internal contamination, possibly due to a breakdown of the refrigerant molecules when subjected to high …

    nps Repository record for Condensation of refrigerants on small tube bundles (opens in a new tab)

  10. High school sport participation: does it have an impact on physical activity self-efficacy in adolescent males?

    … correlation between PAQ-A and SEPAQ scores, r(113) = .571, p < .01. The regression analysis showed that PAQ-A score significantly predicted SEPAQ scores, b = 10.95, t(113) = 6.63, p < .001. However, school sport participation did not significantly predict SEPAQ scores, b = 0.99, t(113) = 0.97, …

    manitoba Repository record for High school sport participation: does it have an impact on physical activity self-efficacy in adolescent males? (opens in a new tab)

  11. The Risk of the Female Athlete Triad in Collegiate Athletes and Non-Athletes

    … of time spent in exercise in athletes (r=.113, p=.256) and non-athletes (r=-.041, p=.706). When athletes were divided into lean and non-lean athletes statistical significance was found with non-lean (17.4%) sport athletes (χ²(1,N=103)=83.971, p<.01) having a higher overall percentage of …

    utahstate Repository record for The Risk of the Female Athlete Triad in Collegiate Athletes and Non-Athletes (opens in a new tab)

  12. Nucleate pool boiling of high dielectric fluids from enhanced surfaces

    … surface in the nucleate boiling regime in R-113 and FC-72 are presented. Prior to obtaining the data, each of the surfaces was subjected to one of three initial conditions, and the effect of past history on boiling incipience was observed. The data showed that all the surfaces behaved in a …

    nps Repository record for Nucleate pool boiling of high dielectric fluids from enhanced surfaces (opens in a new tab)

  13. La relación entre morfología y vocabulario en niños de 5 y 6 años

    … variables mencionadas. Esto se expresa con r (113) = .4, p< .001. Esta investigación pretende dar a conocer a la comunidad educativa la importancia y el rol de la conciencia morfológica en el aprendizaje de las palabras, pues con ella los niños comprenden los trozos de los términos para …

    upc-peru Repository record for La relación entre morfología y vocabulario en niños de 5 y 6 años (opens in a new tab)

  14. Heat transfer characteristics of simulated microelectronic chips under normal and enhanced conditions

    … with direct immersion cooling in Freon-TF (R-113). The basic heater was 4.5 mm x 4.5 mm electrically heated foil. The studies of plain heaters included natural convection, nucleate boiling, and critical heat flux. Water was included as a working fluid for natural convection. Ultrasonic …

    iastate Repository record for Heat transfer characteristics of simulated microelectronic chips under normal and enhanced conditions (opens in a new tab)

  15. An alternative configuration of Rankine cycle engine-driven heat pump system

    This thesis investigates a new configuration of a heat pump system using a Rankine cycle engine to generate the required power. Presented in this paper is the study of the system's performance behavior with respect to the environmental and operating conditions variation. The objectives are to find …

    ohiolink Repository record for An alternative configuration of Rankine cycle engine-driven heat pump system (opens in a new tab)

  16. Investigation of boiling heat transfer on small diameter tubes and tube bundles

    … of 5.6-32.8 k g/M2 s using distilled water, R-113 and Flutec PPI at nominal atmospheric pressure as the working fluids. Results obtained showed that the heat transfer coefficient was predominantly dependent on the heat flux as opposed to mass flux. Macro scale models were compared with the …

    heriot-watt Repository record for Investigation of boiling heat transfer on small diameter tubes and tube bundles (opens in a new tab)